QUICK GUIDE
READ THE PUMP OWNER’S MANUAL!
The improper use of this pump could result in serious injuries
Diesel is flammable. Refuel in a well-ventilated area,
with the engine stopped.
Always allow enough time, after stopping the unit,
for proper cooling of these parts and surrounding areas.
Exhaust gas contains carbon monoxide which
is poisonous to humans. Avoid inhalation of
exhaust gas.
as well as damage to the unit. Read the
BB-4 Owner’s
Manual
before using your BB-4 pump unit and follow the
safety instructions in this Quick Guide.
REFUEL ENGINE WITH CARE
.
NEVER RUN THE ENGINE IN A CLOSED
OR CONFINED AREA
.
NEVER TOUCH ANY EXHAUST OR
COOLING SYSTEM PARTS WHILE ENGINE
IS RUNNING
.
EQUIPMENT DAMAGE PREVENTION:
•
Flush the pump with fresh water if the pump has been used to pump salty, brackish, high mineral content water,
water containing debris, or foam injected water. Check that debris is cleared before using the pump again.
Always draft water using a suction hose strainer.
•
Parts
Identification
A.
Priming cap
B.
Pump intake (suction)
C.
Pump drain port
(not
shown)
D.
Pump discharge
E.
Quick release pump
clamp
F.
Radiator coolant cap
G.
Coolant overflow
(not
shown)
H.
Muffler
I.
Throttle
(not shown)
J.
Oil fill plug
K.
Oil dipstick
(not shown)
L.
Fuel valve
(not shown)
M.
PMSCP-DIESEL control
panel*
* Please refer to your control panel
user instructions for installation
and wiring procedures
A
B
D
E
F
M
C
G
H
J
K
L
I