OPERATING DISPLAYS AND MAINTENANCE

1 .  GENERAL OPERATION:

 When the system is operating, one of five displays may be shown and will alternate with the installing dealer’s name 

and phone number for future service. Pressing 

NEXT

 will alternate between the displays. 

1.

 

Time of Day Screen:

 Displays the current time of day, the day of the week, and flow rate. 

2. Flow Rate Screen:

 Displays the current treated water flow rate through the system in Gallons Per Minute. 

3. Capacity Remaining Screen:

 Displays the amount of gallons of treated water remaining until the system triggers a regeneration. 

4. Days to a Regen Screen:

 Displays the number of days until the system triggers a regeneration. Based on the days override value. 

5. Dealer Name Screen:

 Displays dealer specific name and phone number. This scrolling display will only appear if set by the dealer. 

If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN TODAY” will appear on the display.
If a water meter is installed, “GPM” flashes on the display when water is being treated, indicating gallons per minute flowing through the system.

2 .  REGENERATION  MODE:

 

Typically, a system is set to regenerate at a time of no water usage. 

If there is a demand for water when the system is regenerating, untreated water will be delivered. 

When the system begins to regenerate, the display will include information about the step of the 

regeneration process and the time remaining for that step to be completed. The system runs through 

the steps automatically and will reset itself to provide treated water when the regeneration has been 

completed.

3 .  MANUAL REGENERATION:

 Sometimes there may be a need to regenerate a unit before the control 

valve calls for it. This may be needed if a period of heavy water use is anticipated or when the system has been 

operating without salt.

 

•  To initiate a manual regeneration at the next preset regeneration time, press and release the 

REGEN 

button. The words “REGEN TODAY” will flash on the display to indicate that the system will regenerate 

at the scheduled regeneration time (see the Programming Procedures section). If you pressed the 

REGEN

 button in error, pressing and releasing the button again will cancel the command.

 

•  To initiate a manual regeneration immediately, press and hold the 

REGEN

 button for three seconds. The system will begin to regenerate 

immediately. 

This command cannot be canceled.

 Once a manual regeneration is initiated, the unit will enter the FILL position. This position allows water to enter the brine tank until it reaches the 

proper level. Once this position is complete, you will notice a 240 minute (4 hours) SOFTENING position. This 4 hour window allows the salt to 

dissolve and achieve proper brine strength. During these FILL and SOFTENING positions, you will have softened water available for use. Once the 

unit advances to the BACKWASH position and subsequent positions thereafter (see Start Up Instructions for regeneration sequence), the unit will 

deliver water, but it will be untreated. 

IMPORTANT: With the Dry Salt Storage Feature, the brine tank will refill 4 hours before the actual regeneration occurs. You may 

experience a small amount of noise for a short period of time at 10:00 p.m. (with factory settings) on the night that the 

regeneration is to occur. This noise is only the brine tank filling and at no time during this process will you be without 

treated water. 

1

FLOW RATE

GPM

8.0

CAPACITY REMAINING

2

5

TIME OF DAY

MON

PM

GPM

2:40

8

GAL

GPM

1600

8

GPM

3

8

3

DAYS TO A REGEN

4

555 5555555

DEALER NA

REGENERATION MODE

BACKWASH

8:22

Current Regen 

Cycle Stage

Time Remaining 

in Stage

MANUAL REGEN

REGEN TODAY

MON

GPM

2:40

8

PM

REGEN TODAY

  and 

TIME OF DAY

 

will flash alternately if a regeneration 

is expected tonight.

Summary of Contents for IMP-1044

Page 1: ...stallation Instructions Owner s Manual Impression Plus Series Metered Water Softeners For Certified Models IMP 844 IMP 948 IMP 1044 IMP 1054 IMP 1248 IMP 1354 Certified Cabinet Models IMPC 835 IMPC 10...

Page 2: ...ully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water softener contact your local dealer YOUR WATE...

Page 3: ...Flow rate capacity remaining and days to a regeneration are optional displays For more explanation consult the operating displays and maintenance section Pressing the NEXT button on a general operatin...

Page 4: ...es point in the direction of flow indicated by the engraved arrows on the control valve Water flows through the control valve for normal operation of a water softener or filter During the regeneration...

