PROGRAMMING PROCEDURES

1. Set time of day:

2. Programming:

Time of day should only need to be set after extended power outages or when daylight saving time begins or ends . If an 

extended power outage occurs, the time of day will flash on and off indicating that the time should be reset .

STEP 1

 – Press 

CLOCK

 .

STEP 2

 –  

CURRENT TIME (HOUR): 

Set the hour of the day using 

+

 or 

 buttons . AM/PM toggles after 12 . Press 

NEXT

 

to go to step 3 .

STEP 3

 –  

CURRENT TIME (MINUTES):

 Set the minutes using 

+

 or 

 buttons . If it is desired to back up to the previous 

step press 

REGEN

 button once .

STEP 4

 –  

CURRENT DAY:

 Set the day of the week using 

+

 or 

 buttons . Pressing 

NEXT

 will exit 

SET

 

CLOCK

 and return to 

the general operating display .

1

TIME

HOUR

AM

SET

2:00

TIME

MINUTES

AM

SET

2:00

2

3

CURRENT DAY

SET

MON

4

Return to general display.

NOTE:

 The manufacturer has preset the unit so that the gallons between regenerations will be 

automatically calculated after the hardness is entered .  Press 

NEXT

 to cycle to the next step or 

REGEN

 to return to the previous step . 

STEP 1

 – Press 

NEXT

 and 

+

 simultaneously for 3 seconds .

STEP 2

 –  

HARDNESS: 

Set the amount of hardness in grains per gallon (default 20) using the 

+

 

or 

 buttons . The allowable range is from 1 to 150 in 1 grain increments .

 

   

NOTE: 

If a resin media is used in the softener, increase the grains per gallon if 

 

   soluble iron is present (1 ppm = 4 gpg) . This display will show “GALLONS AVAILABLE  

 

   BETWEEN REGENERATIONS” if “FILTER” is selected . 

STEP 3

 –  

DAY OVERRIDE: 

The manufacturer has factory set 12 DAYS as the default . This 

is the maximum number of days between regenerations . If this is set to “OFF”, 

regeneration initiation is based solely on gallons used . If any number is set (allowable 

range from 1 to 28), a regeneration initiation will be called for on that day even if a 

sufficient number of gallons were not used to call for a regeneration .

 

  Set Day Override using 

+

 or 

 buttons (12 is recommended):

 

 

• set number of days between regeneration (1 to 28); or

 

 

• set to “OFF” .

STEP 4

 –  

REGENERATION HOUR: 

The manufacturer has factory set 2:00 A .M . as the default . 

This is the hour of day for regeneration and can be reset by using 

+

 or 

 buttons . 

“AM/PM” toggles after 12 . The default time is 2:00 a .m . (recommended for a normal 

household) .

STEP 5

 – 

 REGENERATION MINUTES: 

Set the minutes using 

+

 or 

 buttons .

STEP 6

 – 

 BACKLIGHT DISPLAY CONTROL 

(Not available on all models)

: 

Set the display 

backlight on or off using 

+

 or 

 buttons . In the OFF position, the backlight will turn 

off after 5 minutes of inactivity .

1

DAYS BETWEEN REGEN

SET

12

3

WATER HARDNESS

SET

20

2

REGEN TIME HOUR

AM

GR

SET

2:00

4

REGEN TIME MINUTES

AM

SET

2:00

5

Return to general display.

LIGHT NORMALLY

SET

ON

6

Optional 

Display

Summary of Contents for Impression RC Series

Page 1: ...ion RC Series Metered Water Softeners For Models IM 844 IMP 844 IM 948 IMP 948 IM 1044 IMP 1044 IM 1054 IMP 1054 IM 1248 IMP 1248 IM 1354 IMP 1354 IMC 835 IMPC 835 IMC 1035 IMPC 1035 IMRC 1054 IMPRC 1...

Page 2: ...efore installing This manual should be kept for future reference If you have any questions regarding your water softener contact your local dealer or Water Right at the following Water Right Inc 1900...

