IMPORTANT

Safety Instructions • Be sure to read.

This  tank  is  designed  for  use  with  potable 
water,  limited  to  a  maximum  pressure  of  100 

psi and a maximum working temperature of 130°F. Please note: a 
hot water heater or a boiler in a hydronic heating system will heat 
water  hotter  than  130°F  routinely.  Use  a  thermal  expansion  tank 
for  hot  water  overflow  from  a  hot  water  heater,  or  use  an 
expansion  tank  for  hot  water  overflow  in  a  hydronic  heating 
system.  See  the  owner’s  manual  for  your  pump  for  output 
information.

EXPLOSION  OR  RUPTURE  HAZARD

  A  relief 

valve must be installed to prevent pressure in 

excess  of  local  code  requirement  or  maximum  working  pressure 
designated  in  the  Product  Manual,  whichever  is  less.    Do  not 
expose  Product  to  freezing  temperatures  or  temperatures  in 
excess of 200° F.  Do not adjust the pre-charge or re-pressure this 
Product except for any adjustments required at the time of initial 
installation,  especially  if  Product  corroded,  damaged  or  with 
diminished integrity.  Adjustments to pre-charge must be done at 
ambient temperature only.  Failure to properly size the Product or 
follow  these  instructions  may  result  in  excessive  strain  on  the 
system  lead  to  Product  failure,  serious  or  fatal  personal  injury, 
leakage and/or property damage.

This  Product,  like  most  Products  under 
pressure, may over time corrode. Weaken and 

burst or explode, causing serious or fatal injury, leaking or flooding 
and/or property damage.  To minimize risk, a licensed professional 
must install and periodically inspect and service the Product.  A 
drip  pan  connected  to  an  adequate  drain  must  be  installed  if 
leaking or flooding could cause property damage.  Do not locate 
in an area where leakage of the tank or connections could cause 
property damage to the area adjacent to the appliance or to lower 
floors of the structure.

Chlorine  &  Aggressive  Water

:  The  water 

quality  can  significantly  influence  the  life  of 

this Product.  You should test for corrosive elements, acidity, total 
solids  and  other  relevant  contaminants,  including  chlorine  and 
treat your water appropriately to insure satisfactory performance 
and prevent premature failure. 

Note:

    Inspect  for  shipping  damage  and  notify  freight  carrier  or 

store  where  purchased  immediately  if  damage  is  present.    To 
avoid risk of personal injury and property damage, if the product 
appears to be malfunctioning or shows signs of corrosion, call a 
qualified professional immediately.  Current copies of the Product 
manual  can  be  viewed  at  www.waterworkerdiy.com.    Use  proper 
safety equipment when installing.

As in all plumbing products and water storage 

vessels,  bacteria  can  grow  in  this  Product, 

especially during times of non-use.  Consult your local plumbing 
professional regarding any steps you may wish to take to safely 
disinfect your home’s plumbing system. 

DANGER!  EXPLOSION  HAZARD,  WHEN  THE 
WELL  TANK  HAS  BEEN  IN  SERVICE  AND  A 

CHANGE TO A HIGHER PRE-CHARGE PRESSURE IS NECESSARY 

DUE  TO  A  REQUIRED  CHANGE  IN  THE  PRESSURE  SWITCH 
SETTING,  FAILURE  TO  FOLLOW  INSTRUCTION  MANUAL  CAN 
CAUSE  A  RUPTURE  OR  EXPLOSION,  POSSIBLY  CAUSING 
SERIOUS OR FATAL INJURY, AND/OR PROPERTY DAMAGE.

DO NOT ADJUST THE PRE-CHARGE PRESSURE IF THERE HAS 
BEEN A REDUCTION OF THE PUMP CYCLE TIME OR THE PRE-
CHARGE  PRESSURE  COMPARED  TO  ITS  INITIAL  SETTING.  
THIS  IS  BECAUSE  REDUCTION  IN  PUMP  CYCLE  TIME  CAN 
RESULT  FROM  LOSS  OF  TANK  AIR  PRESSURE  WHICH  IN 
TURN  CAN  MEAN  THERE  MAY  BE  INTERNAL  CORROSION 
AND ANY RE-PRESSURIZATION OR ADDITIONAL PRESSURE 
COULD  RESULT  IN  RUPTURE  OR  EXPLOSION,  AND/OR 
PROPERTY DAMAGE. 

MAXIMUM WORKING PRESSURES.  

Every well 

tank  is  air  tested  to  125  psig,  the  maximum 

working pressure for the well tank line.  Should pressures exceed 
125 psig, proper selection and sizing of an ASME constructed well 
tank should be made.

RELIEF  VALVE  REQUIRED

.    A  relief  valve 

should  be  installed  which  is  set  to  open  at  

excessive pressures (75 psig or more).  This will protect the well 
tank  and  other  system  components  should  the  pressure  switch 
malfunction and fail to shut the pump off.  The relief valve should 
be  installed  at  the  connection  of  the  well  tank  to  the  system 
piping  and  have  a  discharge  equal  to  the  pump’s  capacity  at 
75  psig.  At  least  once  every  3  years  or  if  discharge  is  present,  a 
licensed contractor should inspect the temperature and pressure 
relief  valve  and  replace  if  corrosion  is  evident  or  the  valve  does 
not  function.  FAILURE  TO  INSPECT  THIS  VALVE  AS  DIRECTED 
COULD  RESULT  IN  UNSAFE  TEMPERATURE  OR  PRESSURE 
BUILD-UP WHICH CAN RESULT IN PRODUCT FAILURE, SERIOUS 
INJURY OR DEATH AND/OR SEVERE PROPERTY DAMAGE AND 
VOID THE PRODUCT WARRANTY.

For your safety, the information in this manual 
must  be  followed  to  minimize  the  risk  of 

electric  shock,  property  damage  or  personal  injury.    Properly 
ground to conform with all governing codes and ordinances 

Do not use this tank for chemicals, solvents, petroleum products, 
acids,  or  any  fluids  other  than  potable  water.  This  can  cause 
premature failure due to corrosion.

Make sure that the pressure switch in your well system is set low 
enough to shut off the pump. If all of the faucets and valves are 
closed  in  your  plumbing  system  and  the  pressure  switch  setting 
is too high, the pump can run continuously without moving water 
through the system. This could damage or burn out the pump.

CALIFORNIA  PROPOSITION  65  WARNING!

  

This product contains a chemical known by the 

State of California to cause cancer and to cause birth defects or 
other  reproductive  harm.  (California  Installer/Contractor  - 
California law requires that this notice be given to consumer/end 
user of this product.) For more information:  www.waterworkerdiy.
com/prop65.htm

Summary of Contents for HT2B

Page 1: ...At least once every 3 years or if discharge is present a licensed contractor should inspect the temperature and pressure relief valve and replace if corrosion is evident or the valve does not functio...

Page 2: ...lastic hose to a length long enough to steer water clear of whatever you don t want to get wet Insert one end of the plastic hose over the end of the 1 2 plastic hose barb Screw the barb hose assembly...

Page 3: ...sional regarding any steps you may wish to take to safely disinfect your home s plumbing system DANGER EXPLOSION HAZARD WHEN THE WELL TANK HAS BEEN IN SERVICE AND A CHANGE TO A HIGHER PRE CHARGE PRESS...

Page 4: ...ranty also does not cover repair or replacement costs not authorized in advance by WATER WORKER THESE WARRANTIES ARE GIVEN IN LIEU OF ALL OTHER EXPRESS WARRANTIES NO WATER WORKER REPRESENTATIVE OR ANY...

Page 5: ...a pompe 75 psi manom triques Au moins une fois tous les 3 ans ou s il y a pr sence d coulement un entrepreneur licenci devrait v rifier la temp rature et inspecter la soupape de surpression et la remp...

Page 6: ...Ins rez une extr mit du boyau de plastique par dessus l extr mit du raccord cannel de plastique de 12 7 mm 1 2 po Vissez l assemblage du raccord cannel dans la soupape de surpression Bien serrez avec...

Page 7: ...suivre pour d sinfecter s curitairement votre plomberie r sidentielle DANGER RISQUE D EXPLOSION LORSQUE LE R SERVOIR POUR PUITS A T EN SERVICE ET QU UN CHANGEMENT UNE PRESSION DE PR CHARGE SUP RIEURE...

Page 8: ...S AUTRES GARANTIES EXPRESSES AUCUN REPR SENTANT DE WATER WORKER OU TOUTE AUTRE PARTIE N EST AUTORIS TABLIR UNE GARANTIE AUTRE QUE CELLE EXPRESS MENT CONTENUE DANS LE PR SENT CONTRAT DE GARANTIE Limita...

Page 9: ...e la bomba de 75 psig Al menos una vez cada 3 a os o cuando se descargue un contratista autorizado debe inspeccionar la v lvula disipadora de presi n y temperatura y reemplazarla si hubiera corrosi n...

Page 10: ...ara redireccionar el agua lejos de lo que no quiera que se moje Inserte un extremo de la manguera pl stica sobre el extremo del conector de la manguera pl stica de 1 2 Enrosque el conjunto del conecto...

Page 11: ...a su plomero profesional local acerca de los pasos que puede tomar para desinfectar de forma segura el sistema de tuber as de su hogar PELIGRO PELIGRO DE EXPLOSI N SI SE HA REALIZADO EL SERVICIO T CN...

Page 12: ...RA OFRECER GARANT AS ADICIONALES A LAS CONTENIDAS EXPRESAMENTE EN ESTE ACUERDO DE GARANT AS Limitaciones adicionales a la garant a TODAS LAS GARANT AS IMPL CITAS INCLUIDAS LAS GARANT AS IMPL CITAS DE...

Reviews: