OXISWIM MANUAL
P a g e
34 | 45
9.5
Hydroxyl Radical Generator (HRG)
Please refer to the instruction manual located in the packaging of the Hydroxyl Radical
Generator. The catalytic component of the HGR should be replaced every 12 months.
Please use the following part number to order it from Waterco using part number 3533000
Hydroxyl Catalyst Replacement.
9.6
Peristaltic Pumps
The squeeze tubes of the peristaltic pumps should be replaced everyone (1) year depending
on the amount of chemical being used. The roller blocks should be replaced at least every
two years. The higher the usage, the more often replacement is required.
9.6.1
Changing the tube without dismantling the rotor
Important: Use original Oxiswim squeeze tubes only!
Important: Never grease the tube!
Figure 9.1
Figure 9.2
Figure 9.3
Figure 9.4
Caution: Before changing the tube always ensure, that the tubes
don't contain the residual chemical. The acid may cause severe
injuries to your eyes and your skin. Wear protective glasses and
gloves and protect the environment from escaping dosage
products with a cloth if necessary.
Caution: The turning rotor can cause dangerous contusions!
Always first ensure that the pump stays disconnected from the
operational voltage during the changing of the tube (Switch off
power to the Electrochlor!)
Summary of Contents for OXISWIM
Page 1: ...D U A L S A N I T I S A T I O N Installation and Operation manual Version 1 1 3 December 2022 ...
Page 11: ...OXISWIM MANUAL P a g e 11 45 INSTALLATION AND COMMISSIONING ...
Page 15: ...OXISWIM MANUAL P a g e 15 45 Oxiswim Typical Installation Layout ...
Page 28: ...OXISWIM MANUAL P a g e 28 45 OPERATION AND MAINTENANCE ...