Section 8 – Chemflo Specifications
32
Section 8. – Chemflo Specifications
Range Resolution Accuracy
ORP
500 to 999 mV
1 mV
±1 mV
pH
5.00 to 9.00 pH
0.01 pH
±0.02 pH
Calibration
pH Asymmetry Range
: -1.00 to +1.00 pH
Calendar Clock
x
24 Hour Calendar Clock.
x
Tests for valid day of the month when setting (eg. 31/09/99 is not valid).
x
Adjusts for leap years.
Peristaltic Pumps
x
The
Chemflo
has 2 x built-in Peristaltic Pumps for ORP and pH control.
x
Chemical resistant Santoprene pump tube.
x
Standard small pump tube produces 1.8 Litres / Hour
Large pump tube produces 6.1 Litres / Hour (High demand pools only).