8
PROGRAMMING PROCEDURES
1
DAYS BETWEEN REGEN
SET
12
3
WATER HARDNESS
SET
20
2
REGEN TIME HOUR
AM
GR
SET
2:00
4
REGEN TIME MINUTES
AM
SET
2:00
5
Return to general display.
LIGHT NORMALLY
SET
ON
6
Optional
Display
Typically, time of day should only need to be set after extended power outages or when daylight saving time begins or ends or after the battery has
been replaced. If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset. To set the clock:
STEP 1 –
Press the
CLOCK
button.
STEP 2 –
Set the hour of the day using
+
or
–
buttons. AM/PM toggles after 12. Press
NEXT
to go to step 3.
STEP 3 –
Set the minutes using
+
or
–
buttons. Press
NEXT
to go to step 4 or
REGEN
to return to previous step.
STEP 4 –
Set the day of the week using
+
or
–
buttons. Press
NEXT
to exit clock setting or
REGEN
to return to previous step.
1
TIME
HOUR
AM
SET
2:00
TIME
MINUTES
AM
SET
2:00
2
3
CURRENT DAY
SET
MON
4
return to general display
TIME OF DAY
MON
PM
GPM
2:40
8
1 . Set Time of Day
The manufacturer has preset the unit so that the gallons between regenerations will be automatically calculated
after the hardness is entered. Press
NEXT
to cycle to the next step or
REGEN
to return to the previous step.
STEP 1
– Press and hold the
NEXT
and
+
buttons simultaneously for 3 seconds.
STEP 2
–
HARDNESS:
Use the
+
or
–
buttons to adjust the hardness value in grains per gallons. Adjustable
from 1 to 150 gpg in 1 grain increments (default setting is 20).
The hardness value is based on the actual compensated hardness of the water and must be set by
an authorized dealer following an on-site water analysis. Adjusting the number will only impact the
frequency of regeneration and will not alter or affect the hardness of the water treated by the unit.
Note: If a resin media is used, increase the grains per gallon if soluble iron is present
(1 ppm = 4 gpg). This screen will not display if “FILTER” mode is selected.
STEP 3
–
DAYS BETWEEN REGENERATION (DAY OVERRIDE):
Use the
+
or
–
buttons to adjust the day
override. Adjustable from 1-28 days or OFF. The manufacturer has factory set 12 days as the default.
The Day Override value represents the maximum number of days between regenerations. If any number
is set (1-28 days), a regeneration will be scheduled for that day if the gallon capacity has not been met. If
OFF is set, the unit will only initiate a regeneration once the gallon capacity has been met.
STEP 4
–
REGENERATION HOUR:
Use the
+
or
–
buttons to adjust the time of day the unit will regenerate.
AM/PM toggles after 12. The manufacturer has factory set 2:00 A.M. as the default setting which is
recommended for a normal household.
STEP 5
–
REGENERATION MINUTES:
Use the
+
or
–
buttons to set minutes.
STEP 6
–
BACKLIGHT DISPLAY CONTROL:
Use the
+
or
–
buttons to turn the backlight setting ON or OFF. If unit
is set to OFF, the backlight will turn off after 5 minutes of inactivity.
This setting is not available on all
models.
Press
NEXT
to return to General Display.
2 . Programming