INSTALLATION
GENERAL INSTALLATION & SERVICE WARNINGS
The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There is a small amount of “give” to properly
connect the piping, but the water treatment unit is not designed to support the weight of the plumbing.
Do not use Vaseline, oils, other hydrocarbon lubricants, or spray silicone anywhere. A silicone lubricant may be used on black “O” Rings, but is not
necessary.
Avoid any type of lubricants, including silicone, on red or clear lip seals.
Do not use pipe dope or other sealants on threads.
Teflon® tape must be used on the threads of the 1” NPT inlet and outlet and on the threads for
the drain line connection. Teflon® tape is not used on the nut connections or caps because “O” Ring seals are used. The nuts and caps are designed
to be unscrewed or tightened by hand or with the special plastic Service Wrench, #CV3193-02. If necessary, pliers can be used to unscrew the nut or
cap. Do not use a pipe wrench to tighten nuts or caps.
Do not place screwdriver in slots on caps and/or tap with a hammer.
SITE REQUIREMENTS
• Water pressure – 30-100 psi
• Current draw is 0.5 amperes
• Water temperature – 33-100°F (0.5-37.7°C)
• The plug-in transformer is for dry locations only
• Electrical – 115/120V, 60Hz uninterrupted outlet
WELL WATER INSTALLATION
MUNICIPAL INSTALLATION
1. The distance between the drain and the water conditioner should be as short as possible (see #9).
2. Since salt must be added periodically to the brine tank, it should be in an easily accessible location.
3. The media tanks should be installed on a firm, level surface (above or below grade).
4. It is NOT recommended to install any water treatment unit with less than 10 feet of piping between its outlet and the inlet of a water heater.
CAUTION: To protect the unit in the event of a hot water heater backup, the manufacturer recommends the use of an expansion tank
on the outlet side of the unit (see diagram).
5. Do not locate unit where it or its connections (including the drain and overflow lines) will ever be subjected to temperatures under 33°F.
6. Do not subject the tank to any vacuum as this may cause an “implosion” and could result in leaking. If there is a possibility a vacuum could
occur, please make provision for a vacuum breaker in the installation.
7.
INLET/OUTLET PLUMBING:
Be sure to install Bypass
Valve onto main control valve before beginning plumbing.
(See installation picture to right. Be sure bypass is
connected to treated water inlet and outlet.)
If it is
desired to bypass outside hydrants, a cold water kitchen
sink, or other locations, provisions should be made at this
time. Install an inlet shutoff valve and plumb to the unit’s
bypass valve inlet located at the right front as you face the
unit. There are a variety of installation fittings available.
They are listed under the Installation Fitting Assemblies
section of the manual. When assembling the installation
fitting package (inlet and outlet), connect the fitting to the
plumbing system first and then attach the nut, split ring
and “O” Ring. Heat from soldering or solvent cements may
damage the nut, split ring or “O” Ring. Solder joints should be cool and solvent cements should be set before installing the nut, split ring
and “O” Ring. Avoid getting solder flux, primer, and solvent cement on any part of the “O” Rings, split rings, bypass valve or control valve. If the
building’s electrical system is grounded to the plumbing, install a copper grounding strap from the inlet to the outlet pipe. Plumbing must be done
in accordance with all applicable local codes.