Page 3: ...Remaining and Days to a Regeneration are optional displays but are not normally used Each of these can be viewed by pressing NEXT to scroll through them When stepping through any programming if no but...

Page 4: ...r flows through the control valve for normal operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated...

Page 5: ...nd the water conditioner should be as short as possible see step 8 2 Since salt must be added periodically to the brine tank it should be in an easily accessible location 3 It is NOT recommended to in...

Page 6: ...this could cause interior damage to the flow control Install a 1 2 I D flexible plastic tube to the Drain Line Assembly or discard the tubing nut and use the 3 4 NPT fitting for rigid pipe recommende...

Page 7: ...tion however an overflow line connection will direct the overflow to the drain instead of spilling on the floor where it could cause considerable damage This fitting is an elbow on the side of the bri...

Page 8: ...increments NOTE If a resin media is used in the softener increase the grains per gallon if soluble iron is present 1 ppm 4 gpg This display will show GALLONS AVAILABLE BETWEEN REGENERATIONS if FILTER...

Page 9: ...the inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air CAUTION If water flows too rapidly media will be lost to the drain 3 When the water is f...

Page 10: ...ed or when the system has been operated without salt To initiate a manual regeneration at the next preset regeneration time press and release REGEN The words REGEN TODAY will flash on the display to i...

Page 11: ...l valve was not able to function properly 6 BRINE TANK MAINTENANCE AND SALT Refill the brine tank as necessary making sure at least 1 3 of the brine tank is full at all times Without proper salt level...

Page 12: ...Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed secure...

Page 13: ...G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body type a...

Page 14: ...ston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NE...

Page 15: ...seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not conne...

Page 16: ...uzzer will activate and the screen will display the error A Check for low flow leak Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply...

Page 17: ...17 This page left intentionally blank...

Page 18: ...lack Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor 1 3 CV3002A Drive bracket spring clip Includes 5 6 1 4 CV3579WI PC board Impression 1 CV3813WP PC board Impressio...

Page 19: ...nerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 00318337 Nut 1 4 20 HEX 18 8SS 1 10 CV3016 QC2 clamp assembly includes screw nut 1 11 CV3452 O ri...

Page 20: ...PARTS 2 4 1 3 BRINE ELBOW ASSEMBLY Item No Part No Description Qty 1 CV3195 01 Refill port plug assembly 1 2 CH4615 Elbow locking clip 1 3 CV4144 3 8 Elbow Parker fitting 1 4 CV3163 O ring 019 1 Altho...

Page 21: ...embly BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GR...

Page 22: ...n 1 Strt No Sil 1 REPLACEMENT PARTS Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elb...

Page 23: ...1030 36S 4 x 36 slotted brine well 18 x 40 24 x 40 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4620 474 float assembly 7 1 8 CH4600 50 474 safety brine val...

Page 24: ...AND BRINE TANK Item No Part No Description Qty 1 CJ2TCWS HEH Top Assembly Light Gray Dark Gray 1 2 CJ2B35E Bottom Assembly Light Gray with 474 Brine Assembly 1 Not shown CH4850 34 625 Brine Well with...

Page 25: ...25 This page left intentionally blank...

Page 26: ...CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2...

Page 27: ...2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105...

Page 28: ...ure Range PSI 25 100 25 100 25 100 25 100 25 100 25 100 Water Temp F 33 100 33 100 33 100 33 100 33 100 33 100 Electrical Requirements volts hertz 110 50 60 110 50 60 110 50 60 110 50 60 110 50 60 110...

Page 29: ...replace the part or component at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes an...

Page 30: ...stored in memory no matter how long the power outage 1 Accessed by pressing SET CLOCK 2 Adjust hours with and buttons AM PM toggles at 12 3 Press NEXT 4 Adjust minutes with and buttons 5 Press NEXT 6...

Page 31: ...31 This page left intentionally blank...

Page 32: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 2018 Water Right Inc All rights reserved MAN IM IMP SOFT RevA0818...

Reviews: