Installation and connection
05.06.2015
18 / 80
Copyright
2013 by: WATERKOTTE GmbH. Subject to changes.
6.2
Environmental conditions for installation
Note the minimum volume of the installation room and consider the type of
the refrigerant (EN 378-1).
The room must be dry. Room temperature should be b5 °C and
+25 °C. To facilitate maintenance, the use of a base plate is recommended.
To compensate for minor unevenness, we recommend use of an approx.
10 mm thick rubber mat.
6.2.1
Installation of the heat pump
Transport the EcoTouch Ai1Air to installation site. Align the heat pump unit
in a horizontal position.
To do this, use the set screws for height adjustment (under the corners of
the unit), width across flats 30 mm
.
6.2.2
Preparation of the assembly
After completion of assembly the supply lines have to be accessible.
Arrange them as follows:
Place the connecting tubes of the tank at the side of the unit (right).
Figure 4
: Arrangement of connecting tubes before installation