10
11
OPERATING DISPLAYS AND MAINTENANCE
1 .
GENERAL OPERATION:
When the system is operating, one of five displays may be shown and will alternate with the
installing dealer’s name and phone number (if set) for future service . Pressing
NEXT
will alternate between the displays .
1 .
CURRENT TIME OF DAY
and
GPM.
Letter indicates which tank is in service . GPM alternates with current flow rate .
2 .
FLOW RATE
which is the current treated water flow rate through either tank A or B in Gallons Per Minute .
3. CAPACITY REMAINING
for the tank in service (A or B) and the gallons that will be treated before the system
signals a regeneration cycle and switches to the other tank . GPM alternates with current flow rate .
4 .
DAYS TO A REGEN
is the number of days left before the system goes through a regeneration cycle, based on the
days override value . Letter indicates which tank is in service . GPM alternates with current flow rate .
5 .
DEALER NAME AND PHONE NUMBER (only available on certain models)
is the dealer information to call when
service is needed (this screen will only appear if set by dealer) .
The user can scroll between the displays as desired .
3 .
REGENERATION MODE:
Typically a twin system regenerates when the capacity
of the tank providing treated water reaches zero remaining gallons . At this time, the
online tank will transfer and put the standby tank online so there is no disruption of
treated water . Once this transfer is complete, the depleted tank will regenerate and
return to standby mode ready to enter service upon depletion of capacity of other
tank . This two tank configuration provides for a continuous, uninterrupted supply of
conditioned water at all times . When the system begins to regenerate, the display
will change to include information about the step of the regeneration process and
the time remaining for that step to be completed . The system will run through all
remaining steps automatically and will reset to provide treated water when the
regeneration process has been completed .
2 .
MANUAL REGENERATION:
Sometimes there is a need to regenerate before the
control valve calls for it . This may be needed if the system has been operated without
salt for an extended period of time . To initiate a manual regeneration
immediately,
press and hold the
REGEN
button for three seconds . The system will begin to
regenerate immediately .
This command cannot be cancelled.
Once a manual regeneration is initiated, the unit will transfer to the second tank in
order to supply conditioned water . Upon transfer, the depleted tank will begin its
regeneration .
BACKWASH
8:22
REGENERATION MODE
TIME OF DAY
MON
GPM
2:40
A
PM
1
FLOW RATE
GPM
8.0
A
CAPACITY REMAINING
GPM
GAL
1600
A
DAYS TO A REGEN
GPM
3
A
555 5555555
DEALER NA
4
2
5
3
REGEN TODAY
MON
GPM
2:40
8
PM
REGEN TODAY
and
TIME OF DAY
will flash alternately if a regeneration
is expected tonight.
MANUAL REGENERATION