Installation and connection of outdoor unit
05.06.2015
33 / 80
Copyright
2013 by: WATERKOTTE GmbH. Subject to changes.
8.2.2
Connections indoor unit (refrigerant line)
The connections are located on the rear of the indoor unit.
Connection dimensions:
16 x 1 mm or 12.7 x 1 mm* Cu
pipe
, gas side
10 x 1 mm or 6.35 x 1 mm* Cu
pipe
, liquid side
* Heat pump series EcoTouch Ai1 Air Power Inverter 5004.5 /
5006.5. are connected with copper tube 12,7 x 1 mm (fluid site) and
6,35 x 1 mm (liquid site). Adapter pieces according to the heat pumps
are adjusted.
8.2.3
Connections outdoor unit (refrigerant line)
Remove service panel:
Loosen 3 screws, push service panel down and remove.
Remove front and rear line cover (2 screws each).
The connections are located in front of outdoor unit, behind the service