8
PROGRAMMING PROCEDURES
1. Set time of day:
2. Programming:
Time of day should only need to be set after extended power outages or when daylight saving time begins or ends . If an
extended power outage occurs, the time of day will flash on and off indicating that the time should be reset .
STEP 1
– Press
CLOCK
.
STEP 2
–
CURRENT TIME (HOUR):
Set the hour of the day using
+
or
—
buttons . AM/PM toggles after 12 . Press
NEXT
to go to step 3 .
STEP 3
–
CURRENT TIME (MINUTES):
Set the minutes using
+
or
—
buttons . If it is desired to back up to the previous
step press
REGEN
button once .
STEP 4
–
CURRENT DAY:
Set the day of the week using
+
or
—
buttons . Pressing
NEXT
will exit
SET
CLOCK
and return to
the general operating display .
1
TIME
HOUR
AM
SET
2:00
TIME
MINUTES
AM
SET
2:00
2
3
CURRENT DAY
SET
MON
4
Return to general display.
NOTE:
The manufacturer has preset the unit so that the gallons between regenerations will be
automatically calculated after the hardness is entered . Press
NEXT
to cycle to the next step or
REGEN
to return to the previous step .
STEP 1
– Press
NEXT
and
+
simultaneously for 3 seconds .
STEP 2
–
HARDNESS:
Set the amount of hardness in grains per gallon (default 20) using the
+
or
—
buttons . The allowable range is from 1 to 150 in 1 grain increments .
NOTE:
If a resin media is used in the softener, increase the grains per gallon if
soluble iron is present (1 ppm = 4 gpg) . This display will show “GALLONS AVAILABLE
BETWEEN REGENERATIONS” if “FILTER” is selected .
STEP 3
–
DAY OVERRIDE:
The manufacturer has factory set 12 DAYS as the default . This
is the maximum number of days between regenerations . If this is set to “OFF”,
regeneration initiation is based solely on gallons used . If any number is set (allowable
range from 1 to 28), a regeneration initiation will be called for on that day even if a
sufficient number of gallons were not used to call for a regeneration .
Set Day Override using
+
or
—
buttons (12 is recommended):
• set number of days between regeneration (1 to 28); or
• set to “OFF” .
STEP 4
–
REGENERATION HOUR:
The manufacturer has factory set 2:00 A .M . as the default .
This is the hour of day for regeneration and can be reset by using
+
or
—
buttons .
“AM/PM” toggles after 12 . The default time is 2:00 a .m . (recommended for a normal
household) .
STEP 5
–
REGENERATION MINUTES:
Set the minutes using
+
or
—
buttons .
STEP 6
–
BACKLIGHT DISPLAY CONTROL
(Not available on all models)
:
Set the display
backlight on or off using
+
or
—
buttons . In the OFF position, the backlight will turn
off after 5 minutes of inactivity .
1
DAYS BETWEEN REGEN
SET
12
3
WATER HARDNESS
SET
20
2
REGEN TIME HOUR
AM
GR
SET
2:00
4
REGEN TIME MINUTES
AM
SET
2:00
5
Return to general display.
LIGHT NORMALLY
SET
ON
6
Optional
Display