22
TA32W01 Thermostat
THERMOSTAT OPERATION
EMER
FAULT
STG1+2
Figure 6 – Thermostat display, buttons and switches
Figure 6 – Thermostat display, buttons and switches
Figure 6 – Thermostat display, buttons and switches
Figure 6 – Thermostat display, buttons and switches
Figure 6 – Thermostat display, buttons and switches
1
2
3
4
5
6
7
8
9
10
11
The Thermostat Buttons and Switches
Raises temperature setting
Lowers temperature setting.
FAN switch (
ON
,
AUTO
)
SYSTEM button (
COOL
,
AUTO
,
HEAT
,
EMER
,
OFF
)
The Display
Flame icon
( ) is displayed when the system is in
HEAT
mode.
Snowflake icon
( ) is displayed when
the system is in
COOL
mode.
Flame icon
( ) and
Snowflake icon
( ) are displayed simultaneously
when thermostat is in
AUTO
mode.
Displays “
BATT
” when the 2 “
AA
” batteries are low
and should be replaced. “
LO BATT
” is displayed
\when batteries are low with no system power.
Displays current temperature or “
LO
” when batteries
are low.
Displays currently programmed set temperature (this is blank when SYSTEM is
OFF
).
Displays “
FLTR
” when the system has run for the programmed filter time period as a reminder to change or clean
your filter.
Displays when in keypad lockout mode.
“
EMER
” is displayed flashing when the system is in
EMER
mode.
“
FAULT
” will be displayed when there is a malfunction in the heating/cooling system. It does not indicate a fault in the
thermostat.
Displays ( ) when limited (heat/cool) range is activated.
Displays ( ) flashing when an attempt is made to adjust temperature beyond the limited temperature range.
Stage 1 & 2
indicators: The thermostat shall indicate when the first and second stage is energized except in emer-
gency mode. The icon is “
STG 1
” for the first stage energized. The icons for the first and second stage energized are
“
STG 1+2
” located in the upper right side of the display.
1
2
3
4
5
5
8
11
13
12
14
7
9
6
7
10
13
12
14