8
9
STEP 4
–
IMMEDIATE REGENERATION:
The manufacturer has set the
regeneration to occur when zero gallons remain . When this occurs,
the standby tank will switch into service and provide treated water
while the tank requiring regeneration will start this process .
STEP 5
–
SERVICE ALARM GALLONS
(optional setting only available on
Conditioner models)
:
The manufacturer has factory set “OFF” as the
default . This feature is used to signal service into the future . This is
typically set by the installing dealer to warn homeowner that service is
required after a preset number of gallons have been consumed . If the
feature is active, a specific gallon amount will appear .
STEP 6
–
SERVICE ALARM TIME
(optional setting only available on Conditioner
models)
:
The manufacturer has factory set “OFF” as the default . This
feature is used to signal service into the future . This is typically set by
the installing dealer to warn homeowner that service is required after a
period of time has passed . If the feature is active, a specific number of
days will appear .
STEP 7
–
ALARM BUZZER
(optional setting only available on Conditioner
models)
:
The manufacturer has factory set “ON” as the default . An alarm
will sound (at the indicated time) after a regeneration, if there is no salt
or if another error has occurred . Turn the alarm “OFF” or “ON” using
the
+
or
—
buttons . Press
NEXT
.
NOTE:
This feature allows you to program the time in which the alarm
buzzer will sound, permitting the installer to pick a time when the owner
will be home or awake to hear it .
Setting Alarm Buzzer Start Time:
Press
+
or
—
button to select the
correct hour the buzzer is to start sounding . Be sure to also set AM or PM
as necessary . (Default is set to 6:00 a .m .) Press
NEXT
.
Setting Alarm Buzzer End Time:
Press
+
or
—
button to select the
correct hour the buzzer is to stop sounding in the day . Be sure to also
set AM or PM as necessary . (Default is set to 10:00 p .m .) Press
NEXT
.
STEP 8
–
DISPLAY BACKLIGHT
:
The manufacturer has factory set “ON” by
default . Turn the light “OFF” or “ON” using the
+
or
—
buttons .
“OFF” will turn display backlight off after five minutes of keypad
inactivity . Press
NEXT
to exit installer programming .
REGEN IMMEDIATE
ON ZERO
GAL
4
5
SERVICE ALARM GAL
SET
100
GAL
SERVICE ALARM
SET
OFF
GAL
ALARM BUZZER START
SET
ALARM BUZZER END
SET
6:00
AM
10:00
PM
ALARM BUZZER
SET
ON
7
LIGHT NORMALLY
SET
ON
8
6
SERVICE ALARM TIME
SET
1.25
YR
SERVICE ALARM
SET
OFF
YR
PROGRAMMING PROCEDURES
NOTE:
STEPS 5-7 ARE ONLY AVAILABLE ON CONDITIONER UNITS.
NOTE:
To alternate between tanks without activating a regeneration, press and
hold CLOCK and + simultaneously for three seconds.
Summary of Contents for Impression Plus IMP-1044TW
Page 22: ...22 REPLACEMENT PARTS...