Troubleshooting 

 

1. Softener Fails To Regenerate.  

A. Electrical service to unit has been 
interrupted. 

A. Assure permanent electrical service (check fuse, 
plug, pull chain or switch). 

 

B. Timer programming bad (improper 
programming). 

B. Check programming and reset as needed. 

 

 

 

2. Softener Delivers Hard Water.  

A. By-pass valve is open. 

A. Close by-pass valve. 

 

B. No salt in brine tank. 

B. Add salt to brine tank and maintain salt level 
above water level. 

 

C. Injectors or screen plugged. 

C. Clean or replace injectors and screen. 

 

D. Insufficient water flowing into brine 
tank. 

D. Check brine tank fill time and clean brine line 
flow if plugged. 

 

E. Hot water tank hardness. 

E. Repeated flushings of the hot water tank is 
required. 

 

F. Flow meter jammed. 

F. Check flow indicator light for flow. Remove 
obstruction from flow meter. 

 

G. Flow meter cable disconnected or 
not plugged into meter. 

G. Check meter cable connection to timer and 
meter. 

 

H. Improper programming. 

H. Reprogram the control to the proper 
regeneration type, inlet water hardness, capacity or 
flow meter size. 

 

I. Plugged brine line or air check. 

I. Remove and clean any sediment from brine tank 
and brine valve assembly. 

 

J. Salt bridge has formed.  

J. Refer to 

Breaking a Salt Bridge 

section in 

manual. 

 

K. No water in brine tank.  

K. Ensure safety float is not stuck. 

 

L. Unit is plumbed backwards.  

L. Check that the unit is plumbed correctly. 

 

M. Water hardness has increased or is 
set incorrectly. 

M. Retest hardness and change settings 

 

N. Water pressure is too low.  

N. Line pressure must be at least 20psi. 

 

 

 

3. Unit Uses Too Much Salt.  

A. Improper salt setting. 

A. Check salt usage and salt setting. 

 

B. Excessive water in brine tank. 

B. See problem No. 7. 

 

C. Improper programming. 

C. Check programming and reset as needed. 

 

 

 

4. Loss of Water Pressure.  

A. Iron buildup in line to water 
conditioner. 

A. Clean line to water conditioner. 

 

B. Iron buildup in water conditioner. 

B. Clean control and add resin cleaner to resin bed. 
Increase frequency of regeneration. 

 

 

 

5. Loss of Resin Through Drain 
Line.  

A. Air in water system. 

A. Assure that well system has proper air eliminator 
control and check for dry well condition. 

 

B. Drain line flow control is too large. 

B. Ensure drain line flow control is sized correctly. 

 

 

 

6. Iron in Conditioned Water.  

A. Fouled resin bed. 

A. Check backwash, brine draw and brine tank fill. 
Increase frequency of regeneration. Increase 
backwash time. 

 

B. Iron content exceeds recommended 
parameters. 

B. Add iron removal from filter or system. 

 

 

 

Summary of Contents for FF-948-M

Page 1: ...INSTALLATION MANUAL WATER SOFTENER SYSTEMS FLEET FARM WATER SOFTENER FLEET FARM WATER TREATMENT 1900 PROSPECT CT APPLETON WI 54914 1 800 777 1426PH 920 739 9406 FAX...

Page 2: ...5 HARDNESS SETTING 5 INSTALLATION 5 CONTROL START UP PROCEDURES 9 SOFTENER OPERATION 10 1 BRINE DRAW SLOW RINSE POSITION 11 2 BACKWASH POSITION 11 3 FAST RINSE POSITION 11 4 BRINE FILL 11 5 SERVICE 1...

Page 3: ...eatment system Always connect the Fleet Farm Water Treatment system to the main water supply pipe before water heater Do not expose Fleet Farm Water Treatment system to freezing temperatures Water fre...

Page 4: ...2 0 FFE 1054 M Red fine resin 24 600 6 1 4 0 26 800 9 3 2 9 33 400 15 9 2 1 7 5 0 3 2 5 2 6 5 15 0 2 0 FFC 835 M Red resin 9 700 3 2 3 1 13 800 6 1 2 3 19 800 9 3 2 1 7 1 0 5 0 7 1 9 0 14 4 1 5 Cont...

Page 5: ...Fleet Farm Water Treatment system after the pressure tank but before the water heater Install the Fleet Farm Water Treatment system where it will not be subject to temperatures outside of the limits s...

Page 6: ...tlet plumbing in some manner use pipe hangers to keep the weight off of the valve fittings Perform steps 6 9 to install flexible drain hose Skip to step 10 to install rigid drain pipe 6 Find barbed fi...

Page 7: ...g Figure 4 11 Take the other half of the cut hose and attach it to the overflow adapter elbow located on the side of the brine tank Use a hose clamp to hold it in place Locate the other end of the hos...

Page 8: ...flush and condition your water softener a Add 1 1 2 ounces of common household bleach to the water in the cabinet brine tank b Following the directions in the Control Service Manual manually advance t...

Page 9: ...e most effective setting for your particular model All softeners are set for a medium capacity salt setting which can be found under CAPACITY PERFORMANCE SPECIFICATIONS on Page 2 Check Salt Setting Ch...

Page 10: ...dule Water softener start up NOTE The various regeneration positions may be set manually by turning the MANUAL REGENERATION KNOB on the front of the control in a clockwise direction until the POSITION...

Page 11: ...to the drain 3 Brine Draw Slow Rinse Position Brine Draw is the process in which brine is drawn out of the brine cabinet and passed through the resin in a downward direction This rinses the resin and...

Page 12: ...hru the top of tank passage around the upper piston groove and out the drain line 2 Pre Rinse 5 minutes Hard water enters the unit at the valve inlet flows around the lower piston groove down thru the...

Page 13: ...LEY Hard water enters the unit at the valve inlet flows around the lower piston groove down thru the top of tank passage downward thru the resin up the distributor tube thru the center hole in the pis...

Page 14: ...isconnect brine tube and drain line connections at the injector body 5 Remove the two injector body mounting screws The injector and brine module can now be removed from the control valve Clean and re...

Page 15: ...and brine valve assembly J Salt bridge has formed J Refer to Breaking a Salt Bridge section in manual K No water in brine tank K Ensure safety float is not stuck L Unit is plumbed backwards L Check t...

Page 16: ...ed B Clean or replace injectors C Improper programming C Check programming and reset as needed D Line pressure is too low D Increase line pressure line pressure must be at least 20psi at all times 10...

Page 17: ...13312 Spring Idler 9 1 13164 Drive Gear 10 1 13299 Curved Washer 11 1 13170 Main Gear Shaft 12 1 1 D09 24 Hour Gear 13 1 13802 Cycle Actuator Gear 14 1 14177 Knob Manual Regeneration 15 2 13300 Ball...

Page 18: ...eI Beige 1 14207 Knob LabeI Silver control valve assembly time clock control valve body assembly ITEM NO 1 2 3 4 NO REQ D 2 5 1 1 1 1 PART NO 13255 13242 14449 14450 13304 10244 DESCRIPTION Adapter Cl...

Page 19: ......

Page 20: ...Fleet Farm Water Softeners Manufactured By Water Right Inc 1900 Prospect Ct Appleton WI 54914 800 777 1426 Ph 920 739 9406 Fax mail water right com...

Reviews: