Ecostream
Manual
Page 16 - Revision: 11-13-2020
RESETTING THE HOT TANK OVERLOAD OR HIGH LIMIT SAFETY
1.
Red Heater and Compressor Switch must be in the OFF position
O=OFF
2.
Unplug the Power Cord from rear of
ECOSTREAM
Water Treatment System.
3.
Tower Model: Remove the Lower Front Panel by removing the Phillips Head Screws
underneath the Lower Front Panel.
Counter Top Model: Remove the Side Panel by removing Phillips Head Screws from Side
Panel.
4.
Locate the protective metal box on the rear of the Hot Tank.
As you look through the condenser coils on the rear of the unit,
you will see the Hot Tank located on the right-hand side.
5.
Reach up behind the Hot Tank and take hold of the Protective
Metal Box covering the Thermostat and Overload on the Hot Tank.
There are nuts that secure the metal box to the Hot Tank.
However, the nuts are loose enough to allow you to remove the
metal box.
If the nuts on the metal box are too tight, loosen the nuts securing
the Hot Tank to the upper base of the unit and lower the hot tank
so you can remove the metal box.
For demonstrative purposes, photos below have lowered the Hot
Tank from the unit
.