background image

The Cube Technical Manual - Version 1, May 2014

18

19

4.

 Remove the top cover from the Cube by undoing the two screws located at the 

back of the machine, then slide the panel backwards and lift up.

5. 

Take out the filter by un-clicking the loop at the top of the housing and pulling it 

in an upward motion. If there are two filters in the machine then both of these need 

to be removed. 

6.

 Unscrew the filter housing(s) and remove the filter cartridge, place this to one 

side as this will need to be re-fitted this once you have completed the sanitising 

procedure.

7.

 Measure 40ml of Aqua Dosa sanitising fluid into one of the empty filter housings 

and securely fasten the filter head. Re-fit the filter(s) into the machine pushing it 

firmly into place.

8.

 Replace the top cover and re-connect the power lead, then turn on the red switch 

at the rear of the machine. Turn the water supply back on.

9.

 Dispense cold water until the sanitisation fluid leaves the faucet, this can be 

checked by dispensing cold water until the colour of the test strip has changed to 

indicate the presence of the sanitisation fluid (Normally about 400-500ml of water 

needs to be dispensed). Do not let any sanitisation fluid enter the hot tank.

10.

 Leave the sanitisation fluid inside the machine for a minimum of 10-15 minutes, 

when this time has been reached, flush water through the machine until there is 

no sanitisation fluid left inside. You can use your test strips to check that all of the 

sanitisation fluid has been effectively flushed out.

11.

  Turn off the water supply to the machine and release the internal pressure by 

selecting the cold option until the water stops being dispensed. Isolate the power to 

the machine by switching the red switch at the rear of the machine off and removing 

the power lead. 

12.

 Remove the top cover from the machine and take out the filter(s) and unscrew 

the filter housing, pour the excess water down the drain and re-fit the cartridge.

13.

 Re-fit the filter(s) into the machine, pushing it firmly into place. Replace the top 

cover and re-connect the power lead, then turn on the red and green switches at 

the rear of the machine. Turn on the water supply.

14.

 Select the hot icon, then select and hold the main dispense button immediately 

after selecting the hot icon

15. 

Dispense at least 200ml of hot water

16. 

The machine will now begin to heat/ chill the water

17.

 Inspect the faucet nipple and clean or replace if it is damaged or if there any 

calcium built up around it.

18. 

Using the antibacterial wipes, sufficiently clean the exterior panels of the 

machine, including the drip tray and grill.

DE-SCALING

You will need the following items:

•  A Phillips screwdriver

•  A pair of rubber gloves

•  De-scale solution or powder

•  A funnel or large syringe

•  A container that can hold 5 litres

•  Non-abrasive anti-bacterial wipe or cloth

1.

 Put on the rubber gloves to minimise the chance of any contamination to the 

machine and to protect yourself whilst the de-scaling procedure is being carried 

out.

2.

 Allow the machine to heat the water up to normal operating temperature, as the 

water inside the tank needs to be hot for the de-scaling solution to work effectively.

3.

 You will need to stop the water supply to the machine by turning the isolation 

valve to the off position and releasing the pressure by selecting the cold water 

option until the water stops being dispensed.

4. 

Isolate the power to the Cube by turning the red and green power switches off, 

these are located at the rear of the machine. Remove the power lead as a second 

safety precaution. 

5.

 Remove the top cover from the Cube by undoing the two screws located at the 

back of the machine, then slide the panel backwards and lift up.

6.

 Take out the filter by un-clicking the loop at the top of the housing and pulling it 

in an upward motion. If there are two filters in the machine then both of these need 

to be removed. 

7.

 Unscrew the filter housing(s) and remove the filter cartridge, place this to one 

side as this will need to be re-fitted this once you have completed the de-scaling 

procedure.

8. 

Drain 50-100ml of hot water from the machine into one of the empty filter housings, 

using the drainage valve at the rear of the machine. Then use this hot water from the 

machine to make your de-scaling solution, following the manufacturer’s instructions 

of the descaler. Re-assemble the filter housing with the de-scale solution inside.

9.

 Re-fit the filter(s) into the machine pushing it firmly into place. Replace the top 

cover and re-connect the power lead, then turn on the red switch at the rear of the 

machine. Turn the water supply back on.

10.

 Place your container under the dispense area and flush through 500ml of hot 

water. Allow the solution to remain in the tank for 5 – 10 minutes.

11. 

Turn off the water supply to the machine and release the internal pressure by 

Summary of Contents for WL Cube Firewall

Page 1: ...WL Cube Firewall Technical Manual VERSION 1...

Page 2: ...10 The appliance is to be supplied through a residual current device RCD having a rated residual operating current not exceeding 30mA 11 This appliance is intended to be used in household and similar...

Page 3: ...any kinds of different filter combinations available from Waterlogic to suit local water conditions FIREWALL CHAMBER The Firewall chamber incorporates the in Faucet UV and is made of aluminium and is...

Page 4: ...the quartz spiral cleaned by using an ultrasonic bath if needed PCB The PCB Printed Circuit Board is the control unit for the Cube it is responsible for the functions of all the mechanical and electri...

Page 5: ...a trip hazard Keep them off the floor Take care not to allow the power lead to get wet If the lead gets wet it must not be used The Cube Technical Manual Version 1 May 2014 WL Cube Flow Diagram Cold...

Page 6: ...rocedures 1 Mount the Cube on a firm level surface so the machine cannot topple or fall over A 50mm air gap is required the whole way around the machine to allow for sufficient ventilation The Cube mu...

Page 7: ...The Cube should be sanitized at installation INSTALLATION KIT The Cube must be installed according to the local guidelines and it is advised that an installation kit be used A pressure reducing valve...

Page 8: ...Always place cup mug in the centre of the drip tray Always use a ceramic cup or a cup suitable for use with hot water Do not hold cup or place hands in dispensing area whilst dispensing water Do not...

Page 9: ...if there is any visible remove the loom and replace with a new one 9 Reconnect and replace the UV lamp assembly making sure not to touch the new UV lamp with bare hands as this will shorten the life...

Page 10: ...16 The machine will now begin to heat chill the water 17 Inspect the faucet nipple and clean or replace if it is damaged or if there any calcium built up around it 18 Using the antibacterial wipes su...

Page 11: ...panels of the machine including the drip tray and grill ADVISORY ICONS HOT WATER Press and hold the hot water icon for 3 seconds until the icon has illuminated orange select the dispense button and ho...

Page 12: ...rrectly and being turned on and off when you select the cold option 5 There is cold water flow but hot water is not flowing This may be due to calcium build up in the hot tank or the hot water outlet...

Page 13: ...t and continual improvement and therefore reserves the right to change specifications without prior notice other than in the case of significant changes Description Cube 120V HCA Cube 230V HCA Machine...

Page 14: ...into the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory to show its ability to inhibit the g...

Page 15: ...rsion 1 May 2014 28 29 Electrical Wiring Diagram 230V Dip Switch Setup DANGER HIGH VOLTAGES PRESENT ON THIS PCB CARE MUST BE TAKEN WHEN LIVE TESTING THE CUBE MAIN PCB DIP SWITCHES 1 2 WITH INSTRUCTION...

Page 16: ...ERATURE SETTING Cold water temp range 5 c 10 c 15 c When reading this document please note the white coloring on the diagrams indicate the required position of the switch to determine the setting UV 1...

Page 17: ...Blue O D 1 4 13 JG Equal Tee Connector 1 4 14 JG Equal Elbow Connector 1 4 15 JG LLD PE Tube Blue O D 1 4 16 Solenoid Valve 24 DC Single Spring Load 17 JG Stem Elbow Connector 1 4 1 4 18 Drain valve...

Page 18: ...nector 1 4 36 JG LLD PE Tube Blue O D 1 4 37 JG LLD PE Tube Blue O D 1 4 38 Solenoid Valve 24 DC Single Spring Load 39 JG Equal Tee Connector 1 4 40 JG Stem Elbow Connector 1 4 1 4 41 JG Equal Tee Con...

Page 19: ...stem Elbow connector 15 Solenoid Valve 24 DC Single Spring Load 16 Cube cold tank 1 4 Litre 17 Compressor 18 Domestic Filter Dryer Chinese 19 WL Cube Side panel right Silver 20 BulkHead Fitting 1 4 x...

Page 20: ...use WL Label 37 Hot Cold Solenoid Valve 24V 300mm CUBE 38 1 4 Equal Tee Connector ST 39 UV 15 W Electronic Ballast Ver 3 40 Power Transformer 41 WL Cube Electronics cover Black 42 WL Cube UI Label WL...

Page 21: ...eacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 11710 Stonegate Circle Omaha NE 68164 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA...

Reviews: