background image

15

SOFTWARE VERSION

XXX

xx

TOTAL GALLONS

0

X1K

TOTAL DAYS

970

TOTAL REGENS

190

1

ERROR LOG

101

1

4

5

2

3

Second Level History Screens   

 

 

 

 

 

       

Accessed by pressing 

+

 and 

 simultaneously for three seconds. 

Once screen changes, press 

+

 and 

 simultaneously again for three seconds.

Non-resettable history.

Displays software version

Displays total gallons used by 

Meter 1 since startup

Displays total days unit has 

been in service

Displays total regens since startup

Displays last ten valve errors that occurred

Scroll through with 

+

 or 

– 

buttons.

Return to general display

Error Code

Error Code Description

101

UNABLE TO START:

Valve not sensing valve movement with motor energized.

102

MOTOR STALLED:

Valve unable to find next cycle position (stalled).

103

MOTOR RAN TOO LONG:

Valve unable to find next cycle position.

104

VALVE HOMING:

Valve unable to find Home position.

106

MAV 1 RAN TOO LONG:

MAV 1 motor ran too long. Unable to find proper park position.

107

MAV 1 STALLED:

MAV 1 motor ran too short. Unable to find proper park position (stalled).

109

INVALID MOTOR STATE:

Control can no longer operate properly due to detection of an invalid motor state. 

116

MAV 2 RAN TOO LONG:

MAV 2 motor ran too long. Unable to find proper park position. 

117

MAV 2 STALLED:

MAV 2 motor ran too short (stalled). Unable to find proper park position.

201

INVALID REGEN STEP:

Control can no longer operate properly due to detection of an invalid  

regeneration cycle step. Internal software issue.

204

LEAK DETECTED

402

POWER DOWN MEMORY:

Check sum error for operational data and status section of EEPROM memory 

 

- specific type of memory error. 

403

PROGRAM MEMORY:

Check sum error for programming section of EEPROM memory

 

- specific type of memory error.

404

DIAGNOSTIC MEMORY:

Check sum error for diagnostic section of EEPROM memory 

 

- specific type of memory error.

405

HISTORY MEMORY:

Check sum error for history section of EEPROM memory 

 

- specific type of memory error.

406

CONTACT MEMORY:

Check sum error for contact screen section of EEPROM memory 

 

- specific type of memory error.

407

STATUS RAM MEMORY 

 

FAILURE:

Control can no longer operate properly due to corrupted data detected in the Operational Data and Status Section 

of RAM memory. Once generated, the Error Mode is not entered nor an error displayed, instead previously stored 

data (<6 hours old) is used to maintain control operation.

408

DIAGNOSTIC RAM 

 

MEMORY FAILURE:

Control can no longer operate properly due to corrupted data detected in the Operational Data and Status Section 

of RAM memory. Once generated, the Error Mode is not entered nor an error displayed, instead previously stored 

data (<6 hours old) is used to maintain control operation.

410

CONFIG DOWNLOAD:

Configuration file downloaded to the control was not originally uploaded from 

 

another control with the identical software revision.

Error Codes and Descriptions

REMINDER:

 

Press and hold 

NEXT

 and 

REGEN

 for three seconds to perform a soft reset and clear an error on screen.

Summary of Contents for Impression

Page 1: ...For Models Impression Impression Plus Impression Twin Master Programming Guide October 2019 Edition...

Page 2: ...Set hours with or buttons AM PM toggles after 12 AM Displays time remaining in current regeneration cycle 2 flashes for a second backwash if two backwashes are programmed Displays time remaining incur...

Page 3: ...see Service OEM page regen will be immediate once total capacity is exhausted and ON ZERO will be displayed Default setting is 2 00 AM Set backlight operation with or buttons Default setting is ON OFF...

Page 4: ...s the or buttons to program characters Press next to advance to the next character Pressing next twice moves to the next screen 55 characters are allowed Press the or buttons to program characters Pre...

Page 5: ...Pressing the NEXT button will advance the cursor one position to the right Continuing to press the NEXT button will advance to the contact name display Scrolling contact name screen Set contact name b...

Page 6: ...or buttons AUTO automatically calculates gallon capacity OFF will regen by days override setting only GALS BETWEEN REGEN will regen by specific gallon setting Default setting is AUTO Set double regen...

Page 7: ...ve minutes of inactivity Set fourth cycle position with or buttons Set draw time with or buttons Default setting is 90 00 minutes Set fifth cycle position with or buttons Set final rapid rinse time wi...

Page 8: ...r buttons If you have selected SOFTENING please refer to Service OEM SOFTENING screens page 5 6 Set gallons of capacity with or buttons To turn off set below 0 OFF does not use metered water to determ...

Page 9: ...itions can be programmed into a regeneration An END position triggers the end of a regeneration and a return to service Press and hold CLOCK and buttons simultaneously for three seconds to access OZON...

Page 10: ...fault setting is OFF WARNING External contact is needed to operate any of the above settings properly If no external contact is connected no setting is needed Set regen time control with or buttons DE...

Page 11: ...by this press NEXT Set relay setpoint with or buttons This is the delay time period after regen starts that relay will initially energize 0 indicates an immediate start Set relay setpoint with or butt...

Page 12: ...elay will be energized while unit is in an error mode To set by this press NEXT Set relay trigger with or buttons FLOW indicates that relay will close whenever flow is detected by the control To set b...

Page 13: ...enerate Only appears on units set to 1 0T Mode Displays tank transfer history Use or buttons to scroll through last 10 tank transfers Visible in 1 0T Mode only 1 indicates most recent tank transfer A...

Page 14: ...Visible only if SERVICE OEM is set to OZONE ON Displays MAV drive time history for an active MAV 1 output Use or buttons to select a MAV output Pushing both and buttons will reset this display First A...

Page 15: ...e to detection of an invalid regeneration cycle step Internal software issue 204 LEAK DETECTED 402 POWER DOWN MEMORY Check sum error for operational data and status section of EEPROM memory specific t...

Page 16: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 MAN IMP MASTER Rev A1019...