Section 9 – Custom Settings Menu
39
9.6 ShutOFF Times
9.6.1 Setting the ShutOFF Times
1. Access the Custom Settings Menu. See section 9.1
2. Press until “
o
ShutOFF
” is selected and press
.
3. The
Chemflo
now allows you to enter the maximum time for which the ORP pump will operate
without getting back to within the limit…
ORP ShutOFF
70mins
np
Enter
Use the
and
keys to set the required time, from 1 to 240 minutes.
Press and hold the
or
key to scroll rapidly.
4. Press to save the ShutOFF timer setting for the ORP pump.
Press
to quit and retain the current setting.
5. If was pressed above, the
Chemflo
will now allow you to enter the maximum time for
which the pH pump will operate without getting back to within the limit…
pH ShutOFF
30mins
np
Enter
Use the
and
keys to set the required time, from 1 to 240 minutes.
Press and hold the
or
key to scroll rapidly.
6. Press to save the ShutOFF timer setting for the pH pump.
Press
to quit and retain the current setting.
9.6.2 Default ShutOFF Times for Pool Sizes
The following table details the default ORP and pH ShutOFF times for the various pool sizes…
Spa 20,000
Litres
50,000
Litres
100,000
Litres
Tube Size
Small Large Small Large Small Large Small Large
ORP ShutOFF Time
45 mins 15 mins 70 mins 20 mins 70 mins 30 mins
120 mins
60 mins
pH ShutOFF Time
30 mins
5 mins 30 mins 10 mins 30 mins 10 mins 45 mins 20 mins
9.6.3 Disabling the Emergency ShutOFF Timer
Extreme caution should be exercised when disabling the ShutOFF timer, as this could allow an
entire drum of Chlorine and/or Acid to be dosed into the pool in the event of a malfunction.
Overdosing Acid can cause serious pool, equipment and health hazards.
To disable the ShutOFF timer, set the ShutOFF time to 0 minutes.