32

SANITIZER

®

 PLUS TWIN SPECIFICATIONS

  *All specs are shown in capacity per tank. 
  

NOTE:

 Only the -844TW through the -1354TW sizes are approved in the state of Wisconsin.

1

  All Sanitizer Plus Twin water conditioners are pre-factory set at medium salting. 

 

NOTE:

 Influent waters must be at least 3 GPG hardness and 80 TDS. A calcite or corsex unite may be needed for  

 

           correct operation.

2

   Combined iron and managnese removal varies depending on the form of iron, manganese, pH and other local conditions. On waters 

that are pre-chlorinated or where other pre-oxidation occurs, precipitated metal oxides may form that are too fine to be filtered.

3

  The pH listed is the minimum for influent water.

4

  Optimum pH adjustment occurs at 3.0 gpm or less at maximum salt settings. Higher flow rates will produce less pH adjusted water.

5

  Unit not tested for capacity at these flow rates. Water quality may vary.

Twin Series Conditioners

Specifications

Manufactured by Water-Right, Inc.  •  1900 Prospect Court  •  Appleton, WI 54914  •  800-777-1426  •  water-right.com                   

    

 

SPE-SAN PL TWIN      RevA0318

CYCLE TIMES AND USAGE

ASP1 SPECIFICATIONS

ASP2 SPECIFICATIONS

MODEL

ASP1-1044TW

ASP1-1054TW

ASP1-1354TW

ASP1-1465TW

ASP1-1665TW

1

Capacity:*

(Grains/Lbs. NaCl)

Minimum

7,300 @ 3.2

16,400 @ 6.1

28,300 @ 9.5

40,000 @ 13.0

51,000@ 17.0

Medium

11,400 @ 9.3

20,700 @ 12.4

33,600 @ 15.9

47,000 @ 22.0

60,000 @ 29.0  

Maximum

11,800 @ 12.4

22,600 @ 15.9

36,900 @ 21.2

52,000 @ 30.0

51,000 @ 17.0

Amount of Media (Cu.Ft.)

1.0

1.5

2.5

3.5

4.5

Maximum Water Hardness (GPG)

20

30

40

40

40

2

Maximum Iron and Manganese (PPM)

8.0

10.0

15.0

15.0

15.0

3

Minimum pH

6.5

6.0

6.0

6.0

6.0

4

Total pH Adjusted Water 

510

510

863

N/A

N/A

5

Peak Flow Rate (GPM @ P-PSI)

19.0 @ 8.3

17.0 @ 7.8

19.0 @ 7.6

26.0 @ 25.0

26.0 @ 25.0

Continuous Flow Rate (GPM @ P-PSI)

9.0 @ 2.4

9.0 @ 2.8

9.0 @ 2.7

19.0 @ 15.0

19.0 @ 15.0

Water Pressure Range (PSI)

25-100

25-100

25-100

25-100

25-100

Water Temp. (ºF)

33-100

33-100

33-100

33-100

33-100

Electrical Requirements (volts-hertz)

110-50/60

110-50/60

110-50/60

110-50/60

110-50/60

Pipe Size

1”

1”

1”

1”

1”

Total Dimensions:

Media Tank 

10”W x 52”H

10”W x 62”H

13”W x 62”H

14”W x 65”H

16”W x 65”H

Brine Tank

18”W x 33”H

18”W x 33”H

18”W x 40”H

18”W x 40”H

24”W x 41”H

MODEL

ASP2-1044TW

ASP2-1054TW

ASP2-1354TW

ASP2-1465TW

ASP2-1665TW

1

Capacity:*

(Grains/Lbs. NaCl)

Minimum

11,100 @ 3.2

22,900 @ 6.1

28,200 @ 9.3

40,000 @ 13.0

52,000 @ 17.0

Medium

19,100 @ 9.3

32,000 @ 12.4

48,300 @ 15.9

68,000 @ 22.0

87,000 @ 29.0  

Maximum

20,300 @ 12.4

34,800 @ 15.9

60,300 @ 26.5

84,000 @ 37.0

108,000 @ 48.0

Amount of Media (Cu.Ft.)