Page 5: ...nds the use of an expansion tank on the outlet side of the unit see diagram 5 Do not locate unit where it or its connections including the drain and overflow lines will ever be subjected to temperatur...

Page 6: ...th appropriate air gap see drawing Run drain tube to its discharge point in accordance with plumbing codes Pay special attention to codes for air gaps and anti siphon devices CAUTION Never insert a dr...

Page 7: ...7 This page intentionally left blank...

Page 8: ...gallons Adjustable from 1 to 150 gpg in 1 grain increments default setting is 20 The hardness value is based on the actual compensated hardness of the water and must be set by an authorized dealer fo...

Page 9: ...let handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air CAUTION If water flows too rapidly there will be a loss of media to the drain 3 When the water...

Page 10: ...ater use is anticipated or when the system has been operating without salt To initiate a manual regeneration at the next preset regeneration time press and release the REGEN button The words REGEN TOD...

Page 11: ...cedures and initiate regeneration see operating displays and maintenance If these procedures do not remedy the problem please consult the installing dealer for service 5 ERROR MESSAGE If the word ERRO...

Page 12: ...B Connect meter to three pin connection labeled METER on PC board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into...

Page 13: ...mming Check refill flow control for restrictions or debris and if necessary replace H Damaged seal stack assembly piston H Replace seal stack assembly and or piston I Control valve body type and pisto...

Page 14: ...n the PC board labeled MOTOR Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC bo...

Page 15: ...V NHBP motor to PC board two pin connection labeled DRIVE Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 secon...

Page 16: ...ory screens These do not flash when error occurs A Occurs when dP input is active for ALARM and the input is closed The alarm buzzer will activate and the screen will display the error A Check for low...

Page 17: ...V3540P A Black Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor Assembly 1 3 CV3002 A Drive assembly includes 5 and 6 1 4 CV3579WI 03 PC board Impression 1 CV4229XP 03...

Page 18: ...CV3011 01 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 12 CV3015A WS1 QC2 Tank adapter assembly includes O rings 1 13 CV3001 04 1 body assembly dow...

Page 19: ...1 CV3195 01 Refill port plug assembly 1 2 CH4615 Elbow locking clip 1 3 CV4144 3 8 Elbow Parkerfitting 1 4 CV3163 O ring 019 1 Although no tools are necessary to assemble or disassemble the valve the...

Page 20: ...assembly CV3010 1F F injector assembly CV3010 1G G injector assembly CV3010 1H H injector assembly CV3010 1I I injector assembly CV3010 1J J injector assembly CV3010 1K K injector assembly not shown C...

Page 21: ...n 1 Strt No Sil 1 REPLACEMENT PARTS Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elb...

Page 22: ...4 CH1030 29S 4 x 29 slotted brine well 18 x 33 BT 1 CH1030 36S 4 x 36 slotted brine well 18 x 40 24 x 40 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4620...

Page 23: ...y with 474 Brine Assembly 1 Not shown CH4850 34 625 Brine Well with Brine Well 474 Assembly 34 5 8 1 LOW PROFILE CABINET AND BRINE TANK Item No Part No Description Qty 1 CJ2TCWSLP C Top Assembly Black...

Page 24: ...t No Description Qty CV3007 07 1 1 4 1 1 2 PVC solvent assembly 2 4 CV3352 Fitting 2 3 4 BRASS SHARK BITE Item Part No Description Qty CV3007 12 3 4 brass shark bite assembly 2 4 CV3628 Fitting 2 1 PL...

Page 25: ...ins Lbs Salt N A 4 040 1 Max Service Flow Rate GPM 9 6 16 0 Max Pressure Loss at Max Service PSI 9 0 15 0 Min to Max Working Pressure PSI 30 100 30 100 Min to Max Operating Temperature F 33 100 33 100...

Page 26: ...art or component at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equiva...

Page 27: ...power outage 1 Accessed by pressing 2 Adjust hours with or buttons AM PM toggles at 12 3 Press 4 Adjust minutes with or buttons 5 Press 6 Adjust current day with or buttons 7 Press to complete and ret...

Page 28: ...2021 Water Right Inc All rights reserved MAN IMP CERT RevA0821 1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406...

Reviews: