Service Alarm Settings
Accessed by pressing and holding
+
and
CLOCK
buttons simultaneously for three seconds on the REGEN TIME HOUR screen.
Returns to general display after five minutes of inactivity.
SERVICE ALARM
SET
OFF
GAL
SERVICE ALARM
SET
OFF
YR
SERVICE ALARM
SET
10000
GAL
10000
GAL
CALL FOR SERVICE
IN
SERVICE ALARM
SET
1.00
YR
364
DAYS
CALL FOR SERVICE
IN
Turn service alarm by gallons ON or OFF with + or — buttons
Default setting is OFF.
Turn service alarm by years ON or OFF with + or — buttons
Default setting is OFF.
Use + or — buttons to set number of gallons
Adjustable from 100 - 9,999,000 gallons in 100
gallon increments.
Use + or — buttons to set number of gallons
Adjustable from .25 - 9.75 years in .25 year increments.
Status Display
Shows the gallons remaining before the service
alarm will trigger. Press and hold the
+
and
–
buttons simultaneously for three seconds to
reset to the gallon setpoint.
Status Display
Shows the time remaining before the service alarm will trigger. Press the
+
and
–
buttons for three seconds to reset to the year setpoint.
Continue to step 4 on page 3
The service alarm feature is used to warn
the owner that the unit currently needs
service. Some application examples includes
reminding the owner when a filter needs
replacement, when an R.O. system needs
servicing, or when routine maintenance
needs to be performed. This can be set by
gallons, time, or both. Default is OFF for both.
NOTE:
•
When using service alarms, the top line will
read "Call for Service" and will alternate
with contact screen when in alarm mode.
•
To reset a service alarm while in
status display, press + and – buttons
simultaneously for three seconds. This
will reset both gallon and year alarms
independently.
Summary of Contents for Sanitizer Plus
Page 1: ...Master Programming Manual for Sanitizer Plus Models Effective February 2019...
Page 13: ...13 Notes...
Page 14: ...14 Notes...
Page 15: ...15 Notes...