Section 3 – Operating Instructions
20
3.10 Chemflo Display Messages
The
Chemflo
features a user-friendly text display. As well as showing the pH and ORP readings, it
is also used to provide status and alarm messages, as per the following example.
The meanings of the messages are detailed below…
Status/Alarm Message
Meaning
OK
Reading is within Set Point and no chemical dosing is required.
High or Low
Reading is outside Set Point and chemical is being added.
Stby
Unit is in Standby mode. No dosing of chemicals will occur. See
section 3.3.
sOFF
Emergency ShutOFF timer has been tripped. See section 6.2.
OFF
+
OVR
for reading
Dosing Pump is off-line, due to the reading being Over-Range.
Alarm
Reading is outside the Alarm margin. See section 6.4
Pump
Dosing Pump High Current Error. See section 4.3
Waiting for Pump
Re-Start Time
Whenever the pool pump is switched off by the
Chemflo
, the unit
will wait a minimum of 10 seconds before switching it back on. If
any function is used less than 10 seconds after the pool pump was
last switched off, this message is displayed.