pH Chart

How to Measure: Place 10-15 mL of test water in a container and 

add 2-3 drops of reagent. Then mix well and check the color of the 

water with the pH chart above.

(The color depends on water quality and reagent.)

The user should be responsible for failure or 

improper selection or improper use of the products 

such as use in any manner for which the product was 

not originally intended. 

This product is subject to changes that enhance its 

performance without prior notification.

If the supply cord is damaged, it must be replaced by the 

manufacturer, its service agent or similarly qualified persons in 

order to avoid a hazard.

This appliance is not intended for use by persons (including 

children) with reduced physical sensory or mental capabilities or 

lack of experience and knowledge, unless they have been given 

supervision or instruction concerning use of the appliance by a 

person responsible for their safety.

Children should be supervised to ensure that they do not 

play with the appliance.

R

Summary of Contents for NMP-9000T

Page 1: ...This product is subject to changes that enhance its performance without prior notification If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unles...

Page 2: ...Specifications Troubleshooting Product Warranty 2 3 4 5 10 12 13 14 16 18 20 22 24 25 26 27 28 29 30 31 o Our Valued Customers able of Contents T ntended Use I We are not responsible for any accidents and or malfunctions due to the improper use of this machine Please keep the manual and warranty card in a safe place so that it s easily accessible when you need it Please refer to this manual often ...

Page 3: ...vy objects Unplug the power cord during general mainte nance repair and inspection and while replacing Do not use power surge protectors with this unit Use unit with its own dedicated power source Regarding the Power Supply This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have b...

Page 4: ...d adjust the position of drain faucet to drain away to the sink Make sure the drain faucet is positioned lower than the unit Do not discharge water over 1 hour In the case where the unit isn t used over a long period of time shut off the valve and unplug the power cord In case of strange noises burning odor or smoke unplug the power cord immediately and refer servicing to qualified service personn...

Page 5: ...vel for 5 minute cycles twice weekly This will help to maintain a clean chamber It is normal for condensation to be present on the unit during humid summer months If condensation persists despite weather conditions unplug the power cord and refer servicing to qualified service personnel Turn off Cleaning Do not store the unit near chemicals food metals or medication Do not spray water on the main ...

Page 6: ... LCD backlight will be turned off automatically during periods of non use and the Time function is displayed Filter replacement cycle This unit features a filter life cycle display and voice announce ments designed to let you know when it is time to change the filters Every 6 months is best for optimal performance Touch LCD display color backlight The color back light on the LCD display allows you...

Page 7: ...f Hose Tube Suction Cup Assortment of Connectors and Rubber Washers Adjustable Wrench Utility Scissors Plumber s Tape Front View Water Outlet Unit LCD Display Front Cover Door Case Front Case Water Outlet Tube JOG Dial Rear View Hanging Groove Rear Case Power Cord Bottom View Water Inflow Water Outflow Wrench 1 5 6 4 7 2 1 2 3 2 3 1 Model NMP 9000T S11T S13T Drain Faucet Stem Elbow Tube Elbow Drai...

Page 8: ...d quantity discharge System set up Cleaning Volume On Off 1st Filter reset 2nd Filter reset When Alkaline Water 1 2 3 Purified Water H2O Acidic Water 1 2 and Turbo Water icons are selected backlight colors are as follows Alkaline level 1 Light Alkaline water Alkaline level 2 Medium Alkaline water Alkaline level 3 Strong Alkaline water Purified water Creates purified water Acidic level 1 Non Drinka...

Page 9: ... the tip of thefaucet Iftheincludedfaucetdiverterdoesnotfitdirectlytothetipofthefaucet selectanappro priatesizeconnectorandrubberwasher included When connecting the diverter or adapter to the faucet be sure to use plumbing pipe threadsealtape notincluded topreventleaks Connectthefaucetdiverterwiththeappropriateconnectortothefaucet Besureallconnectionsaresecurebutdonotovertightenthem Option A Fauce...

Page 10: ...dy reconnect the power cord How to Install the Drain Faucet As shown above each elbow must flow in In out flow Press the Stem elbow into the Inflow and Tube elbow into the outflow on the bottom of the unit until you hear a click and feel the hose sit firmly in place Connect with the tube elbow connected to the drain hose to the outflow hole on the bottom of the product Connect the drain hose to th...

Page 11: ...ouch the QTY C icon and choose a fixed amount of water 0 5ℓ 1 0ℓ 1 5ℓ 0 5 1 0 1 5 release Select a desired water mode Water outflow stops automatically Fixed quantity discharge function is released after water collection Touch the QTY C button Select the fixed amount of water you need by turning the jog dial Clockwise Increasing by 100ml Max 5L Counterclockwise Decreasing by 100ml Min 200ml Push t...

Page 12: ...Jog dial Once setup is complete press the fixed quantity discharge icon for 3 seconds beeps 2 times Press setup icon for 3 seconds to return to standby screen beeps 2 times Voice says Setup was completed Press setup icon for 3 seconds to return to standby screen beeps 2 times Voice says Setup was completed Press the desired water level button for 3 seconds beeps 2 times 3 Setting the Language Chan...

Page 13: ...outflow after more than 24 hours of non operation Performed after 30 liters of water outflow Performed each time power is turned on Note RTR icon and backlight will flicker before automatic cleaning is performed 1 Auto Cleaning Function 15 Sec Press the RTR button on stand by screen The cleaning Voice message It s under washing do not drink Automatic stop The cleaning will be stop automatically wh...

Page 14: ... switch the unit back on Close Open After initializing the filter press the H2O button and run purified water for 3minutes You are highly recommended to follow this process to use the machine properly ow to Reset the Filters H Replace the target filter After replacing the filter press the F1 icon for 3 seconds Selected filter is initialized and beeps twice Voice announcement 1st Filter initializin...

Page 15: ...es that enhance its performance without prior notification GEM 5000T Max 220W O 5 GEM 9000T 9 Water Cell Plate Materials Product Name Rated Voltage pH Levels Adjustable pH Filters Configuration Filter Life Display Product Size Product Weight Electrolytic Cell Quantity of Poles Power Consumption Operating Pressure Range Available temperature V Water Ionizer 100 130 V 200 240 V 50 60 Hz 4 35ºC 39 95...

Page 16: ...normal Taste Water Outflow Change Incorrect pH levels Unit stops during use Unit leaks Settlement in extracted water The Unit doesn t operate in cleaning mode Only purified water is extracted Filter replacement icon remains on even after filter has been replaced Checkpoints Measures to be Taken Check period of use Check filters for clog Run unit for one minute draining stagnant water Check filter ...