INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT

IG1601EW   06/16

*IG1601EW* 

 

 

997-012330-14-R

Instruction Guide:

Color Touchscreen Communicating with Humidity Control Thermostat
TPCC32U01

Heat Pump Thermostat User Information

This communicating thermostat communicates via a 4-wire 
Modbus protocol and will only operate as a stand-alone 
thermostat with the Aurora Control System, or as a zone 
thermostat (not the MasterStat) in the IntelliZone2 or IntelliZone2 

 24V zoning system. The thermostat will auto recognize 

whether it is connected as a stand-alone thermostat or a zone 
thermostat and display the proper set up screens.

Zone Configuration

The thermostat will auto detect that it is attached to the 
IntelliZone2 relay panel and will display the screen below. Use 
the up/down arrows 

▲▼

 to select the zone.

If more than one zone is assigned the same zone number an 
error will be displayed on the thermostat and MasterStat. After 
the initial configuration to change the zone numbers enter the 
configuration mode by holding a finger over the Zone number 
in the upper left hand corner for 5 sec. Select zone number and 
use the up/down arrow to adjust.

Thermostat Operation

Adjusting Temperature

(Temporary Override in Programmable models)

* Displayed if configured as a Zone Thermostat
**Comp SPD and Room Humidity only displayed if configured as a 
stand-alone thermostat

Heating Set 

Point

Time

Date

Outside 

Temperature

(If installed)

Room Humidity**

Mode & 

Comp SPD**

Fan Operation

Error Code (If present)

Cooling 

Set Point

Room 

Temperature

Zone*

NOTE:

 Outdoor temperature is only displayed if an outdoor 

sensor is installed.  

1.  To select a MODE, press the screen button MODE, and 

then press the desired operating mode.

2.  Press the blue up or down arrow to increase or decrease the 

cooling temperature set point. Press the red up or down arrow 
to increase or decrease the heating temperature set point. 

Non-Critical Faults

Non-critical faults (error codes) are displayed below the 
temperature on the main screen.  These faults will clear 
themselves if the fault condition corrects itself. Your dealer 
should be informed when either a critical or non-critical fault 
occurs.

Lockout/Critical Faults

Critical faults will change the top and bottom bars of the screen 
red to indicate service needed. The system can be reset by 
pressing reset lockout.  Some of the faults will clear themselves 
if the fault condition corrects itself. Your dealer should be 
informed when either a critical or non-critical fault occurs.

Menu 

(Screens shown below are for stand-alone thermostat configuration)

Press the Menu button. 

Color Touchscreen Communicating with Humidity Control

TPCC32U01 (Firmware Version 3.01 and later)

Summary of Contents for TPCC32U01

Page 1: ...els Displayed if configured as a Zone Thermostat Comp SPD and Room Humidity only displayed if configured as a stand alone thermostat Heating Set Point Time Date Outside Temperature If installed Room Humidity Mode Comp SPD Fan Operation Error Code If present Cooling Set Point Room Temperature Zone NOTE Outdoor temperature is only displayed if an outdoor sensor is installed 1 To select a MODE press ...

Page 2: ... energized Ranges are OFF to 20 minutes in 5 minute increments Then adjust the time of the fan is OFF Ranges are 5 40 minutes in 5 minute increments Fan ON and OFF cycles will continue until the fan has been energized by a call for heating or cooling Humidity NOTE This option is not available if configured as a Zone Thermostat but is available at the MasterStat The humidity function must be enable...

Page 3: ...ttings Set Date and Time NOTE This option is not available if configured as a Zone Thermostat but is available at the MasterStat NOTE If this thermostat is installed with an AWL and Time Synchronization is enabled then Date and Time will be updated via the internet and cannot be manually adjusted If AWL Time Synchronization is disabled or no AWL is installed then follow the steps below for setting...

Page 4: ... CANCEL button 3 Press the OK to return to the previous menu USB This screen allows you to import or export the User setting or Program Superboost Variable Speed Heat Pumps Only NOTE This option is not available if configured as a Zone Thermostat but is available at the MasterStat Superboost can be found under the main menu settings of the thermostat The Superboost option temporarily enables a lar...

Page 5: ...bled Installer Information Advanced Features Safety Considerations Improper wiring or installation may damage thermostat Wiring must conform to local and national electrical codes Introduction The thermostat is a wall mounted low voltage thermostat which maintains room temperature by controlling the operation of a heating and air conditioning system Batteries are not required temperature and mode ...

Page 6: ...4VAC Hot DX Communication ABC Controller Thermostat Connection DX Communication TPCC32U01 Color Touchscreen Thermostat Thermostat Connections C 24V Common for Control Circuit R 24V Supply for Control Circuit DX Communication Terminal DX Communication Terminal S1 S2 Remote Temperature Sensor indoor or outdoor WARNING Before installing thermostat turn off all power to unit There may be more than one...

Page 7: ... operates in the HEAT mode and DEHUMIDIFY operates in COOL mode NONE Neither is active Restart The Restart button is used to load firmware updates and give the capability to reboot the thermostat without cycling power to the heat pump Installer Setting Page Two Press NEXT button It will bring you to the second page of installer setting Cycles Per Hour NOTE This option is not available on variable ...

Page 8: ... terminals Compressor Satisfy NOTE This option is not available if configured as a Zone Thermostat Normal allows compressor downstaging from Y2 to Y1 Recommended setting for most products Y2 Finish Once the heat pump has engaged Y2 the thermostat will not allow downstaging to Y1 The call is satisfied in Y2 Option not available on variable speed systems Installer Setting Page Three Press NEXT butto...

Page 9: ...one Thermostat but is available at the MasterStat This screen changes the unit of measurement that is displayed on the thermostat Fahrenheit is the default setting Installer Setting Page Four Press NEXT button It will bring you to the Installer Setting page four Residential Commercial For future use Energy Demo Mode NOTE This option is not available if configured as a Zone Thermostat but is availa...

Page 10: ...igure Aurora System screen Yes Yes No Install communicating thermostat Do you have an AID tool No Get an AID tool Yes Which of these do you have TST ABC AXB IZ2 AOC MOC EEV Wire non communicating 8 wire thermostat to P1 terminal on the ABC board Is the thermostat communicating Yes No Issue resoled Variable Speed unit Single and Dual Capacity unit Y Active Communication N Device has been found but ...

Page 11: ...ride and the TST removed from the Configure Aurora System screen No Yes Yes Replace the ABC board Replace the thermostat DX R C DX 1 2 3 4 C R Can you send a picture of the ABC P7 connector and thermostat wiring connections Review and confirm the thermostat is wired correctly Check the continuity of the thermostat wires by removing wires from the green plug at ABC P7 and wire tying wires 1 and 2 t...

Page 12: ...01EW 06 16 IG1601EW 997 012330 14 R NOTES 2016 WaterFurnace International Inc 9000 Conservation Way Fort Wayne IN 46809 9794 WaterFurnace has a policy of continual product research and development and reserves the right to change design and specifications without notice ...

Reviews: