Page 1: ...waterBoss 4343 S Hamilton Road Groveport Ohio 43125 Water Softeners waterBoss cityBoss BigBoss Filters Iron Filter Carbon Filter Acid Netralizing Filter Click in this page to return to water softener...
Page 2: ...this manual which will help you get the maximum benefit and enjoyment from your particular model We urge you to read this information carefully now and any time a malfunction may occur In most cases t...
Page 3: ...SHOOTING 32 cityBoss HARDNESS SETTING CHART 34 97WB ANF ACID NETRALIZING FILTER START UP PROCEDURES 35 97WB IF IRON FILTER START UP PROCEDURES 36 97WB CF CARBON FILTER START UP PROCEDURES 37 PARTS APP...
Page 4: ...ing the HelpLine please have this guide and the serial number of your appliance available Your serial number may be found on top of your valve assembly See figures 2 3 Date of Installation ___________...
Page 5: ...ins impurities that can plug up the injector assembly 2 You may use a salt substitute such as potassium chloride in place of water conditioner salt If you start with water conditioner salt you can swi...
Page 6: ...siphoning the installer must provide an adequate air gap or a siphon break See figure 1 5 Electricity The transformer supplied is a standard 120 volt 60 cycle A C for USA or 220 volt 50 cycle A C for...
Page 7: ...0 degress for Iron Filter Please see specification on pages 40 41 3 Do not allow soldering torch heat to be transferred to valve components or plastic parts 4 Do not overtighten plastic fittings 5 Do...
Page 8: ...ystem also provides access to untreated water when required i e for lawn and gardening purposes Also see figures 4 through 6 Caution If less than 10 feet of pipe connect the water treatment appliance...
Page 9: ...e drain line 1 2 inside diameter cannot be reduced in size Figure 2 Figure 3 PLUMBING CONNECTIONS S N 29350185 When calling the HelpLine please have this guide and the serial number available From 8 a...
Page 10: ...EST call 1 800 437 8993 Your serial number may be found on top of your valve assembly See figures 2 3 Figure 4 Bypass Valves Figure 5 Par t 93884 push pull for service or bypass This part may be avail...
Page 11: ...e and the serial number available From 8 am to 5 pm EST call 1 800 437 8993 Your serial number may be found on top of your valve assembly See figures 2 3 PLUGGING IN TRANSFORMER Do not plug transforme...
Page 12: ...ber may be found on top of your valve assembly See figures 2 3 Figure 9 Figure 10 ADDING SALT TO THE BRINE CABINET waterBoss BigBoss and cityBoss softeners only Refer to page 36 for Iron Filter start...
Page 13: ...n bed and cleans the sediment filter 2 Brine Brine is drawn out of the brine cabinet and up through the media tank cleaning the resin bed and releasing accumulated hardness and iron 3 Slow rinse A slo...
Page 14: ...number available From 8 am to 5 pm EST call 1 800 437 8993 Your serial number may be found on top of your valve assembly See figures 2 3 Figure 11 1 First up flow backwash 2 Brine 3 Slow Rinse 4 Secon...
Page 15: ...itioner Exhaust Pattern Much of your resin could be wasted Exhausted Resin Regenerated Resin Water Unused Resin Directional Flow Screen Directional Flow Screen Exhaust Pattern assures more usable resi...
Page 16: ...in line must be equal in height or lower than the control valve See figure 1 All overhead drains for filter installations must be 3 4 I D 3 Flushing Before placing your waterBoss appliance in service...
Page 17: ...ill 25 grains per gallon call your HelpLine Or contact the company below to test for hardness iron and pH WATERSCREEN National Testing Laboratories Inc 1 800 458 3330 9 am 5 pm EST If you feel you hav...
Page 18: ...g regeneration The read out will flash with the cycle number The flashing regeneration numbers are 01 First Backwash 02 Brine Slow Rinse 03 Second Backwash 04 Brine Refill 05 Service See pages 11 and...
Page 19: ...ght on not blinking Step C Press SET button until current time of day appears in the display Wait until display returns to Gallons Remaining approximately 10 seconds Then proceed to set desired time o...
Page 20: ...ns Switch 2 72 96 HOUR FORCED REGENERATION ON 72 96 hour forced regeneration activated every 3 4 days minimum regeneration OFF 72 96 hour forced regeneration deactivated Switch 3 BACKWASH 1 ON 3 minut...
Page 21: ...1 93582 CB Computer Control cityBoss 1 93582 IF Computer Control Iron Filter 1 93582 CF Computer Control Carbon Filter 1 93582 NF Computer Control Acid 1 Neutralizing Filter 6 C0700 2 pc Overflow 1 7...
Page 22: ...d Parts When calling the HelpLine please have this guide and the serial number available From 8 am to 5 pm EST call 1 800 437 8993 Your serial number may be found on top of your valve assembly See fig...
Page 23: ...Tank Assembly 1 waterBoss cityBoss empty 95505 ResinTank Assembly BigBoss empty 1 97505 Greensand Media Tank complete 1 97506 Media Tank Assembly Filters empty 1 97507 Carbon Media Tank complete 1 975...
Page 24: ...e have this guide and the serial number available From 8 am to 5 pm EST call 1 800 437 8993 Your serial number may be found on top of your valve assembly See figures 2 3 Figure 13 See Page 38 See Page...
Page 25: ...jector Cap 1 6 90807 Injector Screw 4 7 93810 Injector Screen 1 93501 Injector Assembly 1 Includes all above items Note When working on the injector assembly make sure part 2 aligns properly with the...
Page 26: ...e please have this guide and the serial number available From 8 am to 5 pm EST call 1 800 437 8993 Your serial number may be found on top of your valve assembly See figures 2 3 Figure 14 Part Number 9...
Page 27: ...igure 15 I O Adapter Assembly FIGURE PART DESCRIPTION QUANTITY 1 93227 3 4 IO Adapter 1 2 93858 Turbine Sensor Assembly 1 3 90232 Turbine Sensor Cap 1 4 90522 Turbine Assembly 1 5 93838 O Ring 2 6 932...
Page 28: ...ilable From 8 am to 5 pm EST call 1 800 437 8993 Your serial number may be found on top of your valve assembly See figures 2 3 Figure 15 Part Number 93505 I O Adapter Assembly Contains All Of The Abov...
Page 29: ...217 Drive Motor 12V 1 3 93216 Piston Slide 1 4 93217 Piston Slide Cam 1 5 93219 Piston Slide Cam Cover 1 6 95521 Magnetic Disc 1 7 90809 Screw self tapping 2 8 93514 A Brine Valve Housing Assembly 1 9...
Page 30: ...ide and the serial number available From 8 am to 5 pm EST call 1 800 437 8993 Your serial number may be found on top of your valve assembly See figures 2 3 Figure 16 Part Number 95301T This assembly d...
Page 31: ...erial number may be found on top of your valve assembly See figures 2 3 Figure 17 Brine Valve Housing Assembly FIGURE PART DESCRIPTION QUANTITY 1 93511 A Housing 1 2 93243 Housing Cap 1 3 90521 Piston...
Page 32: ...serial number available From 8 am to 5 pm EST call 1 800 437 8993 Your serial number may be found on top of your valve assembly See figures 2 3 Figure 17 Part Number 93514 A Brine Valve Assembly Cont...
Page 33: ...yBoss 1 93882 25 75 Air Check Draw Tube BigBoss 1 4 93202 Support Panel 1 93202 F Support Panel Filters 1 NOTE See Appendix on page 39 for Iron Filter Safty Shutoff Assembly 30 When calling the HelpLi...
Page 34: ...and Parts Figure 18 When calling the HelpLine please have this guide and the serial number available From 8 am to 5 pm EST call 1 800 437 8993 Your serial number may be found on top of your valve asse...
Page 35: ...gnet on the sensor chip If light glows clean or replace turbine If no light replace sensor Repair the leak Run water Verify flashing light Plug in transformer Check power source Make sure outlet is no...
Page 36: ...circuit board fig 9 Computer control not attached properly Foreign object in valve body Broken valve assembly Motor running Magnet disc not turning pages 26 27 Restricted frozen or pinched drain line...
Page 37: ...Is Your Setting Is 1 2 2 3 3 5 4 6 5 7 6 9 7 10 8 12 9 13 10 14 11 16 12 17 13 19 14 20 15 21 16 23 17 24 18 26 19 27 20 28 21 30 22 31 23 33 24 34 25 35 When calling the HelpLine please have this gui...
Page 38: ...ore placing this filter in service it will be necessary to backwash the filter to remove media fines in the filter bed To backwash the filter push and hold the immediate recharge button until the cont...
Page 39: ...push and hold the immediate recharge button until the controller indicates cycle 01 flash ing After 33 minutes the filter will return to service mode and display 03 or 04 solid NOTE This filter should...
Page 40: ...he operating limits outlined on page 41 of your installation and service manual Failure to comply with these specifications will cause poor backwash results and possibly a malfunc tion of the control...
Page 41: ...2 3 Drain End Cap Assembly FIGURE PART DESCRIPTION QUANTITY 1 90268 Drain End Cap Threaded 1 2 H2086 5 0 Drain Line Flow Control Button 1 H2086 3 0 Drain Line Flow Control Button 1 3 90267 Retainer 1...
Page 42: ...ttom Fill Plug Assembly With O Rings 1 2 90819 Bottom Fill Plug O Rings 2 Retainer Sleeve Steel Gripper Nut 3 8 Rigid PVC Pipe Complete Assembly Retainer Sleeve 3 8 Polytube Nut Plastic Insert Steel G...
Page 43: ...4 MPT 3 4 MPT 3 4 MPT 85 lbs 105 lbs 85 lbs Maximum compensated hardness grains Maximum ferrous iron reduction Minimum pH Media type and amounts Salt usage lbs Capacity Maximum water temperature Mine...
Page 44: ...e required gpm Controller type Regeneration time minutes Water used per regeneration gallons Frequency of regeneration days Salt Storage Height in Footprint in Electrical Rating Plumbing Connections S...
Page 45: ...substances in the sys tem specifications other special treatment of the water supply must be used to remove these substances before they enter this product Otherwise waterBoss shall have no obligatio...
Page 46: ......
Page 47: ......
Page 48: ...orm 93966 RV1001HQW U L has the third party listings In Business Since 1956 Listed and tested under NSF Standard 44 for Softening Performance Barium Reduction and Radium 226 228 Reduction Water soften...