background image

OWNER'S MANUAL

RE

IONATOR

®

WHOLE HOUSE WATER CONDITIONER 

with Triton Electronic Control Valve

Platinum Series

Classic Series

ACTIVATE YOUR WARRANTY

BY REGISTERING YOUR PRODUCT AT

www.watertech.com 

or call 888-254-8412

WQA Gold Seal certified to NSF/ANSI Standards 42 and 44 

for meeting or exceeding industry standards of aesthetic 

chlorine reduction and softening efficiency.

Fusion Series

Summary of Contents for RC32-TM

Page 1: ...latinum Series Classic Series ACTIVATE YOUR WARRANTY BY REGISTERING YOUR PRODUCT AT www watertech com or call 888 254 8412 WQA Gold Seal certified to NSF ANSI Standards 42 and 44 for meeting or exceed...

Page 2: ...use in brine tank Customer knows where to purchase regenerant salt or potassium chloride Customer knows how often to check regenerant salt potassium level Customer knows how much salt or potassium chl...

Page 3: ...heck to make sure the system is plugged in and that there is power at the receptacle If the unit does not respond with power present contact your WaterTech Dealer The manual bypass valve which is loca...

Page 4: ...ndry or other reasons DO contact your WaterTech Dealer if you have any questions about the operation of your system or water quality issues DO enjoy all the benefits of your REIONATOR conditioned wate...

Page 5: ...sin Tank 10 x 47 09 03 1047BLK Resin Tank 10 x 54 09 03 1054BLK Resin Tank 12 x 52 09 03 1252BLK Resin Tank 13 x 54 09 03 1354BLK Brine Tank Assembled 18 x 33 09 04 1833BKC Brine Grid 18 09 04 119 Bri...

Page 6: ...TION PART NUMBER Resin Tank 10 x 35 09 03 1035NB Resin Tank 12 x 35 09 03 1235NB Fusion Cabinet Top 09 05 010 Fusion Cabinet Base 09 05 011 Brine Overflow Elbow 07 05 004 Brine Well Assembly 09 04 244...

Page 7: ...G KRW ZDWHU KHDWHU 7ULWRQ SDVV 9DOYH Typical Plumbing Installation STOP Check local codes for minimum run between Reionator unit and water heater 6 IMPORTANT Brass or plastic yoke assembly not shown i...

Page 8: ...be Insert Drain Elbow Locking Clip 7 CAUTION Never connect drain line directly into drain sewer line or trap Always allow an air gap of at least 25mm 1 inch or 2 pipe diameters between the drain line...

Page 9: ...ng brine Continue to skip cycles by pressing and releasing the REGEN button wait for the motor to stop before pressing REGEN until you reach the Brine Fill position This ensures that water will go to...

Page 10: ...lding run for several minutes to purge the unconditioned water out of the pipes After several minutes take a water sample and test for hardness from the running tap If a hardness test reads soft water...

Page 11: ...s for This is usually referred to as manual regeneration although it is only started manually If there is a period of heavy water usage because of guests or a heavy laundry day for example a manual re...

Page 12: ...l not need to be reprogrammed STEP 1 Press SET CLOCK STEP 2 Current Time hour Set the hour of the day using the 5 or 6 buttons AM PM toggles after 12 Press NEXT to go to step 3 STEP 3 Current Time min...

Page 13: ...ss valve illustrations on the following page Figure 1 Normal Operation Position The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve Water...

Page 14: ...Bypass Valve Illustrations FIGURE 1 NORMAL OPERATION POSITION FIGURE 2 BYPASS OPERATION POSITION FIGURE 3 DIAGNOSTIC MODE POSITION FIGURE 4 SHUT OFF MODE POSITION 13...

Page 15: ...F 110 F or 4 4 43 3 C MAX FLOW TO DRAIN DURING REGENERATION 2 2 gpm or 8 3 l min INPUT VOLTAGE 110 120VAC 60Hz OPERATING VOLTAGE 12VAC 60Hz 14 Model 1 Softening Efficiency Stated Salt Setting Grains P...

Page 16: ...he concentration of the substance in the water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified by NSF ANSI Stan...

Page 17: ...16 Notes...

Page 18: ...17 Notes...

Page 19: ...18 Notes...

Page 20: ...defective under valid warranty coverage as described above Cosmetic damage that does not affect the process functionality of the equipment is not covered WaterTech Industries makes every effort to ens...