BLUPURA
Fizz 80
Manual
Page 21 ‐ Revision: 11‐2‐2018
ELECTRICAL CONNECTION:
NOTE:
Recommended to plug system into GFI‐Protected outlet. Be careful to not overload branch
electrical supply.
5.
Connect the power cable to a socket.
6.
Turn on Power switch on at back of unit.
I = ON
. The ice‐bank pump,
compressor and fan are now activated.
7.
Pull Sparkling Dispense Tap to release air in the circuit and allow the pump to fill the
carbonator with water. After approximately 1‐2 minutes, the sparkling pump stops.
SANITIZATION OF DRINKING CIRCUIT:
The sanitization of the drinking water circuit has to be performed:
Every time the
BLUPURA Fizz 80
is installed
Every 6 months of operation
Each Change of filters
After system has been inoperative of 5 days or more.
8.
Turn off incoming feed water (if connected).
9.
Remove Filter Cartridge (if connected).
10.
Mix ½ gallon of sanitizer per directions or use Bleach Solution (1 teaspoon = 1/6 oz. = 5 ml = ½
cap full) of household bleach (Sodium Hypochlorite 5 ‐ 10% Concentration) with 1/2 gallon of
water. Always ensure sanitizer is compatible with stainless steel and acetyl plastic.
11.
Open the water entering the machine and take approximately 5 liters of still water and 5 liters
of sparkling water.
12.
Keep the sanitizing solution in circuit for 20 minutes.
13.
Install new filter cartridge.
14.
Take 10 liters of still water and 10 liters of sparkling water to rinse the circuit.
WARNING!
SANITIZER MAY CONTAIN HAZARDOUS CHEMICALS.
Use of proper personal
protective equipment such as rubber gloves and eye protection is required.