Step 5. Install the Drain Saddle Assembly 

1. 

Select the location to install the drain saddle assembly.  This is usually on the sink drainpipe and needs to 
always be located above the “S” trap. 

 
2. 

Position the drain saddle assembly in the selected location and mark the spot through the threaded outlet 
with a pencil or marker 

 

3. 

Drill a ¼” hole at the marked spot.  Strip the backing paper from the adhesive side of the saddle gasket and 
position on the inside of the drain saddle, aligning the hole with the threaded outlet.  Attach the drain saddle 
to the drainpipe, aligning the push-on port with the drilled hole.  Tighten the clamp snugly. DO NOT OVER 
TIGHTEN. 

 

4. 

The black drain tube may be inserted directly into the push-on drain port, using instructions in Step 8. below.  
Do not attach poly tube at this time. 

 

Step 6. Install the Tank Valve, Preparing the Storage Tank 

1. 

Wrap the threaded storage tank nipple with two wraps of Teflon tape.  Thread on tank shut- off valve until 
snug.  Using the wrench, turn an additional ¼ turn.  DO NOT OVER TIGHTEN.   Open tank valve to the fully 
open position. 

 

Step 7. Mounting the RO Unit  

1. 

While holding the RO unit in its mounting position, mark the holes for the wall screws.  Using a 1/8” bit, drill 
the pilot holes for the screws.  Screw in the mounting screws leaving ¼” protruding.  Hang the RO mounting 
bracket on the screws and tighten. 

 
2. 

 If the unit is to be mounted on wallboard, use plastic screw anchors, available at any builder’s supply and 
follow the manufacturer’s directions. 

 

3. 

DO NOT INSTALL FILTER CARTRIDGES AT THIS TIME.  

Spin the filter housing bowls on to the RO unit 

and hand-tighten. 

 
Step 8. Connect the System Tubing  
 

READ THIS SECTION CAREFULLY. MOST SYSTEM LEAKS ARE CAUSED FROM 

IMPROPERLY COMPLETED PUSH-ON JOINTS. 

Making and securing a push on connection is simple.  First, the tubing should be cut 
square and any burrs or rough edges removed.  Insert the tube firmly and push until 
the tube end contacts the stop.  Gently tug the tube backwards to assure a secure 
connection.  To disconnect, pull the tube while pushing in the collet ring.  The joint 
may be used over and over again, if necessary. 

 

 

1. 

Connect the cold water supply valve to the first filter housing water inlet push-on fitting (marked “water 
inlet”), after cutting the ¼” clear tube to the length required.  

 

 

2. 

Connect the black ¼” tube (marked “to drain”) to the Drain Saddle push-on connection (your black drain 
tube is pre-attached to your RO).  Please note that the drain line flow restrictor has been installed INSIDE 
the black drain tube at the waste elbow, on the membrane housing.  Place the storage tank in the location 
you have chosen for it.  Using the clear ¼” tube connect the system fitting marked “to tank” to the tank valve.  
Connect the ¼” tube attached to the faucet to the system fitting marked “to faucet”.  If the tubing is not pre-
attached to the faucet, cut the 3/8” clear tubing to the desired length and attach the tube to the fitting at the 
base of the faucet shank to the fitting marked “ to faucet” on the RO unit. 

 

3. 

You may find that your unit does not have labels attached to indicate the water line and drain line 
connections.  The photos below are labelled with the correct locations for the water and drain connections.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

     

 
 

 

 

 

 

 

  

 

            

 
 

                                       Top View 

 

 

 

                 Back View 

 
 

To drain 

To faucet 

Raw water inlet 

To storage tank 

Summary of Contents for Vectapure NX

Page 1: ...IPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PROD...

Page 2: ...m the water molecules The final stage is an in line carbon filter that eliminates all remaining traces of taste and odour that the water may have absorbed from the holding tank or the plumbing system...

Page 3: ...NX system uses premium quality TFC Thin Film Composite membranes specially chosen for household applications 4 TDS The higher the Total Dissolved Solids in the raw water the lower the output of produ...

Page 4: ...ay install a tube tee on the line to the faucet to connect icemakers or other faucets to the system If you locate your system farther than 20 feet from the faucet you will need to use 3 8 tubing or in...

Page 5: ...the sink If it has an existing hole for mounting a faucet skip to Step 4 6 2 Locate and mark the spot you wish to install the faucet Make sure it does not interfere with operation of the main faucet...

Page 6: ...T THIS TIME Spin the filter housing bowls on to the RO unit and hand tighten Step 8 Connect the System Tubing READ THIS SECTION CAREFULLY MOST SYSTEM LEAKS ARE CAUSED FROM IMPROPERLY COMPLETED PUSH ON...

Page 7: ...any joints if necessary 2 If a booster pump kit was installed insert the plug into a standard wall receptacle System pump will switch on and begin to operate 3 Let the system operate for about 10 minu...

Page 8: ...y to load the new cartridges 6 To load the cartridges repeat Step 9 from the installation instructions above Replace the post carbon filter by disconnecting the both Tee fitting and faucet tube from t...

Page 9: ...lve closed or tank valve closed Open valves Low water pressure Install booster pump Crimped poly tube Repair or replace tube Raw water TDS high Consult dealer may need pre treatment Filters or membran...

Page 10: ...4CV4 Cartridge Carbon CBC5CTO3 12 4 way shutoff valve ROS002 3 Mounting bracket RO4053M 13 RO storage tank ROT32P 4 Male elbow push on 1 4 A4ME4 14 Plastic wrench HAN 01W 5 Mounting clips WP25 15 Fauc...

Page 11: ...10 VECTAPURE NX RESIDENTIAL REVERSE OSMOSIS SYSTEM FLOW LAYOUT...

Page 12: ...OGIES WEBSITE FOR INFORMATION CONSUMER ONLINE REPLACEMENT PARTS AND PRODUCT UPDATES AT www waterite com Waterite Technologies Inc 3 75 Meridian Drive Winnipeg Manitoba Canada R2R 2V9 204 786 1604 204...

Reviews: