background image

 

 

 

1.  PRECAUTIONS AND 

GENERAL

 

RECOMMENDATIONS

 

 

 

SAFETY PRECAUTIONS

 

 

Connect to potable water supply:

 this system is to be used for water only and is 

not intended for use where water is microbiologically unsafe or with water of 
unknown quality without adequate disinfection. The system is not intended for 
treatment of contaminated water. 

 

Installation and maintenance:

 the installation, maintenance, sanitising and 

any repair must be performed by qualified persons trained by Waterlogic or 
their authorized distributors only. Do not remove any panels or covers unless 
qualified and competent to do so. The detachable hose-sets and the 
connection kit used to connect the main water are supplied by the technician. 
Do not reuse connectors. 

 

Indoor use only:

 Never expose to direct sunlight, heat sources, to freezing 

temperatures, ambient air temperature above 32°C (86°F) and keep the unit 
away from excessive humidity. 
 
This appliance is intended to be used in household and similar applications such as: 
staff kitchen areas in shops, offices and other working environments;  
farm houses and by clients in hotels, motels and other residential type 
environments; 
bed and breakfast type environments; 
catering and similar non-retail applications. 

 

GROUNDING INSTRUCTIONS

: This appliance must be grounded. In the event of 

a malfunction or breakdown, grounding will reduce the risk of electric shock by 
providing a path of least resistance for electric current. This appliance is 
equipped with a cord having an appliance-grounding conductor and a 
grounding plug. The plug must be plugged into an appropriate outlet that is 
installed and grounded in accordance with all local codes and ordinances. 

 

 

Use a water pressure regulator: 

Waterlogic will not be responsible for injury or damage 

caused by excessive water pressure. Input or feed pressure must be regulated to 3 bar. 
Be aware of any potential pressure surges caused by building/municipal pumping 
stations. Water block devices and external leak detectors are strongly recommended.

 

 

 

UV-C emitter (UV lamp): 

this appliance contains a UV-C emitter (UV Lamp). UV-C radiation 

may, even in little doses, cause harm to the eyes and skin. Never operate the UV-C emitter 
if damaged or removed from enclosure. Do not touch or look directly into the faucet. The 
replacement of the UV-C must be done by Waterlogic or approved Waterlogic distributors 
and with power supply disconnected. The UV lamp must be replaced at 6 month intervals 
or when necessary.

 

 

Do not operate if damaged:  

If the machine or supply cord is damaged, it must be 

replaced by the manufacturer, its service agent or similarly qualified persons in 
order to avoid a hazard. 

 

 
 

Ensure all local laws and codes including health and safety guidelines are met when installing this 
Waterlogic purification system. Only qualified service technicians should attempt installation and 
service. Always read the entire operating instructions before using the appliance and save these 
instructions for future use.

 

 

WARNING Improper connection of the appliance-grounding conductor can result in a risk of 
electric shock. Check with a qualified electrician or service representative if you are in doubt 
whether the appliance is properly grounded. Do not modify the plug provided with the 
appliance; if it will not fit the outlet, have a proper outlet installed by a qualified technician

 

!

 

Summary of Contents for PUREZZA CLASSE

Page 1: ...PUREZZA CLASSE BASE CABINET ...

Page 2: ...d and qualified personnel Products manufactured and marketed by Waterlogic and its affiliates are protected by patents Waterlogic International Limited and WLI Trading Limited reserve the right in order toreflectcontinuousresearchanddevelopment toamendor changespecifications without prior notice Waterlogic and the Waterlogic logo Firewall and the Firewall logo are trademarks in countries where the...

Page 3: ...2 TABLE OF CONTENTS 1 PRECAUTIONS AND GENERAL 3 2 PRODUCTINFORMATION 5 3 INSTALL AND ASSEMBLY 7 ...

Page 4: ...plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances Useawaterpressureregulator Waterlogicwillnotberesponsibleforinjuryordamage caused by excessive water pressure Input or feed pressure must be regulated to 3 bar Beawareofanypotentialpressuresurgescausedbybuilding municipalpumping stations Water block devices and external leak detector...

Page 5: ...f damage to the supply cord The appliance is to only be used with the power supply provided with the appliance Electrical shock hazard Always use a dedicated and properly earthed outlet Unit should be protected by residual current device RCD having a rated residual operating current not exceeding 30 mA Use only Waterlogic supplied power cord Never use extension cords or power strips to connect uni...

Page 6: ...ORMATION PUREZZA CLASSE BASE CABINET 2 1 CONTENTS Item No Image Description 1 Rubber Feet 2 Down Panel 3 Bottom Hinge Top Hinge 4 Side panel L R 5 Middle Shelf 6 Top Shelf 7 Back Panel 8 Front Panel 1 2 3 4 4 3 5 6 7 ...

Page 7: ...6 2 2 TECHNICAL INFORMATION Physical Dimensions WxDxH mm 400mm W X 590mm D X 824mm H Weight net kg 4 2kg TECHNICALDATA CLASSE BASE CABINET ...

Page 8: ...nstalled on the unit they must be removed for the unit to seat properly onto the base cabinet Those wheels may be transferred to the base cabinet if desired for easier mobility Removing and reinstalling the caster wheels onto the base cabinet will require the use of a 14mm thin profile wrench pictured below Ensure all local laws and codes including health and safety guidelines are met when install...

Page 9: ...s you on the right hand side Locate the left hand panel item 4 page 5 and screw to the down panel as per below image 3 Locate the middle and top shelf items 5 and 6 from page 5 and carefully screw each shelf to the left hand panel gently support the shelf as you screw the shelf to the left hand panel ...

Page 10: ...panel Item 4 page5 and screw the right hand panel to the down panel middle shelf and top shelf 5 Locate the rear panel item 7 page 5 for the base cabinet It may be easier to lay the base cabinet on its front carefully screw the back panel to the rear of the base cabinet as per the below image ...

Page 11: ...age 5 and rest the top panel against the base cabinet Locate the top hinge and slot this into the top panel Screw the top hinge to the base cabinet and ensure the door opens and closes freely 7 Carefully clean all the panels of the base cabinet ensuring any hand or finger marks have been removed It is recommended to use S11 Aquadosa spray to ensure all bacteria has been removed from the base cabin...

Page 12: ...r Suite 4 Beacon Court Sandyford Co Dublin Ireland WLI UK LTD info waterlogic ie Waterlogic International LTD Global Headquarter 1 Grenfell Road Maidenhead Berkshire SL6 1HN United Kingdom For technical support Email support waterlogicsupport zendesk com ENGINFW 04 12 19 ...

Reviews: