Section 4: Troubleshooting Guide 

 

 
Trouble Shooting Guide   

Possible Cause 

 

 Solution 

 
Low Water or No Water   

Water supply valve closed 

 

 

 

or tank valve closed. 

 

Open valves 

 

Low water pressure 

 

Install booster pump 

Crimped poly tube 

 

Repair or replace tube 

Raw water TDS high 

Consult dealer – may need pre-
treatment 

Filters or membranes plugged 

Replace filters 

Tubes installed to wrong fitting 

Install tubes per S.8 (1), (2) and (3). 
 

Leaking Joints

 

Fittings not seated 

 

Disconnect fitting and reseat tube 

Filter housing leaking

 

 

 

Tighten with housing wrench 

 

 

 

Inspect o-rings for cuts or crimps 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Vectapure NX

Page 1: ...IPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PROD...

Page 2: ...m the water molecules The final stage is an in line carbon filter that eliminates all remaining traces of taste and odour that the water may have absorbed from the holding tank or the plumbing system...

Page 3: ...NX system uses premium quality TFC Thin Film Composite membranes specially chosen for household applications 4 TDS The higher the Total Dissolved Solids in the raw water the lower the output of produ...

Page 4: ...ay install a tube tee on the line to the faucet to connect icemakers or other faucets to the system If you locate your system farther than 20 feet from the faucet you will need to use 3 8 tubing or in...

Page 5: ...the sink If it has an existing hole for mounting a faucet skip to Step 4 6 2 Locate and mark the spot you wish to install the faucet Make sure it does not interfere with operation of the main faucet...

Page 6: ...T THIS TIME Spin the filter housing bowls on to the RO unit and hand tighten Step 8 Connect the System Tubing READ THIS SECTION CAREFULLY MOST SYSTEM LEAKS ARE CAUSED FROM IMPROPERLY COMPLETED PUSH ON...

Page 7: ...any joints if necessary 2 If a booster pump kit was installed insert the plug into a standard wall receptacle System pump will switch on and begin to operate 3 Let the system operate for about 10 minu...

Page 8: ...y to load the new cartridges 6 To load the cartridges repeat Step 9 from the installation instructions above Replace the post carbon filter by disconnecting the both Tee fitting and faucet tube from t...

Page 9: ...lve closed or tank valve closed Open valves Low water pressure Install booster pump Crimped poly tube Repair or replace tube Raw water TDS high Consult dealer may need pre treatment Filters or membran...

Page 10: ...4CV4 Cartridge Carbon CBC5CTO3 12 4 way shutoff valve ROS002 3 Mounting bracket RO4053M 13 RO storage tank ROT32P 4 Male elbow push on 1 4 A4ME4 14 Plastic wrench HAN 01W 5 Mounting clips WP25 15 Fauc...

Page 11: ...10 VECTAPURE NX RESIDENTIAL REVERSE OSMOSIS SYSTEM FLOW LAYOUT...

Page 12: ...OGIES WEBSITE FOR INFORMATION CONSUMER ONLINE REPLACEMENT PARTS AND PRODUCT UPDATES AT www waterite com Waterite Technologies Inc 3 75 Meridian Drive Winnipeg Manitoba Canada R2R 2V9 204 786 1604 204...

Reviews: