User guide
886E - WIFI Version
9
IOK Signal Loss
When water sensors are present and working, they send an IOK (I’m OK) signal 6 times a day (every 4 hours). In view of the fact that
these signals are brief so as to conserve battery power, sometimes they may not be received due to interference or signal overlaps.
If three consecutive signals are missed, after 12 hours the relevant LED flashes
green
. If six consecutive signals are missed over
24 hours, the LED flashes
red
, an alarm is registered, and the valve is closed. If an IOK signal is received at any time during this
24 hour period, the software resets and the flashing
green
is cancelled.
Power Loss
The control panel is equipped with a 9V standby battery. This allows operation to continue during power outages. The control panel
indicates power loss by a
red
flashing battery light. If the local standby battery reaches a critically low level, the valve will close and
remain so until the battery is replaced and the system is
reset
.
Low temperature Alarm
The control panel is equipped with a tempereature sensor. Should the ambient temperature drop to near-freezing levels (5 degrees
Celsius), the valve will be closed, and remain so until the system is reset. The battery/temperature LED should show
orange
.
Fault Responses
Occurrence
Test Period
LED Display
Position
Colour
Audible
Alarm
Action
None
S.O.
Steady
All
Green
None
None
Water Detected
Immediate
Steady
Fault location
Red
1/2 s On
1/2 s Off
Close valve
Sensor low battery
Signal
12 hours
Steady
Fault location
Orange
Bip 1/4 s
toutes les 10 s
None
After 4 consecutive
low battery signals
48 hours
Steady
Fault location
Orange
1/2 s On
1/2 s Off
Close valve
IOK signal
(3 signals missed)
12 hours
Flashing
Fault location
Green
None
None
After 2 consecutive
(6 signals missed)
24 hours
Flashing
Fault location
Red
1/2 s On
1/2 s Off
Close valve
AC Power Outage
(Rxon battery)
Flashing
Temp/Battery*
Green
None
None
Rx Battery Low
Flashing
Temp/Battery*
Red
None
Close valve
Low temperature
Steady
Temp/Battery
Orange
None
Close valve
Valve opened
Steady
Open/Close
Green
None
Valve closed
Steady
Open/Close
Red
None
Valve disconnected
Flashing
Open/Close
Orange
1/2 s On
1/2 s Off
*Position LEDs OFF to conserve power