16
Setting The Controller - Continued
7) POWERCLEAN™
The powerClean™ feature is a service/maintenance step for water supplies that have an excessive
amount of iron. Activating this feature is a simple push of the powerClean™ button on the controller.
A yellow light indicates that the powerClean™ feature is activated. The appliance will regenerate
every other day with five pounds of salt. Leave the powerClean™ feature on for a minimum of two
weeks. The frequent regeneration will elimate iron buildup in the resin bed. The use of salt with an
iron cleaning agent or iron out cleaner is recommended for continuous use as a preventive measure
against iron fouling of the resin bed. To deactivate this feature, simply press the powerClean™ but-
ton. Use this feature every six months as a part of your routine maintenance procedure to insure a
long service life for your water treatment appliance. See figure 9.
DELAYED REGENERATION*
. . . If you wish to regenerate at a specific time.
NOTE: time is set in military time (EXAMPLE: 2 am = 0200.)
1) Enter Setting Number as described in "Demand Regeneration" procedure.
2) Set current time of day in military time to nearest hour.
-Step A: Press "SET" button.
-Step B: Press Immediate Recharge button (status indicator light on; not blinking.)
-Step C: Press "SET" button until current time of day appears in the display.
Wait until display returns to "Gallons Remaining" - approximately 10 seconds.
Then proceed to set desired time of regeneration. (EXAMPLE: if current time of
day is 4:20 pm, set on 16 which represents 1600 military time.) NOTE: if more than 10
seconds lapse between any of the following steps, the display will return to the start
point which is "Gallons Remaining."
3) Set desired time of regeneration in military time to nearest hour.
- Step A: Press "SET" button.
- Step B: Press Immediate Recharge button 2 times (status indicator light out.)
- Step C: Press "SET" button until desired time of regeneration appears in the display.
After Step C, the display will return to gallons remaining and it is ready for service.
(EXAMPLE: if desired regeneration time is 2:00 am, set on 2 which represents 0200
military time.)
NOTE: if display starts flashing, you have inadvertently held down the Immediate Recharge button
for more than 5 seconds and placed the unit into Immediate Regeneration. Let the appliance finish
the regeneration sequence, or advance through the cycles as previously described in paragraph 3,
page 15.
NOTE: if you desire to return unit to Demand Regeneration when the controller is in Delayed
Regeneration, simply set the time of regeneration to "88" (see Delayed Regeneration, Step 3.)
*
cityBoss
®
for municipally-supplied water operates on Demand Regeneration only.