1.0

1.5

2.5

3.5

4.5

Maximum Water Hardness (GPG)

40

60

80

80

80

2

Maximum Iron and Manganese (PPM)

8.0

10.0

15.0

15.0

15.0

3

Minimum pH

7.0

7.0

7.0

7.0

7.0

4

Total pH Adjusted Water 

N/A

N/A

N/A

N/A

N/A

5

Peak Flow Rate (GPM @ P-PSI)

19.0 @ 9.3

17.0 @ 9.1

19.0 @ 8.6

26.0 @ 25.0

26.0 @ 25.0

Continuous Flow Rate (GPM @ P-PSI)

9.0 @ 3.0

8.0 @ 3.7

9.0 @ 2.8

19.0 @ 15.0

19.0 @ 15.0

Water Pressure Range (PSI)

25-100

25-100

25-100

25-100

25-100

Water Temp. (ºF)

33-100

33-100

33-100

33-100

33-100

Electrical Requirements (volts-hertz)

110-50/60

110-50/60

110-50/60

110-50/60

110-50/60

Pipe Size

1”

1”

1”

1”

1”

Total Dimensions:

Media Tank 

10”W x 52”H

10”W x 62”H

13”W x 62”H

14”W x 65”H

16”W x 65”H

Brine Tank

18”W x 33”H

18”W x 33”H

18”W x 40”H

18”W x 40”H

24”W x 41”H

MODEL

ASP1-1044

ASP2-1044

ASP1-1054

ASP2-1054

ASP1-1354

ASP2-1354

ASP1-1465

ASP2-1465

ASP1-1665

ASP2-1665

MIN.

GAL.

MIN.

GAL.

MIN.

GAL.

MIN.

GAL.

MIN.

GAL.

Brine Refill

5:51

3

9:53

5

11:53

6

23:00

11.5

30:00

15

Backwash 

12

42

12

48

12

90

12

36

12

108

Brine & Rinse

72

29

90

36

90

50

90

72

90

90

Rapid Rinse

4

14

4

16

4

30

4

30

4

36

Total

94

88

116

105

118

176

129

203.5

136

249

Summary of Contents for Impression Plus IMP-1044TW

Page 1: ...Twin Water Softeners For Models IMP 844TW ASP1 1044TW IMP 1044TW ASP1 1054TW IMP 1054TW ASP1 1354TW IMP 1354TW ASP1 1465TW IMP 1465TW ASP1 1665TW IMP 1665TW IMPRC 1054TW ASP2 1044TW IMPRC 1354TW ASP2...

Page 2: ...rated properly Please study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water...

Page 3: ...dels Read Normal Operating Displays Set Time of Day Read Power Loss Error Display Be sure system and installation are in compliance with all state and local laws and regulations For the homeowner plea...

Page 4: ...r flows through the control valve for normal operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated...

Page 5: ...a firm level surface 1 The distance between the drain and the water conditioner should be as short as possible see step 8 2 Since salt must be periodically added to the brine tank it should be locate...

Page 6: ...s could cause interior damage to the flow control Install a 1 2 I D flexible plastic tube to the Drain Line Assembly or discard the tubing nut and use the 3 4 NPT fitting for rigid pipe recommended If...

Page 7: ...tion however an overflow line connection will direct the overflow to the drain instead of spilling on the floor where it could cause considerable damage This fitting is an elbow on the side of the bri...

Page 8: ...ation initiation will be called for on that day even if a sufficient number of gallons were not used to call for a regeneration By default this regeneration will occur at 2 00 a m Set Day Override usi...

Page 9: ...ed time after a regeneration if there is no salt or if another error has occurred Turn the alarm OFF or ON using the or buttons Press NEXT NOTE This feature allows you to program the time in which the...

Page 10: ...ess the REGEN button to advance the control to the BRINE position 4 With the bypass now in diagnostic mode Fig 3 on page 4 check to verify that water is being drawn from regenerant tank with no air le...

