OPERATING SPECIFICATIONS:
• Capacity: 11,355 litres
• Pressure Requirement: 10-125 psi (0.7 - 8.6 bar), non-shock.
• Temperature: 2-38
O
C
• Flow Rate: 8.3 litres per minute.
GENERAL INSTALLATION / OPERATION/MAINTENANCE
REQUIREMENTS:
• Space required: 51cm x 13cm including 6cm of clear space for cartidge change.
• Install vertically or horizontally with stabilizing support bracket
• Flush new cartridge at full flow for 3 to 5 minutes until air is purged.
• Replace cartridges when capacity is reached, or when flow becomes too slow,
but at least annually.
SPECIAL NOTICES:
• Installation instructions, parts and service availability, and standard warranty
are included with the product when shipped.
• This drinking water system must be maintained according to manufacturer’s
instructions, including replacement of filter cartridges.
• Do not use w
i
th water that is microbiologically unsafe,
or of unknown quality
without adequate disinfection before or after the system.
Systems certified for
cyst reduction may be used on disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by the water treatment
system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under sustained standard laboratory conditions, actual performance may vary.
In�Line Mains Water Filter System
WFA HIFLOW INLINE MAINS WATER FILTER SYSTEM
Model No. WFA HIFLOW
Important Notice:
Read this performance data sheet and compare the capabilities of this
unit with your actual water treatment needs.
FEATURES:
• Finely polishes treated water to premium quality for drinking and cooking.
• Reduces chlorine taste and odour.
• Reduces dirt, rust, asbestos fibres and other particulates such as oxidized iron,
manganese, and sulphides.
• Reduces parasitic protozoan cysts such as
Giardia, Entamoeba and
Cryptosporidium.
• Absorbs common earthy, mouldy, fishy tastes and odours.
• Reduces limescale build up in water using appliances.
HEALTH CLAIM PERFORMANCE CLASSIFIED BY UL.
This system has been tested according to NSF/ANSI 42 and 53
for the reduction of the substances listed below
The concentration of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissable limit for water
leaving the system, as specified in NSF/ANSI 42 and 53
Influent Challenge
Concentration
2.0 mg/L + 10%
at least 10,000
particles/mL
Minimum 50,000/L
0.15 mg/L + 10%
0.15 mg/L + 10%
11+ 1 NTU
†
Max. Permissible
Product Water
Concentration
0.010 mg/L
0.010 mg/L
0.5 NTU 1
Reduction
Requirements
>50%
> 85%
99.95%
Minimum
Reduction
99.99%
94.1%
98.9%
98%
Average
Requirements
98%
99.8%
99.99%
97.2%
98.9%
99%
Substance
Standard 42 - Aesthetic Effects
Chlorine
Particulate
Class 1 particles
0.5 to < 1 um
Standard 53 - Health Effects
Cyst
Lead 8.5
Lead 6.5
Turbidity
_________________________________________________________________________________________________________________________
†
NTU= Nephelometric Turbidity Units.
Performance