PARTS LIST 

 

 

KEY 

DESCRIPTION 

PART NUMBER COMMENT KEY 

DESCRIPTION 

PART NUMBER COMMENT 

Filter housing 

HA1014WW-C 

 

10 

Post carbon filter 

AIC10EZ 

 

Cartridge 5 mic sediment 

PP1005 

 

11 

Check valve 

A4CV4 

 

 

Cartridge, Carbon 

CBC5CTO3 

 

12 

4-way shutoff valve 

ROS002 

 

Mounting bracket 

RO4053M 

 

13 

RO storage tank 

ROT32P 

 

4  Male elbow, push-on, 1/4" 

A4ME4 

 

14 

Plastic wrench 

HAN-01W 

 

Mounting clips 

WP25 

 

15 

Faucet 

WDF103LBTAQ 

 

Elbow, push-on, ¼’’ 

A4EU4 

 

16  Tank valve, push-on, 1/4" 

EA3931 

 

Encapsulated membrane  BME1812RE75 

 

17 

PE tube - 1/4" 

3634100 

clear 

Mounting clips 

WP225 

 

18 

Drain saddle 

WP-14EZ 

 

Tee, push-on, ¼’’ 

EZT141414DT 

 

19 

Water supply adapter 

H0630426 

 

Summary of Contents for Vectapure NX

Page 1: ...IPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PROD...

Page 2: ...m the water molecules The final stage is an in line carbon filter that eliminates all remaining traces of taste and odour that the water may have absorbed from the holding tank or the plumbing system...

Page 3: ...NX system uses premium quality TFC Thin Film Composite membranes specially chosen for household applications 4 TDS The higher the Total Dissolved Solids in the raw water the lower the output of produ...

Page 4: ...ay install a tube tee on the line to the faucet to connect icemakers or other faucets to the system If you locate your system farther than 20 feet from the faucet you will need to use 3 8 tubing or in...

Page 5: ...the sink If it has an existing hole for mounting a faucet skip to Step 4 6 2 Locate and mark the spot you wish to install the faucet Make sure it does not interfere with operation of the main faucet...

Page 6: ...T THIS TIME Spin the filter housing bowls on to the RO unit and hand tighten Step 8 Connect the System Tubing READ THIS SECTION CAREFULLY MOST SYSTEM LEAKS ARE CAUSED FROM IMPROPERLY COMPLETED PUSH ON...

Page 7: ...any joints if necessary 2 If a booster pump kit was installed insert the plug into a standard wall receptacle System pump will switch on and begin to operate 3 Let the system operate for about 10 minu...

Page 8: ...y to load the new cartridges 6 To load the cartridges repeat Step 9 from the installation instructions above Replace the post carbon filter by disconnecting the both Tee fitting and faucet tube from t...

Page 9: ...lve closed or tank valve closed Open valves Low water pressure Install booster pump Crimped poly tube Repair or replace tube Raw water TDS high Consult dealer may need pre treatment Filters or membran...

Page 10: ...4CV4 Cartridge Carbon CBC5CTO3 12 4 way shutoff valve ROS002 3 Mounting bracket RO4053M 13 RO storage tank ROT32P 4 Male elbow push on 1 4 A4ME4 14 Plastic wrench HAN 01W 5 Mounting clips WP25 15 Fauc...

Page 11: ...10 VECTAPURE NX RESIDENTIAL REVERSE OSMOSIS SYSTEM FLOW LAYOUT...

Page 12: ...OGIES WEBSITE FOR INFORMATION CONSUMER ONLINE REPLACEMENT PARTS AND PRODUCT UPDATES AT www waterite com Waterite Technologies Inc 3 75 Meridian Drive Winnipeg Manitoba Canada R2R 2V9 204 786 1604 204...