WARNING! 

TIP HAZARD. 

Dispenser could tip or fall causing serious injury. Always install unit on a 

firm, flat, and level surface and secure the 

WL3 FW Water Treatment System 

to the base cabinet with 

the screw provided to lock the components together. Secure unit to cabinet, wall, or floor if needed.

 

Never place heavy items on top of unit and never climb, stand, or hang on unit or storage cabinet to 
prevent injury and damage.

 

  

WARNING! 

UNIT IS HEAVY. TWO PERSON LIFT REQUIRED. 

Transport unit empty and always use 

material handling equipment or two people with proper lifting technique to reduce injury risk.

 

 

WARNING!  

STORE AND TRANSPORT UNIT EMPTY.   ALWAYS SANITIZE BEFORE USE.

 

The unit must be completely drained and sealed before storing to avoid stagnation and reduce 
microbiological contamination (potential bacterial growth). Sanitize before use to eliminate any 
potential microbiological contaminates

 

  

CAUTION! 

INDOOR USE ONLY. 

Intended for household use only.  Never expose to direct sunlight, 

heat sources, or ambient air temperature above 32°C (90°F) or below 2°C (35°F). Install indoors and 
keep unit away from humidity levels above 65%. Never expose to freezing temperatures. Ensure there is 
adequate clearance around the unit to allow refrigeration system condenser to dissipate heat. Warmer 
environments require more clearance around the unit. Minimum clearance around all surfaces of the 
machine is 50mm. Installs where the ambient temperature exceeds 25°C, require a minimum of 100mm 
clearance for proper heat dissipation and efficient operation.

 

 

CAUTION! 

USE A WATER PRESSURE REGULATOR. 

Waterlogic will not be responsible for injury or 

damage caused by excessive water pressure. Input or feed pressure must be 2.5 bar (36 psi) to 3.5 bar 
(51 psi). Be aware of any potential pressure surges caused by building/municipal pumping stations. 
Water block devices and external leak detectors are strongly recommended. Locate the unit as close to 
the water supply and the electrical connections as possible to minimize risk.

 

 

CAUTION! 

USE PROPER SUPPLY LINES AND FEED WITH POTABLE AMBIENT WATER ONLY.

 

Feed water over 32°C (90°F) may damage the treatment components. Always use supply lines with 
adequate pressure rating and UV resistance. Close water supply valve and contact service 
representative if a leak is noticed.

 

Contact Waterlogic for assistance or help finding an Authorized Service Representative.

 

Summary of Contents for CU324

Page 1: ...imited Second Floor Suite 4 Beacon Court Sandyford Co Dublin Ireland Tel 353 0 1293 1960 Fax 353 0 1293 1052 For Technical Support Email support waterlogicsupport zendesk com WLI UK LTD Global Headqua...

Page 2: ...se by these qualified individuals Waterlogic encourages users to learn about products however we believe that product knowledge and service is best obtained by consulting Waterlogic or an Authorized W...

Page 3: ...ONTENTS Safety Alert Symbols 4 Safety Precautions 4 Features and Benefits 6 Firewall Purification System 7 Certifications 8 Model Designations and General Specifications 9 Electrical and Shipping Spec...

Page 4: ...t against electrical shock and exposure to UVradiation DANGER ELECTRICAL SHOCK HAZARD Always use a dedicated and properly earthed outlet Unit should be protected by ground fault circuit interrupter GF...

Page 5: ...roper management and transportation of the machine to avoid damaging the refrigerant fluid and causing a dangerous leak Discarded appliance should be isolated from fire sources and cannot be burned Pl...

Page 6: ...l indoors and keep unit away from humidity levels above 65 Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate...

Page 7: ...its the growth of microorganisms providing additional surface protection Large Dispense Area with Recessed Sanitary Faucet Increased dispense height to accommodate large vessels Intuitive recessed dis...

Page 8: ...FIREWALL PURIFICATION SYSTEM Our breakthrough Firewall technology delivers 99 9999 bacteria free water right at the point of dispense Firewall delivers the safest water possible through a sanitary fa...

Page 9: ...s certified by IAPMO R T according to NSF ANSI 42 NSF ANSI 53 NSF ANSI 55 Class A NSF ANSI P231 US EPA Guide Standard and Protocol for Testing Microbiological Water Purifiers for the reduction of the...

Page 10: ...er Output 95 C 203 F Factory Set Point Output Flow 1 6Lpm Firewall Purification Rating Input Connections Quick Connect Bulkhead for Potable Water Recommended Water Feed 2 7 3 5 Bar 40 51 psi Always Us...

Page 11: ...100 W 1 2 A Controls 25 W 0 1 A Firewall UV System 13 W 0 2 A Pump Sparkling 12 W 0 1 A WL3FW TOTAL 950 W 5 6 A WL3 FW SHIPPING SPECIFICATIONS ITEM WL3 FW FS Tower Width Depth Height Box is 470 mm x...

Page 12: ...dispense limit TO DISPENSE SPARKLING WATER Select Sparkling dispense icon lower until it lights Hold until desired amount is dispensed Release to stop dispense There will be a 2 second initial delay...

Page 13: ...imicrobial Surface Protection WL3FW features a modern look with advanced touch action dispensing equipped with back lights to improve user experience Intelligent dispensing limits continuous dispense...

Reviews: