Safety measures
12.11.2015
48 / 60
Z21826
Copyright
2013 by: WATERKOTTE GmbH. Subject to changes
14
Safety measures
14.1
Pressure limits of compressor
The cooling circuit is protected against unacceptable excessive pressure by a
type-tested pressostat. The switch interrupts the control voltage of the compres-
sor contactor. Restart is locked by the central control unit and must be manually
reset. Manipulation of safety switches is prohibited and is a violation of UVV
VBG20 (accident prevention regulations for cooling devices). In any case, it will re-
sult in exclusion of warranty.
The high pressure pressostat is placed in the pipe of the refrigerant medium at the
exit of the condenser.
Shift points (R410A):
45.0 bar OFF --- 35.0 bar ON
14.2
Motor protection against excessive temerpature
Fully hermetic compressors are equipped with a bimetal switch that disconnects
the power supply and connects again after cool down to protect against exces-
sive motor temperatures; an error message is not generated.
14.3
Refrigerator oil
Use only the specified oil type (e
ster oil ICI Emkarate RL 32-3MAF)
; non-
compliance will result in exclusion of warranty and certainly cause malfunctions.
Improper manipulation to the refrigeration cycle leads to total loss and the loss of
warranty. Any work on the hydraulic circuit of the heat pump shall only be per-
formed by skilled workers!
Summary of Contents for EcoTouch Ai1 Geo
Page 57: ...Technical data 12 11 2015 57 60 Z21826 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 58: ...Technical data 12 11 2015 58 60 Z21826 Copyright 2013 by WATERKOTTE GmbH Subject to changes...
Page 59: ...Technical data 12 11 2015 59 60 Z21826 Copyright 2013 by WATERKOTTE GmbH Subject to changes...