Section 2 – Installation
8
2.3 Fit Tubing into Chemical Drums
Insert the suction tubing
through the chemical
drum lid supplied and fit
the drum weight, as per
the diagram below. Be
sure to use the correct
type of chemical
resistant drum. Your pool
professional can advise
on this. For installations
where the lid provided is
not compatible with the
container, drill a 1/2” or
13mm hole into the lid of
the container and fit the
compression fitting. Drill
a second 2mm diameter
vent hole to avoid
suction build-up.
IMPORTANT INFORMATION REGARDING ACID
x
Always use dilute Hydrochloric Acid.
x
Add 5 Litres of Acid to 20 to 25 Litres of water.
x
NEVER ADD WATER TO ACID
x
Using concentrated acid may damage your equipment and void the
warranty
2.4 Fit Tubing to Dosing Pumps
Insert the suction tubing
from the chemical drum
to the left hand side
compression fitting of the
dosing pump. Screw the
retaining nut into place
firmly, ensuring the tube
is securely anchored.
Repeat for the tubing on
the right hand side of the
pump.
Ensure that the
Chlorine drum is
connected to the
Chlorine pump, and the
Acid drum is
connected to the Acid
pump.