background image

 

 

Setup 

 
Unpacking and Inspection 

Check the 

Fleet Farm Water Treatment 

system components for damage or missing parts. 

 
 
Where to Install the Softener 

Consider the following points when determining where to install the water softener: 

 

Place the 

Fleet Farm Water Treatment 

system as close as possible to a sewer drain. 

 

Do not install the softener where it would block access to the water heater, or access to the main water shutoff, 
water meter, or electrical panels.

  

 

Keep outside faucets on hard water to save soft water and salt. 

 

Install the softener in a place where water damage is least likely to occur if a leak develops. 

 

A 120V electrical outlet is needed to plug in the transformer. If the outlet is remote (up to 100 feet), use 18 gauge 
wire to connect. 

 

Always connect the 

Fleet Farm Water Treatment 

system to the main water supply pipe before the water heater. 

 

If using well water, always install the

 Fleet Farm Water Treatment

 system after the pressure tank, but before the 

water heater. 

 

Install the 

Fleet Farm Water Treatment 

system where it will not be subject to temperatures outside of the limits 

stated in the Specification section or to direct sunlight. 

 

 
 
 
Hardness Setting 

 

Municipal Water 
Fleet Farm 

recommends that you bring in a sample of water in to be tested. Fleet Farm personnel will test your water 

free of charge. Or call your local water company to determine your water hardness in grains per gallon and iron in 
mg/l (or ppm). 

 

 

Well Water 

Again,

 Fleet Farm 

recommends you bring a sample to the store to be tested or have your water tested professionally 

for accurate hardness and iron content.  

 
 
Installation  

 

1.  Turn off gas or electric supply to the water heater. 
 
2.  Turn off the water supply to pipes to be cut and drain the house water pipes. 
 
3.  Open both hot and cold faucets. 
 
4.  Move the softener assembly into installation position.   

 

Be sure the installation surface is level and smooth. 

 

Provisions should be made to by pass outside faucets.  

 
5.  Plumb IN and OUT connections to and from softener.  

Summary of Contents for FF-948-M

Page 1: ...INSTALLATION MANUAL WATER SOFTENER SYSTEMS FLEET FARM WATER SOFTENER FLEET FARM WATER TREATMENT 1900 PROSPECT CT APPLETON WI 54914 1 800 777 1426PH 920 739 9406 FAX...

Page 2: ...5 HARDNESS SETTING 5 INSTALLATION 5 CONTROL START UP PROCEDURES 9 SOFTENER OPERATION 10 1 BRINE DRAW SLOW RINSE POSITION 11 2 BACKWASH POSITION 11 3 FAST RINSE POSITION 11 4 BRINE FILL 11 5 SERVICE 1...

Page 3: ...eatment system Always connect the Fleet Farm Water Treatment system to the main water supply pipe before water heater Do not expose Fleet Farm Water Treatment system to freezing temperatures Water fre...

Page 4: ...2 0 FFE 1054 M Red fine resin 24 600 6 1 4 0 26 800 9 3 2 9 33 400 15 9 2 1 7 5 0 3 2 5 2 6 5 15 0 2 0 FFC 835 M Red resin 9 700 3 2 3 1 13 800 6 1 2 3 19 800 9 3 2 1 7 1 0 5 0 7 1 9 0 14 4 1 5 Cont...

Page 5: ...Fleet Farm Water Treatment system after the pressure tank but before the water heater Install the Fleet Farm Water Treatment system where it will not be subject to temperatures outside of the limits s...

Page 6: ...tlet plumbing in some manner use pipe hangers to keep the weight off of the valve fittings Perform steps 6 9 to install flexible drain hose Skip to step 10 to install rigid drain pipe 6 Find barbed fi...

Page 7: ...g Figure 4 11 Take the other half of the cut hose and attach it to the overflow adapter elbow located on the side of the brine tank Use a hose clamp to hold it in place Locate the other end of the hos...

Page 8: ...flush and condition your water softener a Add 1 1 2 ounces of common household bleach to the water in the cabinet brine tank b Following the directions in the Control Service Manual manually advance t...

Page 9: ...e most effective setting for your particular model All softeners are set for a medium capacity salt setting which can be found under CAPACITY PERFORMANCE SPECIFICATIONS on Page 2 Check Salt Setting Ch...

Page 10: ...dule Water softener start up NOTE The various regeneration positions may be set manually by turning the MANUAL REGENERATION KNOB on the front of the control in a clockwise direction until the POSITION...

Page 11: ...to the drain 3 Brine Draw Slow Rinse Position Brine Draw is the process in which brine is drawn out of the brine cabinet and passed through the resin in a downward direction This rinses the resin and...

Page 12: ...hru the top of tank passage around the upper piston groove and out the drain line 2 Pre Rinse 5 minutes Hard water enters the unit at the valve inlet flows around the lower piston groove down thru the...

Page 13: ...LEY Hard water enters the unit at the valve inlet flows around the lower piston groove down thru the top of tank passage downward thru the resin up the distributor tube thru the center hole in the pis...

Page 14: ...isconnect brine tube and drain line connections at the injector body 5 Remove the two injector body mounting screws The injector and brine module can now be removed from the control valve Clean and re...

Page 15: ...and brine valve assembly J Salt bridge has formed J Refer to Breaking a Salt Bridge section in manual K No water in brine tank K Ensure safety float is not stuck L Unit is plumbed backwards L Check t...

Page 16: ...ed B Clean or replace injectors C Improper programming C Check programming and reset as needed D Line pressure is too low D Increase line pressure line pressure must be at least 20psi at all times 10...

Page 17: ...13312 Spring Idler 9 1 13164 Drive Gear 10 1 13299 Curved Washer 11 1 13170 Main Gear Shaft 12 1 1 D09 24 Hour Gear 13 1 13802 Cycle Actuator Gear 14 1 14177 Knob Manual Regeneration 15 2 13300 Ball...

Page 18: ...eI Beige 1 14207 Knob LabeI Silver control valve assembly time clock control valve body assembly ITEM NO 1 2 3 4 NO REQ D 2 5 1 1 1 1 PART NO 13255 13242 14449 14450 13304 10244 DESCRIPTION Adapter Cl...

Page 19: ......

Page 20: ...Fleet Farm Water Softeners Manufactured By Water Right Inc 1900 Prospect Ct Appleton WI 54914 800 777 1426 Ph 920 739 9406 Fax mail water right com...

Reviews: