8
DBL REGEN
SET
OFF
CYCLE 1
20
SEC
BACKWASH-AIR
SET
BACKWASH-AIR TIME
SET
GAL
GALLONS CAPACITY
SET
1000
FILTERING
SET
TYPE
CYCLE 2
BACKWASH
SET
CYCLE 3
REGENERANT DRAW DN
SET
10:00
MIN
BACKWASH TIME
SET
1
2
3
4
5
BACKWASH
SET
5
1
MIN
MIN
5
MIN
RINSE
4
MIN
RINSE
SET
BACKWASH
SET
SET
6
7
8
Service/OEM FILTERING Screens
Accessed by pressing and holding
NEXT
and
–
simultaneously for three seconds.
Returns to general display after five minutes of inactivity.
NOTE:
Numbers and cycles used as examples on this page are typical of AIR FILTER systems.
Select SOFTENING or FILTERING with + or — buttons
If you have selected SOFTENING, please refer to
“Service/OEM SOFTENING screens”, page 5-6.
Set gallons of capacity with + or — buttons
To turn off, set below 0. OFF does not use metered water to
determine a regen and will not be an option of days override is
not set. Default setting is 1000 gallons.
Set double regen point with + or — buttons
If unit’s capacity is overrun by this percentage, the unit will
regen two nights in a row. Default setting is OFF.
Set first cycle position with + or — buttons
Set backwash-air position time with + or — buttons
Default setting is 20 seconds.
Set backwash time with + or — buttons
Default setting is 10:00 minutes.
Set second cycle position with + or — buttons
Set third cycle position with + or — buttons
continue to next page
Cycle Sequence for
Backwashing Filters