Page 11: ...dby tank online so there is no disruption of treated water Once this transfer is complete the depleted tank will regenerate and return to standby mode ready to enter service upon depletion of capacity...

Page 12: ...ally indicates that the salt level in the brine tank is too low to operate properly If CHECK SALT appears there will usually be an audible alarm that sounds also if turned on alerting you to these con...

Page 13: ...Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed secure...

Page 14: ...G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body type a...

Page 15: ...ston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NE...

Page 16: ...seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not conne...

Page 17: ...uzzer will activate and the screen will display the error A Check for low flow leak Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply...

Page 18: ...ews on each side that retain the transfer drive cap assemblies on both sides of the valve 8 Once the screws are removed from retaining the inlet side transfer valve cap and the outlet drive motor tran...

Page 19: ...re to be certain the meter cable doesn t get under the drive cap while tightening as it will result in damaging the cable 17 Position the large white drive gear with the A pointing toward the one o cl...

Page 20: ...cover 1 2 CV3107 1 Motor 1 3 CV3002A Drive bracket spring clip Includes 5 6 1 4 CV3554WS PC board for Sanitizer Plus 1 CV3813WP PC board for Impression Plus 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Dr...

Page 21: ...embly 1 3 CV3135 O ring 228 1 4 CV3011 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 5 CV3174 Regenerant piston 1 6 CV3541 Drive backplate 1 REPLACEMENT PARTS IN OUT HEAD FOR TANK...

Page 22: ...22 REPLACEMENT PARTS...

Page 23: ...1 18 CV3264 WS2H bypass reduction gear axle 3 19 CV3110 WS1 drive reducing gear 12 x 36 3 20 CV3262 01 WS1 5 2 ALT 2BY reduction gear cover assembly 1 21 CV3592 Screw 8 1 PHPN T 25 SS 3 22 CV4049 T1 c...

Page 24: ...1 CV3195 01 Refill port plug assembly 1 2 CH4615 Elbow locking clip 1 3 CV4144 3 8 Elbow Parker fitting 1 4 CV3163 O ring 019 1 Although no tools are necessary to assemble or disassemble the valve th...

Page 25: ...embly BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GR...

Page 26: ...n 1 Strt No Sil 1 REPLACEMENT PARTS Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elb...

Page 27: ...1030 36S 4 x 36 slotted brine well 18 x 40 24 x 41 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4620 474 float assembly 7 1 8 CH4600 50 474 safety brine val...

Page 28: ...TANKS Item No Part No Description Qty CV4052 01 Interconnect kit for tanks 12 and larger 1 1 CV3151 Nut 1 QC 4 2 CV3150 Split ring 4 3 CV3105 O ring 215 4 4 CV3352 1 1 4 1 1 2 PVC solvent fitting 4 5...

Page 29: ...CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2...

Page 30: ...2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105...

Page 31: ...31 This page left intentionally blank...

Page 32: ...26 0 25 0 26 0 25 0 Continuous Flow Rate GPM P PSI 9 0 2 4 9 0 2 8 9 0 2 7 19 0 15 0 19 0 15 0 Water Pressure Range PSI 25 100 25 100 25 100 25 100 25 100 Water Temp F 33 100 33 100 33 100 33 100 33...

Page 33: ...100 30 100 30 100 30 100 30 100 30 100 Water Temperature F 33 100 33 100 33 100 33 100 33 100 33 100 Electrical Requirements volts hertz 110 50 60 110 50 60 110 50 60 110 50 60 110 50 60 110 50 60 Pi...

Page 34: ...r replace the part or component at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes a...

Page 35: ...ess NEXT 4 Adjust minutes with and buttons 5 Press NEXT 6 Adjust current day with and buttons 7 Press NEXT to complete and return to normal operation DAYS TO A REGEN GPM 3 A FLOW RATE GPM 8 0 TIME OF...

Page 36: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 2018 Water Right All rights reserved MAN WR TWIN RevA0818...

Reviews: