• Submerge the light in the water before switching it on, to avoid over heating.
• Wind sufficient cable behind light to allow for removal from the pool for servicing.
• Light must be installed not more than 600mm below top of coping, to allow for removal from pool for
servicing.
• Surrounding area has to be clear and unencumbered to allow for adequate space to service the light.
• Cutting an underwater section of cable will void the warranty unless done so in conjunction with the
Underwater Light Replacement Kit.
CaUtion
INSTALLATION CONCRETE WALLED POOLS
a) Set conduit for light power
cord as normal at 550mm
below top of coping.
b) Render or marble sheen
Wall Ring in wall. Make sure
the word “Top” is up.
c) Attach under water light
Twist Lock Adaptor to Wall
Ring with screws.
d) Wind power cord loosely
around back of light.
Ensure it is properly
retained within securing
clips.
e) Feed remaining power cord through conduit.
f) Fit the light to the under water Twist Lock Adaptor by aligning the lights locking lugs with the locking
slots in the Twist Lock Adaptor. Turn the Twist Lock Adaptor clockwise fully into the locked position.
Fix light to Twist Lock Adaptor with screw at the top to prevent unlocking.
INSTALLATION VINYL LINER POOLS
a) Drill a 32mm hole in the pool wall (Vinyl / fibreglass conversion kit # 266022 required) at 550mm below
top of coping. This is where the cable will pass through the wall. See figure 2.
b) Mark fixing holes for Gland Plate and Wall Brackets. Drill holes to suit screws supplied.
c) After fitting liner, slit liner at 32mm hole position. Fit Gland Plate and Wall Bracket.
d) Wind cord loosely around back of light catching it in clips.
e) Insert gland nut, rubber washer and then plastic seal ring onto the power cord and feed the power cord
through the gland plate.
f) Tighten gland nut onto gland plate.
g) Fit light to Wall Bracket by sliding the light downwards until the clip and hook engage.
Fix with screw at top.
INSTALLATION FIBREGLASS POOLS
a) Drill a 28mm hole in the pool wall (Vinyl / fibreglass conversion kit # 266022 required) at 550mm below
top of coping. This is where the cable will pass through the wall.
b) Cover the back of the Gland Plate with Silicone Sealant and insert the boss of the Gland Plate into the
drilled hole.
Figure 1
TWIST LOCK ADAPTOR FOR
UNDER WATER LIGHT
PUNCH OUT FOR VINYL