Service Alarm Settings

Accessed by pressing and holding 

+

 and 

CLOCK

 buttons simultaneously for three seconds on the REGEN TIME HOUR screen. 

Returns to general display after five minutes of inactivity.

 

SERVICE ALARM

SET

OFF

GAL

SERVICE ALARM

SET

OFF

YR

SERVICE ALARM

SET

10000

GAL

10000

GAL

CALL FOR SERVICE

IN

SERVICE ALARM

SET

1.00

YR

364

DAYS

CALL FOR SERVICE

IN

Turn service alarm by gallons ON or OFF with + or — buttons 

Default setting is OFF. 

Turn service alarm by years ON or OFF with + or — buttons

Default setting is OFF. 

Use + or — buttons to set number of gallons

Adjustable from 100 - 9,999,000 gallons in 100 

gallon increments. 

Use + or — buttons to set number of gallons 

Adjustable from .25 - 9.75 years in .25 year increments. 

Status Display

Shows the gallons remaining before the service 

alarm will trigger. Press and hold the 

+

 and 

 

buttons  simultaneously for three seconds to 

reset to the gallon setpoint. 

Status Display

Shows the time remaining before the service alarm will trigger. Press the 

+

 and 

 buttons for three seconds to reset to the year setpoint. 

Continue to step 4 on page 3

 

The service alarm feature is used to warn 

the owner that the unit currently needs 

service. Some application examples includes 

reminding the owner when a filter needs 

replacement, when an R.O. system needs 

servicing, or when routine maintenance 

needs to be performed. This can be set by 

gallons, time, or both. Default is OFF for both. 

NOTE:

When using service alarms, the top line will 

read "Call for Service" and will alternate 

with contact screen when in alarm mode. 

To reset a service alarm while in 

status display, press + and – buttons 

simultaneously for three seconds. This 

will reset both gallon and year alarms 

independently. 

Summary of Contents for Sanitizer Plus

Page 1: ...Master Programming Manual for Sanitizer Plus Models Effective February 2019...

Page 2: ...Set hours with or buttons AM PM toggles after 12 AM Displays time remaining in current regeneration cycle 2 flashes for a second backwash if two backwashes are programmed Displays time remaining incur...

Page 3: ...een See the service alarm section on page 4 to configure alarms Set minutes of regen time with or buttons If IMMEDIATE REGEN is set see Service OEM page regen will be immediate once total capacity is...

Page 4: ...ons remaining before the service alarm will trigger Press and hold the and buttons simultaneously for three seconds to reset to the gallon setpoint Status Display Shows the time remaining before the s...

Page 5: ...capacity OFF will regen by days override setting only GALS BETWEEN REGEN will regen by specific gallon setting The default setting is AUTO Set double regen point with or buttons If unit s capacity is...

Page 6: ...y such as in larger units Consult manufacturer before changing WARNING If resin media is used this setting MUST be set to OFF or LOW Set draw time with or buttons Default setting is 90 00 minutes Set...

Page 7: ...setting is OFF WARNING External contact is needed to operate any of the above settings properly If no external contact is connected no setting is needed Set regen time control with or buttons DELAYED...

Page 8: ...etpoint with or buttons This is the delay time period after regen starts that relay will initially energize 0 indicates an immediate start Set relay setpoint with or buttons This is the gallons that w...

Page 9: ...nit is in an error mode To set by this press NEXT Set relay trigger with or buttons FLOW indicates that relay will close whenever flow is detected by the control To set by this press NEXT Set relay tr...

Page 10: ...hrough each hour of the day selected in the gallon usage history screen To select a different day press the REGEN button to return to the previous screen and select a new day with the or buttons NOTE...

Page 11: ...from tank Displays voltage consumed and brine draw time Errors will be recorded from all brine cycles Displays MAV drive time history for an active MAV 1 output Use or buttons to select a MAV output P...

Page 12: ...e to find proper park position 201 INVALID REGEN STEP Control can no longer operate properly due to detection of an invalid regeneration cycle step Internal software issue 204 LEAK DETECTED 402 POWER...

Page 13: ...13 Notes...

Page 14: ...14 Notes...

Page 15: ...15 Notes...

Page 16: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 MAN SAN PL MAST Rev A0219...

Reviews: