24
TP32W01 Thermostat
THERMOSTAT OPERATION
17
16
15 14 13
12
11
10
9
8
7
6
5
4
3
2
1
The Thermostat Buttons
(Blue arrow) Lowers temperature setting (45°F or 7°C minimum)
(Red arrow) Raises temperature setting (99°F or 37°C maximum)
The multi-color indicator glows: green for 1st stage, yellow for 2nd stage, flashing yellow for 3rd stage, red for
emergency heat and flashing red for malfunction condition in system.
This button (on top of the cover) lights the display.
Used to initiate or review thermostat programming
or advance to next program period in programming
mode.
Used
with
TIME
/
TIME
to set the clock.
Used to adjust the time backward, or to select the
previous menu item.
Used to adjust the time forward, or to select the
next menu item.
Used
with
TIME
/
TIME
to set the
current
day.
Used to advance operation to the next program period or advance to the next day in programming mode.
Used to manually override programming to hold at a selected temperature.
Used to view ambient humidity or modify humidity setting.
Selects fan operation. This button is also used to program the fan to run continuously during a program period.
Used to enter the service menu to change or reset humidifier, air filter, UV bulb, and service timers.
Sets the system mode (
HEAT
ing,
EMER
gency (Heat Pump models only),
OFF
,
COOL
ing, or
AUTO
matic changeover).
Used to adjust the clock one hour forward or back.
Used to start or return to program operation.
FWD
BACK
FWD
BACK
1
2
3
4
5
6
7
8
9
10
12
13
14
15
16
17
11
PROGRAMMING
MANUAL OPERATION
(Bypassing the Program)
Your thermostat can be used to control temperature manually (without programming). For manual operation, press to
select
HEAT
or
COOL
, then press
PROGRAM
. Use or to set the temperature as desired.
SYSTEM
HOLD
.