background image

4

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT

IG1601EW   06/16

*IG1601EW* 

 

 

997-012330-14-R

Sound Volume 

Adjust the desired sound level of screen buttons when pressed 
and the desired sound, either beep, one click, or two clicks.

Background

Select the desired background. 

Picture Upload 

This thermostat will allow personal photo upload to be displayed 
once the thermostat goes into sleep mode. The thermostat 
can only accept photos that are tci format. Common photo 
formats can be converted to the tci format, which is used by the 
thermostat, by using the thermostat photo converter software. 
Once the photos have been converted and uploaded to the 
thermostat they will be displayed as a slide show when the 
thermostat goes into sleep mode. Sleep mode occurs after 5 
minutes of inactivity (no screen touches). The photo conversion 
software and instructions for uploading the photos can be found 
at www.auroracontrols.com

Vacation

(NOTE: This option is not available if configured as a Zone 
Thermostat, but is available at the MasterStat.)

1. 

From the MENU, press the Vacation button to set vacation 
starting date, time, and desired temperature, return date, time.

2. 

To cancel this setting, press the CANCEL button.

3. 

Press the OK to return to the previous menu.

USB 

This screen allows you to import or export the User setting or 
Program.

Superboost (Variable Speed Heat Pumps Only)

(NOTE: This option is not available if configured as a Zone 
Thermostat, but is available at the MasterStat.)

Superboost can be found under the main menu settings of 
the thermostat. The Superboost option temporarily enables 
a larger cooling capacity range, for example, a large party. 
Normal cooling mode is limited to compressor speeds 1-9 and 
Superboost allows compressor speeds 10-12 if needed. This 
screen will allow the homeowner to turn on or off the Superboost 
option. The Superboost option will be enabled, by default, for a 
24-hour period of time and then will automatically be disabled. 

CAUTION

: Continuous use of Superboost will result in 

the overheating of the ground loop.

On Peak 

(NOTE: This option is not available if configured as a Zone 
Thermostat, but is available at the MasterStat.)

This screen allows you to adjust the desired On Peak 
temperature.

Energy Monitor (If Installed)

(NOTE: This option is not available if configured as a Zone 
Thermostat, but is available at the MasterStat.)

1. 

If your heat pump has Energy Monitoring installed, the energy 
consumed can be viewed by pressing the Energy button.

2. 

There are three choices to view the energy consumed: 
Instant, Daily, and Monthly.

Instantaneous Energy Use screen

Summary of Contents for TPCC32U01

Page 1: ...els Displayed if configured as a Zone Thermostat Comp SPD and Room Humidity only displayed if configured as a stand alone thermostat Heating Set Point Time Date Outside Temperature If installed Room Humidity Mode Comp SPD Fan Operation Error Code If present Cooling Set Point Room Temperature Zone NOTE Outdoor temperature is only displayed if an outdoor sensor is installed 1 To select a MODE press ...

Page 2: ... energized Ranges are OFF to 20 minutes in 5 minute increments Then adjust the time of the fan is OFF Ranges are 5 40 minutes in 5 minute increments Fan ON and OFF cycles will continue until the fan has been energized by a call for heating or cooling Humidity NOTE This option is not available if configured as a Zone Thermostat but is available at the MasterStat The humidity function must be enable...

Page 3: ...ttings Set Date and Time NOTE This option is not available if configured as a Zone Thermostat but is available at the MasterStat NOTE If this thermostat is installed with an AWL and Time Synchronization is enabled then Date and Time will be updated via the internet and cannot be manually adjusted If AWL Time Synchronization is disabled or no AWL is installed then follow the steps below for setting...

Page 4: ... CANCEL button 3 Press the OK to return to the previous menu USB This screen allows you to import or export the User setting or Program Superboost Variable Speed Heat Pumps Only NOTE This option is not available if configured as a Zone Thermostat but is available at the MasterStat Superboost can be found under the main menu settings of the thermostat The Superboost option temporarily enables a lar...

Page 5: ...bled Installer Information Advanced Features Safety Considerations Improper wiring or installation may damage thermostat Wiring must conform to local and national electrical codes Introduction The thermostat is a wall mounted low voltage thermostat which maintains room temperature by controlling the operation of a heating and air conditioning system Batteries are not required temperature and mode ...

Page 6: ...4VAC Hot DX Communication ABC Controller Thermostat Connection DX Communication TPCC32U01 Color Touchscreen Thermostat Thermostat Connections C 24V Common for Control Circuit R 24V Supply for Control Circuit DX Communication Terminal DX Communication Terminal S1 S2 Remote Temperature Sensor indoor or outdoor WARNING Before installing thermostat turn off all power to unit There may be more than one...

Page 7: ... operates in the HEAT mode and DEHUMIDIFY operates in COOL mode NONE Neither is active Restart The Restart button is used to load firmware updates and give the capability to reboot the thermostat without cycling power to the heat pump Installer Setting Page Two Press NEXT button It will bring you to the second page of installer setting Cycles Per Hour NOTE This option is not available on variable ...

Page 8: ... terminals Compressor Satisfy NOTE This option is not available if configured as a Zone Thermostat Normal allows compressor downstaging from Y2 to Y1 Recommended setting for most products Y2 Finish Once the heat pump has engaged Y2 the thermostat will not allow downstaging to Y1 The call is satisfied in Y2 Option not available on variable speed systems Installer Setting Page Three Press NEXT butto...

Page 9: ...one Thermostat but is available at the MasterStat This screen changes the unit of measurement that is displayed on the thermostat Fahrenheit is the default setting Installer Setting Page Four Press NEXT button It will bring you to the Installer Setting page four Residential Commercial For future use Energy Demo Mode NOTE This option is not available if configured as a Zone Thermostat but is availa...

Page 10: ...igure Aurora System screen Yes Yes No Install communicating thermostat Do you have an AID tool No Get an AID tool Yes Which of these do you have TST ABC AXB IZ2 AOC MOC EEV Wire non communicating 8 wire thermostat to P1 terminal on the ABC board Is the thermostat communicating Yes No Issue resoled Variable Speed unit Single and Dual Capacity unit Y Active Communication N Device has been found but ...

Page 11: ...ride and the TST removed from the Configure Aurora System screen No Yes Yes Replace the ABC board Replace the thermostat DX R C DX 1 2 3 4 C R Can you send a picture of the ABC P7 connector and thermostat wiring connections Review and confirm the thermostat is wired correctly Check the continuity of the thermostat wires by removing wires from the green plug at ABC P7 and wire tying wires 1 and 2 t...

Page 12: ...01EW 06 16 IG1601EW 997 012330 14 R NOTES 2016 WaterFurnace International Inc 9000 Conservation Way Fort Wayne IN 46809 9794 WaterFurnace has a policy of continual product research and development and reserves the right to change design and specifications without notice ...

Reviews: