Pool Heat Pump
| Pg 12
OPERATION OF YOUR POOL HEAT PUMP
To Start the Pool Heat Pump
Press the button
ON/OFF
on the electronic control to start the pool heat pump. The
temperature display shows the pool water temperature flowing in your pool heat pump and
the fan motor starts (fan blades turn) but the compressor does not start.
The temperature display flashes until the compressor starts and when the timer will
complete its cycle of 5 minutes. After 5 minutes, the compressor starts and the temperature
on the display stops flashing.
You can now program the desired temperature for the pool water.
To Stop the Pool Heat Pump
The pool heat pump can be stopped by pressing the
ON/OFF
button once.
To Check and Adjust Temperature Settings
To program the desired water temperature, press
BOTH
the
UP
and
DOWN
arrow keys at
the same time until the temperature displayed changes degree, then release them.
Press the
UP
or
DOWN
arrow to program the desired temperature. The temperature setting
will automatically flash and will be saved. The display temperature will be reverting back to
the pool water temperature when all keys remain untouched for 5 seconds.
To change the temperature display from Fahrenheit (˚F) to Celsius (˚C), press the button
˚C/˚F
. The led below the
˚F
or
˚C
will be lit to indicate the current selection.
Note: The pool heat pump will stop working when the programmed temperature is reached.
OPERATION OF YOUR POOL HEAT PUMP
Pool Solar Blanket
A pool solar blanket should be used whenever possible. Blankets minimize heat loss and
conserve heat in your pool. Un-blanketed pool loses 2-3 times more heat than a blanketed
pool.
STRONGLY RECOMMANDED AT THE BEGINNING AND END OF SEASON
Defrost Cycle
When any of the following conditions occur, the electronic control of your unit will activate a
defrost mode until all frost from the evaporator has melted. Condensation of water on the
evaporator coil tends to frost up quicker when the following occur.
1. When atmospheric conditions are as stated on previous page;
2. When the evaporator is dirty;
3. When installation clearances are not respected.
Defrost is activated for a laps of time between 3 to 20 minutes.
Electronic Control with Diagnostics and Reversible
(XLR)
Electronic Control with Diagnostics
Reversible (XLR) Electronic
Control with Diagnostics
Electronic Control
with Diagnostics