background image

 

P2 Classe

 Manual 

                                                      Page 14 – Revision: 3-2-2021 

REPLACEMENT COMPONENTS (CONSUMABLES) 

 

Component 

WLCP Part 

No. 

Frequency of Replacement 

UV Bulb, 15 Watts Assembly  

12-2350 

Every 12 months, or as required CT-2030-I00-

00 

 

CAUTION!  

Use only Waterlogic Replacement parts that can be obtained from 

Waterlogic

 

or an 

Authorized Waterlogic Dealer

, failure to do so will void the Warranty. 

 

See Installation and Service Manual for additional information. 

 

 

Surface Cleaning  

Clean on a regular basis with damp lint free cloth.  Never use harsh chemicals (alcohol or acid 

based) or abrasive agents on any part of the product to avoid damage.  A mild cleaner such as 

Simple Green or equivalent is recommended.   

 

 

DISPOSAL 

End of Life 

At the 

end of this product’s life

, ensure that it is disposed of in an environmentally friendly 

manner which is fully compliant 

with all Federal/State/Local Requirements and Guidelines

.  

Do not dispose of this appliance with normal household or business waste.  

Summary of Contents for P2 Classe

Page 1: ...s Pro Drive Grapevine TX 76051 800 288 1891 www waterlogicdealers com Tech Portal Website canteen portal waterlogic com Waterlogic International LTD Global Headquarters Grenfell Road Maidenhead Berksh...

Page 2: ...service personnel who are experienced in the installation function and repair of this equipment This publication is written for use by these qualified individuals Waterlogic encourages users to learn...

Page 3: ...8 Electrical and Shipping Specifications 9 Operating Instructions 10 Volumetric Dispense Programming 11 Warranty 12 SERVICE GUIDE Service Requirements 13 Replacement Components Consumables 14 Drawing...

Page 4: ...perated installed or maintained The installation maintenance sanitizing and any repair must be performed by qualified persons trained by Waterlogic International or their approved distributors only Do...

Page 5: ...Household Use Never expose to direct sunlight heat sources or ambient air temperature above 37 C 100 F or below 2 C 35 F Install indoors and keep unit away from excessive humidity Never expose to fre...

Page 6: ...nt of dispense This point of dispense purification keeps the dispense nozzle free from external contamination as well as purifying the water making the freshest water possible Ice Bath Drain Port The...

Page 7: ...harmful BPA plastics NSF ANSI 55 Class A Ultraviolet Microbiological Water Treatment System NSF ANSI 372 Drinking Water System Components Lead Content This Firewall System conforms to NSF ANSI 55 Clas...

Page 8: ...int 5 C 41 F Sparkling Tank Capacity 1 Liter Ice Bath Capacity 21 Liters Recommended Service Pressure 43 60 psi 275 414 kPa Use Pressure Regulator Recommended CO2 Service Pressure 50 60 psi 345 414 kP...

Page 9: ...65 Width Depth Height w Wheels 401mm W x 590mm D x 607mm H 15 79 x 23 25 x 23 9 Weight dry 48 kg 106 pounds ELECTRICAL SPECIFICATIONS ELECTRICAL SUPPLY 120V 60Hz 15 Amp Service COMPONENT POWER approxi...

Page 10: ...d to dispense a preset volume of water and can be reprogrammed if desired One quick push Initiates dispensing of the preset volume of water Will automatically shut off once preset volume is dispensed...

Page 11: ...be flashing With a container in the dispense ready to contain the water dispensed give a short press and release of the dispense button you wish to preset Water will begin to be dispensed Once the de...

Page 12: ...ic for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date failure date and supporting installation an...

Page 13: ...sconnect before removing UV Lamp CAUTION UV LAMPS ARE HAZARDOUS Lamps are considered Hazardous Waste and must be disposed of accordingly Refer to Product MSDS sheet for details CAUTION UV SYSTEM IS FR...

Page 14: ...lation and Service Manual for additional information Surface Cleaning Clean on a regular basis with damp lint free cloth Never use harsh chemicals alcohol or acid based or abrasive agents on any part...

Page 15: ...P2 Classe Manual Page 15 Revision 3 2 2021 P2 CLASSE DRAWING AND PARTS LIST Wetted Drawing...

Page 16: ...Purezza Logo 4 ST 0241 L00 00 Classe UI Case 5 EL 0174 L00 00 Micro Switch w Lever 6 ST 0272 L00 00 Classe Micro Switch Cover 7 ST 0267 L00 00 Classe UI Hinge Stopper 8 PU 0027 L00 00 ODL Compensator...

Page 17: ...L 1293 Rubber O ring for GF Side Panel Drain Hole 19 ST 0326 L00 00 Classe Back Hole Cover 20 ST 0246 L00 00 Classe Electric Cover 21 EL 0206 L00 00 Classe Reset Filter Timer Sleep Wire 22 23 EL 5004...

Page 18: ...ob Right 32 ST 0283 L00 00 Classe Rail Bracket Sample Short Right 33 ST 0281 L00 00 Classe Rail Bracket Sample Long 34 ST 0280 L00 00 Classe Drip Tray Body Rail 35 ST 0244 L00 00 Classe Ice Bath Brack...

Page 19: ...T 0249 L00 00 Classe Fan Bracket 1 45 ST 0236 L00 00 Classe Base Plate 46 ST 0262 L00 00 Classe Pump Bracket 47 EN 0095 L00 00 Brass Vane Pump P201 and Pump Motor 120VAC 48 PU 0024 I00 00 JG Straight...

Page 20: ...0028 I00 00 Sparkling Safety Valve Kit 58 CT 0040 I00 00 Classe Sparkling Tank 59 CT 0028 L00 00 WL7 Ice Thickness Detection Probe 60 PL 0245 L00 00 Classe Bracket for Ice Probe 61 ST 0252 L00 00 Clas...

Page 21: ...L00 00 Gicar Flow Counter FMPL F L G1 4 d 3 7 71 PU 4011 JG Equal Tee Connector 1 4 72 ST 0257 L00 00 Classe Sparkling Pipe Fix Bracket 73 ST 0258 L00 00 Classe Cooling Pipe Fix Bracket 74 ST 0287 L00...

Page 22: ...itator Blade 83 ST 0253 L00 00 Classe Agitator Bracket 84 EN 0102 L00 00 ICE Bath Agitator 120V 187MM 85 ST 0266 L00 00 Classe Agitator Safety Cover 86 ST 0254 L00 00 Classe Sparkling Tank Bracket SEE...

Page 23: ...Left 96 ST 0286 L00 00 Classe Drip Tray Support Bolt 97 ST 0282 L00 00 Classe Rail Bracket Sample Short Left 98 ST 0234 L00 00 Classe Side Panel Left Purezza Logo 99 CT 2088 WL200 Firewall UV Lamp Fix...

Page 24: ...Rubber 109 PU 4028 JG Bulkhead Connector Union 1 4 x 1 4 110 PU 4031 JG LLD PE Tube Blue O D 1 4 111 PU 4010 JG Equal Straight Connector 1 4 112 PU 0021 I00 00 MS DC Solenoid Valve SWV24 02 Terminal a...

Page 25: ...22 PU 4014 JG LLDPE Tube Blue 8mm Import 123 PU 0024 I00 00 JG Straight Adaptor 8mm x 3 8 BSP 124 EN 0095 L00 00 Brass vane Pump P201 and Pump Motor 120V AC 125 PU 0024 I00 00 JG Straight Adaptor 8mm...

Page 26: ...mport 135 PU 0023 I00 00 JG Non Return Valve 5 16 136 PU 4014 JG LLDPE Tube Blue 8mm Import 137 PU 4089KR JG Equal Elbow 5 16 x 5 16 138 PU 4007 JG Reducing Elbow Connector 5 16 x 1 4 139 PU 4031 JG L...

Page 27: ...8 PU 4089KR JG Equal Elbow 5 16 x 5 16 149 PU 4014 JG LLDPE Tube Blue 8mm Import 150 PU 4007 JG Reducing Elbow Connector 5 16 x 1 4 151 PU 0021 I00 00 MS DC Solenoid Valve SWV24 02 Terminal at Inlet 1...

Page 28: ...16 x 1 4 161 PU 4066 JG Stem Elbow Connector 1 4 x 1 4 162 PU 4014 JG LLDPE Tube Blue 8mm Import 163 PU 4011 JG Equal Tee Connector 1 4 164 PU 0021 I00 00 MS DC Solenoid Valve SWV24 02 Terminal at Inl...

Page 29: ...ng 173 FW 0034 L00 00 HORECA FW Sprial Quartz Sleeve 174 PU 4031 JG LLD PE Tube Blue O D 1 4 175 PU 4008 JG Equal Elbow Connector 1 4 176 PU 0021 I00 00 MS DC Solenoid Valve SWV24 02 Terminal at Inlet...

Page 30: ...P2 Classe Manual Page 30 Revision 3 2 2021 P2 CLASSE WATER FLOW DIAGRAM...

Page 31: ...nual Page 31 Revision 3 2 2021 P2 CLASSE ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technicians should attempt...

Page 32: ...ment such as gloves and eye protection when using chemicals Refer to Material Safety Data Sheet for specific requirements of each chemical product Take all necessary precautions to prevent sanitizer f...

Page 33: ...er expose to direct sunlight heat sources or ambient air temperature above 38 C 100 F or below 2 C 35 F Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures...

Page 34: ...he Waterlogic P2 Classe and to a 120 Volt supply Turn Red Compressor Switch to the I ON position to power the unit 5 Water will begin filling the Ice Bath which will take 4 5min During this time the W...

Page 35: ...ic P2 Classe into its final operating position Be sure that a minimum of 2 clearance is maintained around both sides and the back of the P2 Classe 12 This is important to allow proper airflow and heat...

Page 36: ...prepared to catch the water or back the machine up to a sink or drain basin This operation will take upwards of 20 30min to fully drain the ice bath 5 To drain the Still water line of the P2 Classe wi...

Page 37: ...uch splash from the Sparkling dispense is experienced 1 Locate the gas blend adjustment underneath the dispense nozzle panel between the two nozzles 2 Using a wide flathead screwdriver NOT A PHILLIPS...

Reviews: