8
Table III–Recommended Fusing Data, 115 Volt 60 Hz Motors.
Branch
Pump
Motor
Full Load
Circuit Breaker
Model No.
H.P.
Amps
Rating (Amps)
JWPA5DC-2A3
3/4
9.4
15
JWPA5EC-2A3
1
11.9
15
JWPS5FC-2A3
1-1/2SPL
11.9
15
17290-J1002 (2-Speed)
1 – 1/6
11.6/3.3
15
NOTICE:
Values given are for pump motor only. Do not put
any other accessories on this circuit.
Table IV–Recommended Fusing Data, 115 Volt 60 Hz Single
Speed Motors.
Branch
Pump
Motor
Full Load
Circuit Breaker
Model No.
H.P.
Amps
Rating (Amps)
ABGS4EL-A2
1SPL
9.0
15
JWPA5DL-2A1, -2A2
3/4
9.0
15
JWPS5EL-A2
1SPL
9.0
15
JWPA5EL-2A1, -2A2
1
12.0
15
JWPAS5F-2A4U
1-1/2 SPL
12.0
15
JWPS5FL-A2
1-1/2 SPL
12.0
15
JWPA5FL-2A1, -2A2
1-1/2
16.0
20
Table V–Recommended Fusing Data, 230 Volt 60 Hz Motors.
Branch
Pump
Motor
Full Load
Circuit Breaker
Model No.
H.P.
Amps
Rating (Amps)
JWPA5E-230A2
1
6.1
15
Table VI–Recommended Fusing Data, 115 Volt 60 Hz 2-Speed
Motors.
Branch
Pump
Motor
Full Load
Circuit Breaker
Model No.
H.P.
Amps
Rating (Amps)
JWPA5YEL
1 / 1/8
11.7/3.39
15
JWPA5YFL
1-1/2 / 1/6
16.6/3.6
25
NOTICE
Values given are for pump motor only. Do not put any
other accessories on this circuit.
Startup/Operation
(See Figure 9)
Hazardous suction. Can trap and tear hair
or body parts and can cause drowning. Do not block
pump suction. Small children using pool must ALWAYS
have close adult supervision.
R
E
C
IR
C
U
L
A
T
E
BA
CK
WA
SH
CL
OS
ED
W
IN
T
E
R
IZ
E
W
A
S
T
E
FILTER
R
IN
S
E
Valve Setting
Purpose/Flow
FILTER
Normal filtration and
vacuuming; water goes
through filter to pool.
RINSE
For initial startup cleaning
and sand bed leveling
after backwash; water goes
through filter to waste.
RECIRCULATE
Circulates pool water;
bypasses filter.
R
E
C
IR
C
U
L
A
T
E
BA
CK
WAS
H
CL
OS
ED
W
IN
T
E
R
IZ
E
W
A
S
TE
FILTE
R
RIN
S
E
R
E
C
IR
C
U
L
A
T
E
BA
CK
WA
S
H
CL
O
S
E
D
W
IN
T
E
R
IZ
E
W
AS
TE
FILTER
R
IN
S
E
737 0294
BACKWASH
Reverses flow for
cleaning; water
goes through filter
to waste.
CLOSED
Shuts off all flow to
filter and pool.
WINTERIZE
Leaves all valve ports
partially open for
winter storage.
R
E
C
IR
C
U
L
A
T
E
B
AC
KW
AS
H
CL
O
S
E
D
W
IN
T
E
R
IZ
E
W
AS
TE
FILTER
R
IN
S
E
Valve Setting
Purpose/Flow
R
E
C
IR
C
U
L
A
T
E
B
AC
KW
AS
H
CL
OS
ED
W
IN
T
E
R
IZ
E
W
AS
TE
FILTER
R
IN
S
E
R
E
C
IR
C
U
L
A
T
E
BA
CK
WAS
H
CL
OS
ED
W
IN
T
E
R
IZ
E
W
AS
TE
FILTER
R
IN
S
E
738 0294
Figure 8
3/4 and 1 HP Models with
–A2 suffix use15-amp
straight outlet, above.
1-1/2 HP Models with
–2A2 suffix use 20-amp
straight outlet, above.
All models with –A1 or
–2A1 suffix use 20-amp
twist-lock outlet, above.
NOTICE:
Determine circuit breaker rating from Table III, above.
Determine correct outlet required from illustration below.
“ABG” and “JWP” 3/4 and 1 HP
Models with A2,
-2A2 and -A2U suffix and
1-1/2 HP Models with -2A4U
suffix use 15-amp straight
outlet, above.
“ABG” and “JWP” 1-1/2 HP
Models with A2,
-2A2 and A2U suffix use
20-amp straight outlet, above.
All “ABG” and “JWP” Models
with A2, -2A1 suffix use 20-amp
twist-lock outlet, above.