17
Advanced Settings For The 3 Button Controller
Adjustable Settings.
Your electronic control has four manual adjustable settings. The
adjustments are:
1. Display water remaining in gallons or litres
2. 72-96 hour forced regeneration (on/off) every 4
days minimum regeneration**
3. Backwash #1 cycle length
4. Salt refill cycle length
Making Adjustments.
Remove the 4 housing backplate screws. The switches are
located in the upper left of the circuit board. The switches can
easily be adjusted using a small, flat blade screwdriver.
The switches are "ON" when in the up position and "OFF"
when in the down position.
Switch Descriptions.
Switch #1 - LANGUAGE
ON = Display water remaining in litres
* OFF = Display water remaining in gallons
Switch #2 - 72-96 HOUR FORCED REGENERATION
* ON = 72-96 hour forced regeneration activated
(every 3-4 days minimum regeneration)
OFF = 72-96 hour forced regeneration deactivated
Switch #3 - BACKWASH #1
ON = 3 minute backwash #1
OFF = 1 minute backwash #1
Switch #4 - BACKWASH #1
ON = 7 minute backwash #1
* OFF = no value
Switches 3 & 4 are used together to set the Backwash #1 cycle time.
Switch #5 - SALT SETTING
ON = 5.0 minute Brine Refill (7.0# Salt). Brine
draw is increased by 10 minutes. Unit
capacity - 27,000 at 1 cu. ft. (
BigBoss)
OFF = 2.6 minutes Brine Refill (3.8# Salt) Unit
capacity - 17,800 grains at .7 cu. ft. (
waterBoss)
* Factory Settings
** If the unit does not regenerate within 72 hours, it will automatically
regenerate at the next time of regeneration (TOR), not to exceed 96 hours
1 2 3 4 5
ON
OFF
Switch #3 Switch #4 Backwash #1 Time
OFF OFF 1 0
ON OFF
3 1-2
OFF ON 7 2-3
ON ON
10 4-10
Backwash #1 Switch Setting Chart
powerClean
™
overrides switches 2-5