Synchronizing and functioning 

(continued)

Synchronizing the sensors

Once all the sensors and the remote control are synchronized placed, and the valve installed. The 

LEDs on the control panel should show 

green

 for each sensor installed. Sensors can be tested 

by shorting the electrodes as described above. After a short delay an alarm will be heard from the 

control panel, and the activated sensor’s LED should turn 

red

.

The basic Water-Protec kit includes 5 sensors but it is possible to add as many as needed. If you 

need more sensors than available positions you can use 

twin sensors

. Twin sensors can occupy the 

same position on the control box.

Press the metal portion of the tester tool onto the two metal 

contacts of the sensor. If the sensor is functional, a light 

will come on the control box and the valve will close. Note 

the position of the sensor on the control box and identify the sensor with the corresponding 

numbered sticker. This is an important step. It will allow you to quickly identify the source of a 

leak in case of water damage.

The next position on the control box will be automatically selected to allow you to synchronize the 

next sensor. If you use twin sensors, only one of the two sensors must be associated with the tester 

tool for the pair to be synchronized.

Before usage, the additional sensors must be synchronized to the control box. To synchronize a sixth sensor press the synchronization 

button six times slowly until the sixth light on the control box flashes. Make sure the indicator light changes position before pressing 

the button between each position. The synchronization mode will automatically turn off after 15 seconds of inactivity. Remember to 

identify sensors using the corresponding numbered sticker.

If you want to add sensors at a later time, refer to the

 inventory sheet

 to find a free position. The inventory sheet is at the end of  

this guide.

Valve Installation

Now that all the necessary tests are done and that the sensors are correctly 

synchronized and identified, you can install the valve.

First, find an installation 

point for the valve. 

It must be located 

immediately after the residence’s main 

water supply and, where applicable, 

before the junction of the outdoor 

sprinklers. 

In order to power the control panel, 

an electrical outlet must be available 

nearby (gauge #24).

 

Close the circuit breakers for appliances connected to a 

water supply and the water heater. Close the water inlet.

Empty the water pipes by opening a tap at the lowest  

point of the residence. If necessary, also open the bathtub 

at the highest point of the residence. Once the pipes  

have been emptied, turn off the tap at the lowest point  

of the property.

Make sure that the diameter 

of the valve matches the 

water inlet hose and use the 

appropriate fittings for your 

piping.

For a valve of 

more than  

1 inch,

 it must be 

equipped with a 

 

booster relay

Summary of Contents for LED 13

Page 1: ...ater damages Our vision To be the world leader in prevention systems to prevent water damage in residential industrial and commercial areas Our mission To provide a product assuring peace of mind and...

Page 2: ...installed Complete water cut off system with 2 years guarantee that is certified CSA and UL with audit by Intertek every three months Audible alarm for 15 minutes in situation of detection or problem...

Page 3: ...ingertips A fully autonomous automated and connected solution against water damage Recognized by the majority of insurers Our smart valve stops the water flow in the following second avoiding any exce...

Page 4: ...e number at the bottom of the page They will then guide you through the process of sending the defective part with a Return Merchandise Authorization RMA number Technical support 24 7 1 833 487 7997 W...

Page 5: ...em Synchronizing and functioning After the initial power up all the LEDs on the the 886E control will flash This indicates that no control devices have yet been synchronized paired to the unit This sy...

Page 6: ...nsors must be synchronized to the control box To synchronize a sixth sensor press the synchronization button six times slowly until the sixth light on the control box flashes Make sure the indicator l...

Page 7: ...with concrete is provided in the box Drill as close to water lines as possible making sure you do not damage them Fix the sensor in the hole If you decide to cover the hole use a grid to allow water t...

Page 8: ...AP Enter the password waterprot886 Once connected open a web browser and visit the address 192 168 4 1 Check that the 16 characters on the screen correspond to the 16 characters of the serial number o...

Page 9: ...ged in The control circuit will issue an alarm if a valve becomes disconnected In the event that only one valve is deployed a dummy plug must be inserted in the other jack Alarm system connection For...

Page 10: ...ced lifetime Remote control The Remote Control is equipped with one 3V 16mm lithium coin cell ex Panasonic CR 1632 The case snaps open with a fingernail Control Panel The control panel is equipped wit...

Page 11: ...ontrol panel is equipped with a tempereature sensor Should the ambient temperature drop to near freezing levels 5 degrees Celsius the valve will be closed and remain so until the system is reset The b...

Page 12: ...use it again in case you add twin sensors for example Inventory Sheet 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 List of strategic location to protect Kitchen sink dishwasher refrigerator conn...

Page 13: ...ever they can be as long as you need Valves Valves of more than 1 inch they must be equipped with an booster relay Artesian well pump Additional accessories are available to ensure that the system fun...

Page 14: ...2014 A 24 7 helpline 1 833 487 7997 Get more information on service contract We take care of changing batteries at the right time and we recertify the installation annually We also offer a certified...

Page 15: ...ditions on a yearly basis for all units in the building when they provide a rebate or lower deductible As far as operation costs is concerned there will be no charge for the first 2 years since each c...

Page 16: ...ou be able to provide any references We performed more than 5000 installations in different segments with an average of 7 sensors per installation Where do you place the smart valves in a multi family...

Page 17: ...each building for central messaging to maintenance manager for single or multiple buildings including data reporting The cost of this option can vary from building to building and requires on site tes...

Reviews: