background image

3

SECTION I.      INTRODUCTION 

   Your new Reverse Osmosis (R.O.) Drinking Water 

System uses a combination of fi ltration tech nol o gies 
to reduce unwanted contaminants in a water supply. 
The following steps combine to give you the best in 
clear sparkling drinking water: 

    

MECHANICAL FILTRATION/ACTIVATED 
CARBON

–The Sediment/Carbon Module will 

remove the larger particles such as silt, rust 
and scale. Its 5 micron (equal to 0.0002 inch) 
nominal rating helps to give maximum life to the 
R.O. Membrane. The activated carbon in the 
Prefi lter will remove any chlo rine that may be 
present in the feed water. This pre treat ment is 
also necessary for membrane protection.

    

REVERSE OSMOSIS MEMBRANE

–The R.O. 

Membrane is the heart of the fi l tra tion system. 
It is designed to reduce the dis solved min er al 
content of the water. Minerals picked up in the 
environment by the water are measured as Total 
Dissolved Solids (TDS). In the Reverse Os mo sis 
process, dissolved minerals are sep a rat ed from 
the incoming water (Feed Water) to produce 
the product wa ter (the Permeate). The excess 
minerals are rinsed to drain (the Reject Water). 

    The membrane is a specially con struct ed, fully 

aromatic polyamide fi lm, and is classifi ed as a 
Thin Film Composite (T.F.C.).

    The spiral wound construction of the R.O. 

Membrane provides maximum surface area 
for water production and is less susceptible 
to fouling by par tic u late matter, turbidity and 
colloidal ma te ri als. 

    

ACTIVATED CARBON

–The Ac ti vat ed Carbon 

Module contains carbon particles with a vast 
network of pores. The tremendous surface 
area of these pores (typically 800–1200 square 
meters per gram of carbon) gives the carbon 

very good adsorptive sites for sub stanc es that 
contribute to tastes and odors. 

    

IN–LINE ACTIVATED CARBON POST FILTER

The In–Line Activated Carbon Post Filter is 
located after the Holding Tank and reduces the 
tastes and odors that may pass through the 
system. It adds a fi  nal polish to the water. 

    

AUTOMATIC SHUTOFF VALVE

–The ASO Valve 

senses when the Holding Tank is full and closes 
the feed water supply to prevent excess reject 
water from going to drain when the unit is not 
producing water.

    

WATER QUALITY MONITOR

–The Water Quality 

Monitor has been integrated into the faucet 
base for instant monitoring at the touch of a 
button. The monitor compares the level of the 
Total Dissolved Solids in the incoming (feed) 
water versus the product water and calculates 
the percent rejection. The monitor is preset to 
indicate a level of 75% rejection. 

     A green light indicates that the percent rejection 

is at or above the set (desired) value and that 
the system is producing quality water. 

     An amber light indicates that the product water 

quality is less than acceptable. Because the 
Water Quality Monitor was designed to operate 
best while the system is making water, a false 
reading may occur if tested when your R.O. 
drinking water system is not making water. 
Please empty the Holding Tank, wait 15 minutes 
for the system to begin making water, and test 
your water quality again. If the Water Quality 
Monitor light is still amber, please contact a 
water treatment professional for service. The 
Water Quality Monitor requires a 9 volt battery, 
which is included.

IMPORTANT NOTICES:

This reverse osmosis system contains replaceable treatment components critical for effective performance. It is the user's 
responsibility to, and the manufacturer strongly recommends that the user, periodically test the product water to verify the 
system is performing satisfactorily. See the test kit(s) for sampling instructions.

This system is acceptable for treatment of infl uent concentrations of no more than 27 mg/l nitrate and 3 mg/l nitrite in 
combination measured as N and is certifi ed for nitrate/nitrite reduction only for water supplies with a pressure of 40 psig 
(280 kPa) or greater. 

This system conforms to NSF/ANSI Standard 58 for pentavalent arsenic reduction. See the Performance Data Sheet and 
Arsenic Facts section for an explanation of reduction performance.

DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY, WITHOUT 
ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM.

 Systems certifi ed for cyst reduction may be used on 

disinfected water that may contain fi lterable cysts. 

Summary of Contents for ECLIPSE WRO-35

Page 1: ...58 for the reduction of the claims specified on the Performance Data Sheet E C L I P S E Reverse Osmosis Drinking Water System from Water Right Sold and serviced by authorized Water Right dealers Ins...

Page 2: ...infection with Cryptosporidium from drinking water This guidance pertains to people with HIV AIDS patients receiving treatment for cancer recipients of organ or bone marrow transplants transplant pati...

Page 3: ...the feed water supply to prevent excess reject water from going to drain when the unit is not producing water WATER QUALITY MONITOR The Water Quality Monitor has been integrated into the faucet base...

Page 4: ...n figures are for a new Membrane that has been rinsed for 24 hours The production rate of a new Membrane can decrease by 10 per year or more depending upon the scaling and fouling tendencies of the Fe...

Page 5: ...ation may include wood screws or machine screws and nuts for mounting the manifold or concrete anchors for hanging on basement wall Additional tubing or tube connectors Plastic wire ties for organizin...

Page 6: ...ADDLE VALVE COLD WATER LINE ONLY 1 AIR GAP REQUIRED MOUNT HOLDING TANK ON SHELF OR STRAP BETWEEN FLOOR JOISTS Shelf Or Straps Not Included FLOOR BASEMENT FLOOR NOTE FOR REFRIGERATOR WATER DISPENSER OR...

Page 7: ...illing of water pitchers and glasses and an open area beneath the faucet under the sink for attaching product and drain tubing are considerations A 2 diameter flat surface is required above and below...

Page 8: ...chipping Drill a pilot hole for the porcelain cutter Use the pilot drill supplied with the kit or a carbide tipped drill When drilling the 1 hole drill slowly and carefully the porcelain chips easily...

Page 9: ...ain Tubing Allow space for thickness of Mounting Surface and Slotted Washer Plastic Spacer Spout Plastic Shipping Plug Remove 7 16 Stud Mounting Surface 1 drill hole 7 16 Washer 7 16 Hex Nut 3 8 Polyt...

Page 10: ...e Feed Water Saddle Valve on the tubing for 3 8 OD tubing use the back plate side with the small groove to prevent distortion of the tubing for larger tubing up to 5 8 OD use the large groove of the b...

Page 11: ...r a trash compactor may require special fabrication of a mounting plate 1 The mounting bracket will accept either 10 or 12 5mm mounting screws spaced on 6 15 cm centers Allow at least 4 10 cm of clear...

Page 12: ...Blue Polytube where it would be convenient to install and change the In Line Filter Make a clean straight cut to insure proper connections The Out port on the In Line Filter should be towards the fau...

Page 13: ...t 8 hours before emptying each tank When the Faucet is first opened expect air and carbon fines very fine black powder from the In Line and Activated Carbon Post Filters to be rinsed out This is norma...

Page 14: ...olding Tank to the Tee see Fig 1 page 5 Put 50 drops of bleach this is tsp or 3 ml into the tubing and reconnect it to the Tee NOTE Now is the convenient time to change the In Line Activated Carbon Po...

Page 15: ...es 2 5 oz 2 min 1 25 oz min 1 25 oz min x 11 2 14 gpd The Reject Ratio is the amount of water produced compared to the amount of water flowing to drain Reject Ratio Reject Rate_ Product Rate EXAMPLE T...

Page 16: ...m of TDS would exert a backward pressure of about 15 psig on the membrane Net Pressure Differential Feed Water Pressure Holding Tank Pressure Osmotic Pressure The higher the net pressure differential...

Page 17: ...101 4 31 9 120 7 37 0 140 0 42 1 159 3 47 2 178 7 500 14 3 54 1 19 4 73 4 24 5 92 7 29 6 112 0 34 7 131 3 39 8 150 6 44 9 169 9 1000 11 7 44 3 16 9 64 0 22 0 83 3 27 1 102 6 32 2 121 9 37 3 141 2 42...

Page 18: ...f Membrane life is unusually short find and correct the problem Replace Membrane Feed Water Saddle Valve is plugged or closed Clogged Sediment Carbon Module or Activated Carbon Module Low water pressu...

Page 19: ...ion Tastes and odors in the Product Water The Product Water and Drain Water lines are reversed No drain flow Drain Restrictor is clogged No drain flow the drain orifice in the Air Gap Faucet is plugge...

Page 20: ...20 NOTES...

Page 21: ...21 MADE IN USA EXPLODED VIEW PARTS LIST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 19 18 15 16 21 Nitrate Nitrite Test Kit...

Page 22: ...in Restrictor 80 GPD 303 lpd Blue 17 S7125X Activated Carbon Module 18 S1405 1 4 3 8 Fitting Wrench 19 S3072 Wrench for Housing 20 S7206W In Line Activated Carbon Post Filter 21 S1447 Nitrate Nitrite...

Page 23: ......

Page 24: ...also pay for shipping or travel charges to return the defective part s What Does This Warranty Not Cover This warranty does not cover the disposable sediment and carbon filters whose service life dep...

Reviews: