background image

User guide

 886E - WIFI Version

8

  

 Additional information

Replacing the remote control 

In the case of loss or failure, to replace a remote control that has already been synchronized with a control panel,take the following 

steps: First, push the 

Program

 button on the control panel to activate Program mode. The control panel is in Program Mode when 

the first LED is flashing. When the first led flashes, After push the 

Reset

 button on the control panel three times. The first three LEDs 

should start to flash. Unit is ready to receive a syncronization signal from a remote control.

Replacing  or adding a water sensor

Set the Main Control to Program Mode by pressing the 

Program

 button. The first LED will flash. Push the 

Open

 button on the 

remote control – each push will move the flashing LED to the next position. When the desired position is reached, synchronize the new 

sensor by shorting the electrodes as described previously. The selected LED should now be continuously lit, and the next one, flashing.

Battery replacement

Sensors 

The water sensors are equipped with two 3V/20mm lithiumcoin cells (ex.: Panasonic CR2032). 

To replace, open the sensor case by removing one fixing screw, remove old batteries and replace 

with new – carefully observing marked polarity (Positive upward). Replace the cover and 

return to service. (Note: the sensor will function with only one battery in place, with reduced 

lifetime.)

Remote control 

The Remote Control is equipped with one 3V / 16mm lithium coin cell  

(ex.: Panasonic CR-1632). The case snaps open with a fingernail.

Control Panel 

The control panel is equipped with one 9V Battery  (ex.: Energizer EN22). To replace, slide out the access hatch from control panel, 

remove the old battery and insert the new, then replace the cover.

Alarms of the control panel

The control panel has 20 numbered LED indicators. These show 

green

 when there are no anomalies. If one or more sensors fail, or 

detect water, the corresponding LED will light 

red

, the valve will close and you will hear an alarm.

Sensor Low Battery  

If a water sensor has low battery, it periodically sends a signal to the control panel. The corresponding LED on the control panel will 

show 

orange

, and the audible alarm will sound, and continue for 15 minutes. The LED will remain 

orange

 until the condition is 

rectified. Water will shut off  after 4 low battery signals have been received.  The system also outputs a relay contact to remote alarm 

system if a low battery alarm occurs. The battery of the corresponding sensor must be replaced, though it should continue to function 

for some time. Battery life should be in excess of one year.

Water detection 

If any sensor detects water, the corresponding LED will light 

red

 and the audible alarm sound. The valve will immediately close, and 

remain closed until opened with the remote or until the 

Reset

 button is pressed.

It is best to change 

batteries every 12 months.

Batteries should be 

changed if the sensors 

have been activated 

when water is detected.

Summary of Contents for LED 13

Page 1: ...ater damages Our vision To be the world leader in prevention systems to prevent water damage in residential industrial and commercial areas Our mission To provide a product assuring peace of mind and...

Page 2: ...installed Complete water cut off system with 2 years guarantee that is certified CSA and UL with audit by Intertek every three months Audible alarm for 15 minutes in situation of detection or problem...

Page 3: ...ingertips A fully autonomous automated and connected solution against water damage Recognized by the majority of insurers Our smart valve stops the water flow in the following second avoiding any exce...

Page 4: ...e number at the bottom of the page They will then guide you through the process of sending the defective part with a Return Merchandise Authorization RMA number Technical support 24 7 1 833 487 7997 W...

Page 5: ...em Synchronizing and functioning After the initial power up all the LEDs on the the 886E control will flash This indicates that no control devices have yet been synchronized paired to the unit This sy...

Page 6: ...nsors must be synchronized to the control box To synchronize a sixth sensor press the synchronization button six times slowly until the sixth light on the control box flashes Make sure the indicator l...

Page 7: ...with concrete is provided in the box Drill as close to water lines as possible making sure you do not damage them Fix the sensor in the hole If you decide to cover the hole use a grid to allow water t...

Page 8: ...AP Enter the password waterprot886 Once connected open a web browser and visit the address 192 168 4 1 Check that the 16 characters on the screen correspond to the 16 characters of the serial number o...

Page 9: ...ged in The control circuit will issue an alarm if a valve becomes disconnected In the event that only one valve is deployed a dummy plug must be inserted in the other jack Alarm system connection For...

Page 10: ...ced lifetime Remote control The Remote Control is equipped with one 3V 16mm lithium coin cell ex Panasonic CR 1632 The case snaps open with a fingernail Control Panel The control panel is equipped wit...

Page 11: ...ontrol panel is equipped with a tempereature sensor Should the ambient temperature drop to near freezing levels 5 degrees Celsius the valve will be closed and remain so until the system is reset The b...

Page 12: ...use it again in case you add twin sensors for example Inventory Sheet 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 List of strategic location to protect Kitchen sink dishwasher refrigerator conn...

Page 13: ...ever they can be as long as you need Valves Valves of more than 1 inch they must be equipped with an booster relay Artesian well pump Additional accessories are available to ensure that the system fun...

Page 14: ...2014 A 24 7 helpline 1 833 487 7997 Get more information on service contract We take care of changing batteries at the right time and we recertify the installation annually We also offer a certified...

Page 15: ...ditions on a yearly basis for all units in the building when they provide a rebate or lower deductible As far as operation costs is concerned there will be no charge for the first 2 years since each c...

Page 16: ...ou be able to provide any references We performed more than 5000 installations in different segments with an average of 7 sensors per installation Where do you place the smart valves in a multi family...

Page 17: ...each building for central messaging to maintenance manager for single or multiple buildings including data reporting The cost of this option can vary from building to building and requires on site tes...

Reviews: