9
cont’d
0:30
MIN
RELAY 1 TRIGGER
SET
REGEN
RELAY 1 TRIGGER
SET
ERROR
RELAY 1 SETPOINT
SET
25
GAL
RELAY 1 DURATION
SET
RELAY 1 SETPOINT
SET
1.00
PPG
RELAY 1 TRIGGER
SET
PULSE
RELAY 1 TRIGGER
SET
FLOW
Configuration Screens
Accessed by pressing and holding
NEXT
and
–
simultaneously for three seconds.
Once screen changes, press and hold
NEXT
and
–
simultaneously again for three seconds.
Set relay trigger with + or — buttons
REGEN GALLONS indicates that relay will be energized after a specified number of gal
-
lons are expended during service and regen. To set by this, press
NEXT
.
Set relay trigger with + or — buttons
ERROR indicates that relay will be energized while unit is in an error mode. To set by
this, press
NEXT
.
Set relay trigger with + or — buttons
FLOW indicates that relay will close whenever flow is detected by the control. To set by
this, press
NEXT
.
Set relay trigger with + or — buttons
PULSE indicates that relay will generate a dry-contact signal output. To set by this,
press
NEXT
.
Set relay setpoint with + or — buttons
This is the gallons that will be expended before relay will
initially energize.
Set relay setpoint with + or — buttons
Set meter pulses per gallon (PPG). Adjustable
from 0.10, 0.25, 0.50, 0.75, and 1.00 – 10.00 in 1
PPG increments.
Set relay duration with + or — buttons
This is the duration of time, after relay setpoint, that relay
will remain energized. Adjustable from 1 sec to 500 min.
return to
general display
return to
general display
return to
general display
continued from
previous page
return to
general display