Control Operation During A Power Failure
In the event of a power failure, the valve will keep track of the time and day for 48 hours.
The programmed settings are stored in a non-volatile memory and will not be lost during a
power failure. If power fails while the unit is in regeneration, the valve will finish regenera-
tion from the point it is at once power is restored. If the valve misses a scheduled regen-
eration due to a power failure, it will queue a regeneration at the next regeneration time
once power is restored.
Main Display
About The System
Periodically the filter will require a back wash to clean the trapped particles and unpack the
filter bed to restore the system flow rates. The table below explains the regeneration steps.
Regeneration Process
Step
Name
Description
#1
Back
Wash
Fresh
water
is
introduced
to
the
bottom
of
the
tank
flowing
upwards
expanding
the
filter
media
to
rinse
out
any
dirt
or
small
particles
to
the
drain
and
to
un
‐
compact
the
bed
to
restore
full
service
flow
rates.
#2
Rinse
Fresh
water
is
introduced
from
the
top
of
the
tank
flowing
down
through
the
filter
bed
rinsing
any
unfiltered
water
to
the
drain.
The main display page will pause on the Date and Time page for 5 seconds. Then it will
continually scroll through all of the system diagnostic display pages. Depending on the
Valve Type some pages will not be displayed. To manually scroll through the diagnostics,
press the down or up key. To reset the TOTAL REGENS, TOTAL GALLONS OVER RUN TO-
TAL, or PEAK flow rates, press and hold the MENU until the value changes to zero.
PARAMETER
DESCRIPTION
JULY/17/2012
8:30
PM
TOTAL
1,500
GAL
REMAIN
1,200
GAL
LAST
REGEN
9/24/12
TOTAL
REGENS
10
TOTAL
GALLONS
001590
GAL
TOTAL
4
DAYS
REMAIN
3
DAYS
OVER
RUN
TOTAL
0000
GAL
CURRENT
1.5
GPM
PEAK
6.5
GPM
DELAYED
REGEN
OFF
REGEN
TIME
12:00
AM
VALVE
MODE
B.W.
FILTER
The
current
setting
for
regeneration
time.
The
current
setting
of
the
valve
mode.
The
total
number
of
regenerations.
The
total
amount
of
gallons
treated
by
the
system.
The
total
amount
of
water
that
has
exceeded
the
system
capacity
over
the
last
4
regenerations.
When
remaining
goes
to
zero,
the
gallons
used
will
be
added
to
over
run
total.
The
current
flow
rate
and
the
peak
flow
rate
since
the
last
regeneration.
Advises
whether
a
delayed
regeneration
has
been
scheduled
manually
or
automatically.
Month,
Day,
Year,
Time
The
number
of
days
remaining
before
regeneration.
This
option
is
only
in
filter
mode.
The
total
amount
is
the
system
capacity
when
fully
regenerated.
The
remaining
is
the
capacity
left
in
the
system.
The
date
of
the
last
regeneration.
12